Idiopathic Macula Hole
Conditions
Brief summary
The purpose of this study is to observe the technologic application of no-touch fluid-air exchange in Surgery of Idiopathic Macula Hole.
Interventions
PROCEDUREno-touch fluid-air exchange
PROCEDUREvitrectomy metrectomy and internal membrane peeling and gas tamponed
Sponsors
Tianjin Medical University Eye Hospital
Study design
Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)
Eligibility
Sex/Gender
ALL
Age
50 Years to 75 Years
Healthy volunteers
No
Inclusion criteria
* All patients were diagnosed as having an idiopathic macular hole(IMH) by Optical Coherence Tomography(OCT).
Exclusion criteria
* Myopia of \>6 diopters * Ocular trauma and other systematic or ocular issues associated with IMHs,such as the other macula disease, for example the degeneration of macula.
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| the closure rate of Macular hole | one month | the closure rate of macular hole through OCT |
Countries
China
Outcome results
None listed