Skip to content

Duodenoscope Disinfect Study

Prospective Randomized Double-blinded Trial Comparing Three Duodenoscope High- Level Disinfection and Sterilization Procedures

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02611648
Enrollment
541
Registered
2015-11-23
Start date
2015-11-30
Completion date
Unknown
Last updated
2017-03-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Endoscopic Retrograde Cholangiopancreatogram (ERCP)

Brief summary

This study is investigating the most effective way to sterilize duodenoscopes (scopes) used at Beth Israel Deaconess Medical Center (BIDMC). Right now, BIDMC uses the standard method of high level disinfection to sterilize scopes. Because infections have been passed by scopes at other institutions in the U.S., the investigators are exploring whether or not adding two different sterilization processes will reduce this risk of contamination. Bacteria may be passed from a patient's intestines to the scope. Or, if the scope is contaminated, bacteria may be passed from the scope to the patient. In order to understand how bacteria are passed, the investigators will be taking samples of the patient's intestinal bacteria to compare to the bacteria, if any, found on the scope.

Detailed description

Study Design This study is designed to evaluate the effect of supplementing standard high-level disinfection with additional high level-disinfection or sterilization procedures on the frequency of duodenoscopes contamination. Duodenoscopes will be randomly assigned to one of three arms: * Standard high-level disinfection currently performed at BIDMC (standard HLD) * Standard high-level disinfection with an additional exposure time to disinfectant (double HLD) * Standard high-level disinfection followed by ethylene oxide (HLD/ETO) The study will be conducted with the following elements: 1. All duodenoscopes will be randomly assigned to a study arm before the duodenoscope is used for an Endoscopic Retrograde Cholangiopancreatogram (ERCP) procedure included in the study, including duodenoscopes introduced during the study. 2. All duodenoscopes used for ERCP will have the following cultures obtained in a sterile fashion 3. Patient study consent for obtaining patient rectal surveillance and clinical cultures will be obtained at the time of ERCP procedure consent among all patients undergoing ERCP. Patients will be blinded to duodenoscope disinfection/sterilization assignment. 4. The ERCP procedure will be performed according to standard clinical practice. Among patients consenting to specimen collection, a duodenal aspirate will be obtained during the procedure. 5. Among consenting patients, a rectal surveillance swab will be collected post-procedurally by ERCP staff. 6. After ERCP completion, current BIDMC-employed trained technicians will perform the assigned disinfection/sterilization procedure.

Interventions

OTHERDouble HLD

Standard high level disinfectant (metricide ortho-phthalaldehyde) with an additional exposure time to disinfect

OTHERHLD/ETO

Standard high level disinfectant (metricide ortho-phthalaldehyde) followed by ethylene oxide

Sponsors

Beth Israel Deaconess Medical Center
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
QUADRUPLE (Subject, Caregiver, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. A duodenoscope used for any intended ERCP procedure will be included in the study 2. All adult patients (age ≥18 years) scheduled to undergo ERCP will be offered participation in patient specimen collection component of the study

Exclusion criteria

1. Patients in whom ERCP or endoscopy with a duodenoscope is medically contra-indicated will not be included in the patient specimen collection portion of the study 2. Patients with surgically altered anatomy in whom ERCP is performed using an enteroscope (and not a duodenoscope) will not be included in the study

Design outcomes

Primary

MeasureTime frameDescription
Frequency of contaminated duodenoscopes after using three different types of disinfection processes6 monthsCompare the frequency of duodenoscope contamination after reprocessing using 3 different methods: standard high-level disinfection procedure with ortho-phthalaldehyde (standard HLD), double cycle of standard high-level disinfection (double HLD), and standard high-level disinfection followed by ethylene oxide (ETO) gas sterilization (HLD/ETO)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 9, 2026