Diversion-p64 Post Market Clinical Follow-Up Study to Assess Safety and Effectiveness of the p64 Flow Modulation Device

Prospective, Multicenter, Single Arm Post Market Clinical Follow-Up Study to Assess Safety and Effectiveness of the p64 Flow Modulation Device

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02600364
Enrollment
450
Registered
2015-11-09
Start date
2015-12-31
Completion date
2020-06-30
Last updated
2020-11-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intracranial Aneurysm

Keywords

Aneurysm, intracerebral, stroke, p64

Brief summary

The purpose of this study is to assess safety and effectiveness of the p64 Flow Modulation Device.

Detailed description

Title: Diversion-p64. Device: p64 Flow Modulation Device. Study design: Prospective, multicenter, single arm Post Market Clinical Follow-Up Study. Purpose: To assess safety and effectiveness of p64. Study duration: 48 months. Sample Size: 400 patients. Number of sites: \> 20. Follow-up intervals: Two independent follow-ups (after 3-6 and 7-12 months) according to site specific standard.

Interventions

None listed

Sponsors

Phenox GmbH
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Age ≥ 18 2. Patient harbours either one saccular or one dissecting or one blisterlike or one fusiform intracerebral aneurysm or one intracerebral segmental disease, in the anterior circulation for which the indication for p64 treatment is given 3. Patient or legal representative provides written informed consent verifying that he/she consents to the use of his/her data (according to the data protection laws)

Exclusion criteria

1. Aneurysms of the posterior circulation 2. Imaging evidence of bifurcation aneurysms 3. Imaging evidence of dissections 4. Imaging evidence of fistulae 5. Imaging evidence of arteriovenous malformations 6. Patient is harbouring another aneurysm that has to be treated within six months after first procedure 7. Known allergy to study medication, e.g. ASA, Clopidogrel, Heparin or contrast media 8. Confirmation of positive pregnancy test according to site specific standard of care (e.g. test, verbal communication) 9. Current involvement in another study or trial 10. Parent vessel treated with other Flow Diverters than p64 during intervention and re-treatment

Design outcomes

Primary

MeasureTime frameDescription
Change in the rate of complete occlusionimmediately after treatment, an expected average of 1 hour; to 12 monthsRate of complete aneurysm occlusion is assessed immediately after treatment (an expected average of 1 hour) and at both follow-up visits (3-6 months and 7-12 months). The change is assesed.
Change of frequency of major stroke (ischemic or hemorrhagic) or neurological death related to the treatment of the target aneurysmimmediately after treatment, an expected average of 1 hour; to 12 monthsFrequency of major stroke (ischemic or hemorrhagic) or neurological death is assessed immediately after treatment (an expected average of 1 hour) and at both follow-up visits (3-6 months and 7-12 months). The change is assesed.

Secondary

MeasureTime frameDescription
Intra-procedural technical complicationsduring treatment, an expected average of 1 hourp64 placed in the desired location Correct opening of p64 (markers fully deployed) at the end of the procedure Ability to detach p64 at the end of the procedure
Change of Angiographic resultsimmediately after treatment, an expected average of 1 hour; to 12 monthsChange in both Rate of re-growth (related rate of re-treatment) and Rate of recanalization (related rate of re-treatment) are assessed immediately after treatment (an expected average of 1 hour) and at both follow-up visits (3-6 months and 7-12 months).
Intra-procedural vascular complicationsduring treatment, an expected average of 1 hourVessel perforation (e.g. with distal wire tip of p64, microcatheter) Target aneurysm perforation (e.g. with distal wire tip of p64, microcatheter) Thromboembolism Dissection of any access vessel Side branch occlusion
Post-procedural Complications3-6 and 7-12 monthsParenchymal hemorrhage detected during the follow-up period Subarachnoid hemorrhage detected during the follow-up period Ischemic stroke detected on follow-up imaging Rupture of the target aneurysm detected during the follow-up period Rate of in-stent-stenosis detected during the follow-up period

Countries

Argentina, Belgium, Bulgaria, France, Germany, Italy, Poland, Romania, Russia, United Kingdom

Outcome results

None listed