Use of a Shear Reduction Surface in Pre-hospital Transport

Use of a Shear Reduction Surface in Pre-hospital Transport

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02591641
Enrollment
30
Registered
2015-10-29
Start date
2015-11-30
Completion date
2016-11-30
Last updated
2017-03-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Shear Strength

Keywords

pre-hospital transport, shear force, tissue interface pressure

Brief summary

The purpose of this study was to examine the effectiveness of a shear reduction surface on shear, pressure, and comfort used in pre-hospital ground transport.

Detailed description

This study enrolled healthy adult volunteers of any race or gender, stratified into 3 Body Mass Index (BMI) categories (≤20, 20.1-24.9, ≥25), who served as their own controls. The setting for this study was on a closed driving course utilized for training of emergency and law enforcement personnel, and the vehicle used was a standard ground ambulance affiliated with the Medical Transport of a tertiary medical center. Apparatus and/or instruments: A commercial full-length LiquiCell® anti-shear mattress overlay (ASMO) (Birchwood Laboratories, Eden Prairie MN) was placed on the standard ambulance stretcher mattress. Shear force and tissue interface pressure was measured during a full stop, acceleration, travelling at 30 mph, deceleration, and a full stop by a PREDIA device (Molten Corporation, Hiroshima Japan) through reusable sensors attached to the sacrum, ischial tuberosity, and heel. Procedures: Following written informed consent, subjects were weighed and measured with a calibrated scale to calculate a current BMI. Three PREDIA sensors were secured to three sites (sacrum, ischial tuberosity, and heel) with double-stick tape. Subjects wore standard hospital scrub bottoms, and were secured supine to the ambulance stretcher using standard procedure. Subjects were blinded to the presence of the LiquiCell® ASMO overlay by a sheet covering on the stretcher. The ASMO was placed according to a simple randomization table. The stretcher was initially be placed with 0 degree head-of-bed (HOB) elevation, followed by subsequent HOB elevations of 15 degrees and 30 degrees. HOB elevations were verified using a standard goniometer. The ambulance traveled over a closed course driven by ambulance staff members that had passed the mandatory Coaching the Emergency Vehicle Operator (CEVO) driving course. The course included at maximum speed of 30 mph and 5 complete stops at each of 3 HOB elevations (0, 15, and 30 degrees). Shear measurements (measured in Newtons) and pressure measurements (measured in mmHg) for each anatomical site were taken with the PREDIA sensors during a full stop, acceleration, travelling at 30 mph, deceleration, and a full stop for each run. At the beginning and completion of each set of 5 runs, subjects were asked to rate their discomfort on a scale of 0 (no discomfort) to 10 (worst discomfort imaginable). Following the first set of 15 runs, the course was repeated with or without the LiquiCell® ASMO according to the randomization table.

Interventions

OTHERStandard of Care

Standard ambulance stretcher mattress

DEVICEAnti-shear mattress overlay

A commercial full-length LiquiCell® anti-shear mattress overlay (ASMO) was placed on the standard ambulance stretcher mattress.

Sponsors

Mayo Clinic
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
SUPPORTIVE_CARE
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
Yes

Inclusion criteria

* Healthy adult volunteers * 18-70 years old * Able to read and write English * Height of 6' feet tall or less * Weight under 300 lbs.

Exclusion criteria

* Non-English speaking * Pregnancy * Prisoners * Previous history of pelvic fracture, pressure ulcers on sacrum, ischial tuberosity, or heel * Adhesive allergy or sensitivity * Height over 6 feet tall * Weight over 300 lbs.

Design outcomes

Primary

MeasureTime frameDescription
Change in Shear Force as as measured by the PREDIA monitorbaseline, 2 hoursThe PREDIA monitor is a hand-held monitor that measures both shear forced (measured in Newtons) and tissue-interface pressure (measured in mmHg) simultaneously at discrete points in time.

Secondary

MeasureTime frameDescription
Change in Tissue-Interface Pressure as measured by the PREDIA monitorbaseline, 2 hoursThe PREDIA monitor is a hand-held monitor that measures both shear forced (measured in Newtons) and tissue-interface pressure (measured in mmHg) simultaneously at discrete points in time.
Change in Comfort Scorebaseline, 2 hoursAt the beginning and completion of each set of 5 runs, subjects were asked to rate their discomfort on a scale of 0 (no discomfort) to 10 (worst discomfort imaginable).