Acute and Cronic Evaluation of AV/PV and VV Delay IEGM Based Optimisation Algorithm-QuickSept Study

Acute and Cronic Evaluation of AV/PV and VV Delay IEGM Based Optimisation Algorithm (QuickOpt™) Compared With Echocardiographic Method for Cardiac Resincronization Therapy in CRT Implants With Right Interventricular Basal-Mid Septum Placement of Leads (QuickSept Study)

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02571868
Acronym
QuickSept
Enrollment
53
Registered
2015-10-08
Start date
2011-01-31
Completion date
2012-01-31
Last updated
2015-10-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure

Brief summary

AtrioVentricular (AV) and InterVentricular (VV) delay optimization can improve ventricular function in Cardiac Resynchronization Therapy (CRT) and is usually performed by means of echocardiography. St Jude Medical has developed an automated algorhythm which calculates the optimal AV and VV delays (QuickOptTM) based on Intracardiac ElectroGrams, (IEGM), within 2 minutes. So far, the efficacy of the algorhythm has been tested acutely with standard lead position at right ventricular (RV) apex. Aim of this project is to evaluate the algorhythm performance in the mid- and long-term with RV lead located in mid-septum.

Detailed description

Primary end-point was to evaluate the relationship between the series of aortic flow Velocity Time Integral (aVTI) values calculated by the two methods at the PV, AV, and VV interval settings recommended by both the QuickOptTM and the standard ECHO optimization in CRT-D patients, at three index times: pre-discharge, at 6-month and at 12-month follow-ups. Secondary end-point was to define the correlation between the optimal AV, PV and VV intervals defined by ECHO, using aVTI measurements and by the QuickOptTM algorithm, IEGM-based.

Interventions

DEVICEOptimization CRT-D

Sponsors

Maria Vittoria Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients with CRT-D * stable and safe placement of an active-fixation RV lead on mid-interventricular septum; * achievement of an efficacious LV intravenous pacing from a Coronary Sinus (CS) branch.

Exclusion criteria

* AF * Patients without spontaneous rhythm

Design outcomes

Primary

MeasureTime frameDescription
Correlation between QuickOptTM and standard ECHO optimization12-monthThe primary endpoint was assessed by means the linear correlation analysis by the Pearson product-moment correlation coefficient to assess the agreement between the ECHO-based and the IEGM-based aVTIs for each of the AV/PV, and VV delay determinations