Healthy
Conditions
Keywords
fructose, metabolism, acute
Brief summary
The purpose of this study is to investigate the metabolic and endocrine responses during 3 hour after taking 75g fructose or glucose in young Chinese.
Detailed description
The study was a double-blinded, randomized, crossover trial. Twenty healthy volunteers were randomized to two groups: group A (300ml of 22.5% glucose) and group B (300ml of 22.5% fructose).Volunteer was randomized into either group A or B, after an 8-h overnight fasting, took 300ml of solution at 0830 within 5 minutes. After one-week washout period, volunteer was crossed over for either group B or A. each intervention, venous blood was collected at 0h, 0.5h, 1h, 2h, and 3h and blood pressure was tested at 0h, 1h, 2h, and 3h.
Interventions
75g fructose is dissolved in 300 ml water.After overnight fasting, 300ml of solution at 0830 within 5 minutes is taken by volunteers
75g glucose is dissolved in 300 ml water.After overnight fasting, 300ml of solution at 0830 within 5 minutes is taken by volunteers
Sponsors
Study design
Eligibility
Inclusion criteria
* Inclusion criteria were aged 19-39 years, with BMI between 18-24 kg/m 2.
Exclusion criteria
* Subjects pregnant or having a history of hepatic or renal disease, fructose intolerance, gout, hypoglycemia, or diabetes mellitus were excluded. * Subjects taking any drugs, botanicals, or nutraceutical known to influence blood pressure also were rejected either.
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| serum uric acid | 3 hours | Serum uric acid concentration was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by DiaSys Diagnostic Systems (Shanghai) Co., Ltd |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| blood pressure | 3 hours | Blood pressure was measured at Zhejiang University Hospital by the research workers who were blind to the groups within 3 hours blood collection. |
Other
| Measure | Time frame | Description |
|---|---|---|
| aldose reductase | 3 hours | Enzymatic activity of aldose reductase in serum was measured using ELISA kit (Shanghai Changjin Biology Co., Lte., Shanghai, China ) by the research workers who were blind to the groups. |
| phosphofructokinase | 3 hours | Enzymatic activity of phosphofructokinase in serum was measured using ELISA kit (Shanghai Changjin Biology Co., Lte., Shanghai, China ) by the research workers who were blind to the groups . |
| insulin | 3 hours | Serum insulin concentration was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd |
| insulin-c | 3 hours | Serum insulin-c concentration was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd |
| serum glucose | 3 hours | Serum glucose level was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd |
| total cholesterol | 3 hours | Total cholesterol concentration was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd |
| high-density cholesterol | 3 hours | High-density cholesterol was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd. |
| low-density cholesterol | 3 hours | Low-density cholesterol concentration was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd. |
| lactate dehydrogenase | 3 hours | Enzymatic activity of lactate dehydrogenase was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd. |
| triglyceride | 3 hours | Triglyceride concentration in serum was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd |
| nitric oxide | 3 hours | Serum nitric oxide concentration was measured using NO assay kit (Nanjing Jiancheng Technology Co., Lte., Nanjing, China) by the research workers who were blind to the groups. |
Countries
China