Comparison of In-the-bag Stability Between Single-piece and Three-piece Intraocular Lens

Comparison of In-the-bag Stability Between Single-piece and Three-piece Intraocular Lens Via Scheimpflug Imaging System

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02609997
Enrollment
65
Registered
2015-11-20
Start date
2012-09-30
Completion date
2012-12-31
Last updated
2015-11-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract

Keywords

Intraocular lens

Brief summary

Rapid advances of cataract surgery techniques and intraocular lens (IOL) technology have enabled the transition of cataract surgery from blindness relief to refractive correction. An ideal IOL is the critical component to achieve the refractive target of cataract surgery. Biocompatibility, rate of posterior capsule opacification (PCO) and visual quality have all been suggested as the critical factors of an ideal IOL and widely investigated. Recently, stability of IOL position has also been suggested as one of those critical factors due to its close correlation with postoperative visual function. Data suggests that IOL forward movement of 0.29 mm along the visual axis is associated with -0.4D myopic shift. Wang and colleagues recently reported that 0.5mm decentration of an aspheric IOL could eliminate its aberration-correcting effect. Poor stability could even lead to IOL exchange, an additional surgery that put both surgeons and patients in pain. As the supporting element of an IOL, the haptics are crucial to keep the IOL in place. Various haptic designs are being compared in terms of position stability of IOLs. Haptic designs of single-piece versus 3-piece are often compared because they are currently the most commonly used types. Single-piece IOLs have soft and broader haptics which are made of the same material as the optic, usually hydrophobic or hydrophilic acrylic, whereas 3-piece IOLs have rigid haptics which are made of poly methyl methacrylate (PMMA). Clinical studies comparing these haptic designs have yielded controversial results regarding their position stability in the capsular bag, which is the most recommended site for IOL fixation in an uneventful cataract surgery.

Detailed description

Rapid advances of cataract surgery techniques and intraocular lens (IOL) technology have enabled the transition of cataract surgery from blindness relief to refractive correction. An ideal IOL is the critical component to achieve the refractive target of cataract surgery. Biocompatibility, rate of posterior capsule opacification (PCO) and visual quality have all been suggested as the critical factors of an ideal IOL and widely investigated. Recently, stability of IOL position has also been suggested as one of those critical factors due to its close correlation with postoperative visual function. Data suggests that IOL forward movement of 0.29 mm along the visual axis is associated with -0.4D myopic shift. Wang and colleagues recently reported that 0.5mm decentration of an aspheric IOL could eliminate its aberration-correcting effect. Poor stability could even lead to IOL exchange, an additional surgery that put both surgeons and patients in pain. As the supporting element of an IOL, the haptics are crucial to keep the IOL in place. Various haptic designs are being compared in terms of position stability of IOLs. Haptic designs of single-piece versus 3-piece are often compared because they are currently the most commonly used types. Single-piece IOLs have soft and broader haptics which are made of the same material as the optic, usually hydrophobic or hydrophilic acrylic, whereas 3-piece IOLs have rigid haptics which are made of poly methyl methacrylate (PMMA). Clinical studies comparing these haptic designs have yielded controversial results regarding their position stability in the capsular bag, which is the most recommended site for IOL fixation in an uneventful cataract surgery. Most previous studies measure the IOL position based on Purkinje reflections. The measurement is time-consuming and patients are reluctant to cooperate during image acquisition. Purkinje measurement does not detect anterior chamber depth (ACD) and as such cannot reveal the IOL position along the axis. Clinical Scheimpflug systems based on rotating Scheimpflug imaging, on the other hand, is able to acquire sufficient 3-dimensioinal data points within a reasonably short period, usually seconds. It was shown that these systems are one of the best methods to estimate IOL position. To better compare the intracapsular stability between single-piece and 3-piece IOLs, the investigators measured IOL positions with rotating Scheimpflug imaging systems and tested the visual quality of patients implanted with these IOLs.

Interventions

PROCEDUREPhacomulsification lens removal cataract surgery with single-piece Intraocular lens(IOL) implantation

The phacoemulsification lens removal cataract surgery is performed with single-piece IOL.During Phacoemulsification.

PROCEDUREPhacomulsification lens removal cataract surgery with three-piece Intraocular lens(IOL) implantation

The phacoemulsification lens removal cataract surgery is performed with three-piece IOL.During Phacoemulsification.

DRUGSubconjunctival dexamethasone

All patients received subconjunctival dexamethasone (2 mg) during surgery. Topical anesthesia, consisting of a single drop of 0.5% proparacaine (Alcaine, Alcon Laboratories), was administered three times at intervals of 5 minutes prior to surgery

viscoelastic materials are used to protect corneal endothelial cells

0.5% proparacaine (Alcaine, Alcon Laboratories)

Sponsors

Sun Yat-sen University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
60 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

* diagnosis of bilateral age-related cataract and age between 60 to 85 years

Exclusion criteria

* vision-impairing diseases other than cataract, severe refractive error (Preoperative spherical equivalent of either eye \>-6.00D or +5.00D) * history of ocular trauma, past refractive surgery or other ophthalmic surgery, capsular or zonular disorders that might affect the post-operative centration of IOLs * surgical complications including severe hyphema, iris injury, repeated IOL implantation * unable to achieve in-the-bag implantation of IOL, corneal sutures during surgery

Design outcomes

Primary

MeasureTime frame
The grade of in-the-bag stability between single-piece intraocular lenses (IOLs) and three-piece intraocular lenses(IOLs)3 months after the surgery

Secondary

MeasureTime frame
The visual acuity between single-piece intraocular lenses (IOLs) and three-piece intraocular lenses(IOLs)3 months after the surgery