Skip to content

577nm Micropulse Laser vs Half-dose Photodynamic Therapy on Acute Central Serous Chorioretinopathy

Prospective Randomized Controlled Clinical Trial to Evaluate the Effects of 577nm Micropulse Laser vs Half-dose Photodynamic Therapy on Acute Central Serous Chorioretinopathy

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02587767
Enrollment
68
Registered
2015-10-27
Start date
2016-09-30
Completion date
2019-12-31
Last updated
2022-04-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acute Central Serous Chorioretinopathy

Brief summary

The purpose of this study is to determine whether micropulse laser (MPL) is different to half-dose photodynamic therapy on acute central serous chorioretinopathy.

Detailed description

Central serous chorioretinopathy(CSC) is characterized by serous detachment of neurosensory retina which can cause lose in visual acuity.Some studies have shown that Half-dose photodynamic therapy(PDT) is effective on CSC,although accompanied with side-effects,such as choroidal ischemia, retinal pigmental epithelium(RPE) atrophy,and RPE rip,and with exorbitant price.Recent retrospective studies suggest micropulse laser (MPL) therapy may also be effective without obvious complications in this disease. But to date, there is no study on effectiveness of CSC between PDT and MPL. The study is the first prospective randomized controlled trial about 577nm micropulse laser versus half-dose photodynamic therapy on acute central serous chorioretinopathy.The null hypothesis of the study is that there is difference between MPL and half-dose photodynamic therapy on acute central serous chorioretinopathy at first month after treatment.The primary outcome measures is the proportion of eyes with complete absorption of subretinal fluid at 1 month after treatment.

Interventions

DEVICE577-MPL

All treatments were provided by a single practitioner with the 577-nm yellow laser system(Supra 577nm LaserSystem) in 577-MPL arm. The individual power for the patient was titrated at a normal area of near the affected area in micropulse model.The power titration was started at 700 milliwatt(mW) and then gradually increased until a just visible burn was seen. When this threshold was reached, the power was reduced by 50%, using a 100-μm spot diameter and a 200-ms duration with 5 % duty cycle.

DEVICEHD-PDT

5 minutes after the start of the half-dose verteporfin infusion, the PDT treatment will been performed in HD-PDT arm. The treatment is performed with standard fluency (50 J/cm2), a PDT laser wavelength of 689 nm, and a standard treatment duration of 83 seconds.

Sponsors

Sun Yat-sen University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
TRIPLE (Subject, Caregiver, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 55 Years
Healthy volunteers
No

Inclusion criteria

1. onset for the first time, as an episode duration of less than 6 months 2. patient was between 18 and 55 years of age 3. the presence of subretinal fluid(SRF) involving the macula and detected by use of optical coherence tomography (OCT) 4. active fluorescein leakage during fluorescein angiography (FA) 5. best corrected visual acuity (BCVA) more than 0.1, and less than 1.0

Exclusion criteria

1. previous PDT, focal photocoagulation, intravitreal injections of anti-vascular endothelial growth factor, or ocular surgery 2. other macular abnormalities such as choroidal neovascularization(CNV) or polypoidal choroidal vasculopathy(PCV) 3. retinal atrophy 4. pregnancy 5. inability to obtain photographs or to perform FA 6. use of steroid systemically or topically in the last 6 months

Design outcomes

Primary

MeasureTime frameDescription
the proportion of eyes with complete absorption of subretinal fluid(SRF)1 monthThe primary outcome measure is the OCT-based improvement rate (defined as the proportion of eyes with complete absorption of subretinal fluid on OCT images

Secondary

MeasureTime frameDescription
Change of Best Corrected Visual Acuity(BCVA)1 month, 3 month, 6 month
Change of fundus autofluorescence1 month, 3 month, 6 monthFundus autofluorescence will be evaluated for different patterns(normal, increased, and decreased)before and after treatment
Change in 10°retinal sensitivity1 month, 3 month, 6 monthRetinal sensitivity will be measured by microperimetry
the proportion of eyes with complete absorption of subretinal fluid(SRF)6 monthThe outcome measure is the OCT-based improvement rate (defined as the proportion of eyes with complete absorption of subretinal fluid on OCT images

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026