Clinical In-hospital Evaluation of the Usefulness of a New Multi-detector Computed Tomography Scanner From Arineta Ltd

Clinical In-hospital Evaluation of the Usefulness of a New Multi-detector Computed Tomography Scanner From Arineta Ltd

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02616939
Acronym
Arineta
Enrollment
400
Registered
2015-11-30
Start date
2016-01-31
Completion date
2022-11-30
Last updated
2016-03-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Keywords

Multidetector computed tomography

Brief summary

Clinical evaluation of a new cardiovascular oriented CT scanner from Arineta Ltd.

Detailed description

The study will evaluate a new twin source relatively compact CT scanner with advanced technology which is optimized for cardiovascular imaging. Eligible patients with a clinical indication will undergo coronary or cardiac CT scans using the new SpotLight CT from Arineta Ltd. Image quality and usefulness of the new system will then be evaluated.

Interventions

OTHERCardiac CT scanning (with the SpotLight CT)

Cardiac CT scanning

Sponsors

Arineta Ltd.
CollaboratorINDUSTRY
Carmel Medical Center
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 100 Years
Healthy volunteers
No

Inclusion criteria

1. Symptomatic patients with a clinical indication for cardiac CT 2. Patients with a clinical indication for CT 3. Estimated GFR \> 60 mL/min

Exclusion criteria

1. No clinical indication for CT scanning 2. Contra-indication for CT scanning or for IV contrast administration 3. Pregnancy 4. Inability to give an informed consent

Design outcomes

Primary

MeasureTime frameDescription
Image quality (subjective) of the new SpotLight CT scanner from Arineta Ltd.2 yearsSubjective (4 grade scale) image quality assessment of coronary arteries. unassessable studies and unassessable coronary segments will be reported.
Image quality (objective) of the new SpotLight CT scanner from Arineta Ltd.2 yearsImage contrast, image noise, signal to noise ratio and contrast to noise ratio. Those numerical values will be reported to allow comparisons with values previously reported with other CT scanners.

Secondary

MeasureTime frameDescription
Diagnostic accuracy of the new SpotLight CT scanner from Arineta Ltd.2 yearsPerformance characteristics of the new CT scanner for diagnosing obstructive coronary artery disease as compared to other reference standards such as invasive coronary angiography.
The effect of cardiac CT results (with SpotLight CT) on patients triage5 yearsThe effect of cardiac CT results on patients diagnosis and therfore hospitalization or discharge decisions
The predictive value of cardiac CT results (with SpotLight CT) for patients outcome5 yearsPredictive value of cardiac CT results for adverse outcomes (death/myocardial infarction/revascularization).

Countries

Israel

Contacts

Primary ContactRonen Rubinshtein, MD
ronenrub@clalit.org.il+972-4-8250153
Backup ContactMali Azencot, PHD-RN
maliaz@clalit.org.il+972-4-8250844