Skip to content

REFIT Hearing: Remote Fitting of Hearing Aids

REFIT Hearing: Remote Fitting of Hearing Aids

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02589561
Acronym
REFITHEARING
Enrollment
60
Registered
2015-10-28
Start date
2015-10-31
Completion date
2016-12-31
Last updated
2018-05-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hearing Loss

Keywords

hearing loss, hearing aids

Brief summary

Currently, the fitting of hearing aids is using a computer interface that allows to adjust the gain and compression of acoustic amplification. This adjustment is made face to face, patient and audiologist being located in a soundproof space to test the effectiveness of the hearing aid. However, advances in telemedicine in this context, let consider the possibility of addressing these hearing aids fitting via the same computer interface, but remotely controlled by the hearing care professional. The purpose of this study is to assess the ability to perform these tests no longer in front of the patient settings, but away from it, and without visual and sound contact other than through a computer interface. At the end, this project wants to show that a remote fitting is an acceptable procedure that provides comparable results to-face fitting in terms of speech perception, speech in noise audiometry, hearing loss related quality of life in order to be able to offer this type of strategy.

Detailed description

1. Background and rationale: Currently, the fitting of hearing aids is using a computer interface that allows to adjust the gain and compression of acoustic amplification. This adjustment is made face to face, patient and audiologist being located in a soundproof space to test the effectiveness of the hearing aid. However, advances in telemedicine in this context, let consider the possibility of addressing these hearing aids fitting via the same computer interface, but remotely controlled by the hearing care professional. The purpose of this study is to assess the ability to perform these tests no longer in front of the patient settings, but away from it, and without visual and sound contact other than through a computer interface. 2. Objectives Main objective: To show that the remote fitting of hearing aids using the platform developed by AudioProConnect provides speech perception scores similar to those obtained by a face-control, after 5 weeks of use among experienced hearing aid users. Secondary Objectives: To compare the duration and the quality of both types of fitting, speech in noise testing, deafness related quality of life and assess the wearing time of hearing aids. 3. Methods DESIGN: Biomedical research on health product, prospective, multicenter, randomized, and crossover study to assess the remote fitting of hearing aids: Study REFIT-HEARING Study Population: adults with bilateral hearing aids. Inclusion criteria: Patient aged between 18 and 85 years old, with hearing loss and using two hearing aids for more than one year, and compatible with AudioProConnect platform. Exclusion criteria: Patient with fluctuations of pure tone audiometry, cognitive disorders or severe speech disorders. Patient unable to move in an audiology laboratory. Primary Outcome: Evaluation of speech perception score with PBK test free-field at 60 dB. Secondary endpoints: assessment of quality control by measuring the pitch gain, duration of fitting in minutes, speech in noise audiometry, the wearing time of hearing aids in hours, the quality of life related to hearing loss via the APHAB questionnaire. Number of patients: 60 subjects Procedure (number of visits, length of inclusions, duration of follow-up, study schedule patient visits content, brief description of intervention): After the investigator has verified the criteria of inclusion / non inclusion and the subject has signed the written informed consent, the subject will be followed for a period ranging from 2 months to 5 months, during which he attended four visits in a audiology laboratory referenced in this project. During these visits, a fitting of hearing aids face to face or remotely will be realized, and it will be asked to answer a questionnaire to assess quality of life between the two fitting techniques. Study Schedule: Inclusion period: 3 months (M3-M6) Duration of the study for one subject: 2 months to 5 months (M6 to M8 or M6 to M11) Duration statistical analysis / recovery: 3 months (M11-M14) Global Study duration: 14 months 4. Outlook At the end, this project wants to show that a remote fitting provides comparable results to-face fitting in terms of speech perception, in order to be able to offer this type of strategy.

Interventions

DEVICEFace to face fitting

face to face fitting of hearing aids

remote fitting of hearing aids

Sponsors

AudioPro Connect
CollaboratorINDUSTRY
Alliance Audition Montpellier
CollaboratorOTHER
Audition Conseil Perpignan
CollaboratorOTHER
Audition Conseil à Nîmes
CollaboratorOTHER
University Hospital, Montpellier
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
HEALTH_SERVICES_RESEARCH
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to 84 Years
Healthy volunteers
No

Inclusion criteria

* Age limits ≥ 18 et \< 85 years * User of two hearing aids for more than a year * Carriers of adjustable digital hearing aids by means of a software of the usable manufacturer on Windows® PC (in stand-alone or as plug-in in the software NOAH®) to be integrated into the platform AudioProConnect. It is the case of almost all the current hearing aids (Phonak, Starkey, Siemens, Unitron, etc.) * Subject able to understand the nature, the aim and the methodology of the study. * Affiliation or recipient with the mode of social security. * Collection of the informed consent

Exclusion criteria

* Fluctuations in the tonal audiometry, defined as variations furthermore of 10 dB of the average hearing loss (Average arithmetic of thresholds in 500, 1000, 2000 et 4000 Hz) Between the last 2 tonal audiometries realized over the previous 2 years * Cognitive disorders or severe phasic hampering the understanding of the language or the repetition of the speech (Subject not being capable of participating in a vocal audiometry during the last regulation of its hearing aids) * Incapacitated to move in a laboratory of audioprosthesis * Fickle bearing of the hearing aid (\<6h /day ou \< 5day/7) * Tip not adapted little finger * Presence of plugs of earwax at the time of the tests * Patient minor(miner) or protected adults or in the incapacity to give its consent according to the article L1121-8 Of the Public Code of the Health (CSP) * Pregnant or breast-feeding women according to the article L1121-5 du CSP. * Vulnerable people according to the article L1121-6 du CSP.

Design outcomes

Primary

MeasureTime frameDescription
speech perception5 monthsscore PBK test

Secondary

MeasureTime frameDescription
speech in noise audiometry5 months
quality of life5 monthsAPHAB questionnaire
duration of fitting5 months
daily use of hearing aids5 months

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 20, 2026