Skip to content

Diagnostic Accuracy of Point of Care Test of First Voided Urine Compared to Midstream Voided Urine in Primary Care

Is a First Void Urine Sample as Accurate as a Midstream Urine Sample in Diagnosing Urinary Tract Infections With a Point-Of-Care-Test Method in Adult, Symptomatic, Non-pregnant Women in General Practice?

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02585115
Enrollment
117
Registered
2015-10-23
Start date
2015-10-31
Completion date
2016-07-31
Last updated
2016-10-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Urinary Tract Infections

Brief summary

The aim of this study is to determine if sampling technique of urine affects diagnostic modalities in primary care. Furthermore it aims to determine if there is difference in the accuracy of the point-of-care test, when the urine sample is stored at room-temperature and analyzed later in the day.

Detailed description

125 patients with one or more symptoms of urinary tract infections, contacting their GP, are asked to make 2 urine samples from the same void. The patient is asked to void firstly in one cup, approximately 10-20 ml., then stop voiding. Then the patient is asked to void the rest into a second cup. This way there is collected both a first-void and a midstream-void from the same patient and the same void. All the samples are analyzes using urine-dipstick, microscopy and point of care test urine culture. The urine of the midstream void is sent to a Microbiology lab for analyzes as well. Furthermore the test are analyzes again after 1 and 4 hours.

Interventions

None listed

Sponsors

University of Copenhagen
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Symptoms of urinary tract infection

Exclusion criteria

* Men * Pregnancy * Children * Unable to understand the verbal and written guide

Design outcomes

Primary

MeasureTime frame
Difference in accuracy of POC urine culture on first-void urine compared to mid-stream urine wtih mid-stream urine microbiological culture as a reference1 year
Difference in accuracy from 0 hours to 4 hours of the POCT Flexicult ID in the most precise of the above techniques.1 year

Secondary

MeasureTime frame
Proportion of false-positive cultures after 1 hours at room temperature with first-void urine compared to mid-stream urine when using a urin-dipstick1 year
Proportion of false-positive cultures after 1 hours at room temperature with first-void urine compared to mid-stream urine when using microscopy1 year
Proportion of false-positive cultures after 0 hours at room temperature with first-void urine compared to mid-stream urine when using a urin-dipstick1 year
Proportion of false-positive cultures after 4 hours at room temperature with first-void urine compared to mid-stream urine when using microscopy1 year
Proportion of false-positive cultures after 4 hours at room temperature with first-void urine compared to mid-stream urine when using a urin-dipstick1 year
Proportion of false-positive cultures after 0 hours at room temperature with first-void urine compared to mid-stream urine when using microscopy1 year

Countries

Denmark

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026