Skip to content

Transfusion and Coagulation Management in Trauma Patients After the Introduction of a Coagulation Algorithm

Transfusion and Coagulation Management in Trauma Patients After the Introduction of a Coagulation Algorithm

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02569606
Enrollment
1800
Registered
2015-10-07
Start date
2015-09-30
Completion date
2017-12-31
Last updated
2018-05-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hemorrhage

Keywords

consumption of blood, consumption of coagulation products, coagulation algorithm, trauma related transfusion

Brief summary

Comparison of the consumption of blood and coagulation products (packed red blood cells, fresh frozen plasma, platelet concentrates, fibrinogen, coagulation factor concentrates, coagulation factor XIII, activated factor VII, van Willebrand factor and antifibrinolytics) before and after the introduction of a designated trauma related transfusion and coagulation algorithm.The periods 2005-2007 (before) and 2012-2014 (after) the introduction are reviewed. Two level-1 trauma centers in Switzerland (Hospital Lucerne, University Hospital Zurich) are included in the study. Predicted probability of a massive transfusion by the trauma associated acute hemorrhage score (TASH)is correlated with the actual rate.

Detailed description

Trauma is one of the leading causes of death worldwide. After death due to direct craniofacial injury, exsanguination is the next major cause for trauma mortality. After initial pre-hospital treatment the patient is admitted to the hospital. If multiple injuries are present the patient is transferred to a specialized trauma center. Besides surgical treatment, the patient needs stabilization of the vital functions by the Anesthesiologist. Due to loss of blood volume, dilution of the circulatory blood volume and pathological activation of coagulation/fibrinolysis, trauma induced coagulopathy (TIC) is initiated. This needs to be treated and avoided whenever possible. Transfusion of allogeneic blood and coagulation product itself leads to an increased morbidity and mortality. Infectious and immunologic reactions account for that phenomenon. This led to a paradigm change in the therapy of TIC. In 2009 a new coagulation factor based coagulation algorithm was introduced in the Hospital Lucerne and the University Hospital in Zurich / Switzerland. With the help of point of care coagulation measurement, tailored coagulation factor based coagulation management and avoidance of allogeneic blood products was initiated. The investigators now want to analyze the impact of the coagulation algorithm by comparing the periods before and after the introduction of the algorithm. The consumption of blood and coagulation products (packed red blood cells, fresh frozen plasma, platelet concentrates, fibrinogen, coagulation factor concentrates, coagulation factor XIII, activated factor VII, van Willebrand factor and antifibrinolytics) before and after the introduction of a designated trauma related transfusion and coagulation algorithm will be recorded and compared. The periods 2005-2007 (before) and 2012-2014 (after) the introduction are reviewed. Predicted probability of a massive transfusion by the TASH score (trauma associated acute hemorrhage) is correlated with the actual rate.

Interventions

None listed

Sponsors

Luzerner Kantonsspital
CollaboratorOTHER
Donat R. Spahn
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
16 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* male and female trauma patients * admitted to the University hospital of Zurich or the Hospital of Lucerne, Switzerland * injury severity score \>= 16 * time period 2005-2007 and 2012-2014

Exclusion criteria

* incomplete data * denial of informed consent

Design outcomes

Primary

MeasureTime frameDescription
Comparison the consumption of red blood cells, fresh frozen plasma and platelets in the treatment period by the Anaesthesist and after 24/48 hours before (2005-2007) and after (2012-2014) launching the coagulation algorithm.up to 48 hoursThe coagulation algorithm was launched in 2010. To show the difference in transfusion and administration of coagulation products prior and after the changes of coagulation algorithm the probability of massive transfusion (TASH Score) will be compared with the actual rate. The TASH Score is the most precise predictive probability of a massive transfusion. Data of approximately 1800 participants will be compared.
Comparison of the rate of massive transfusion in reality with the predicted rate (by TASH) score.up to 48 hoursMassive transfusion (\>10 units of blood) can be predicted on the base of patient and trauma epidemiology. The investigator compares the actual rate in the institution with the rate predicted by the score.

Secondary

MeasureTime frameDescription
Comparison of the predicted mortality (TRISS/RISC2) with the actual rateup to 30 daysTRISS is a common Score and is a comparative value for trauma mortality outcome. The investigators want to show the benefit of launched coagulation algorithm in mortality after severe trauma.

Countries

Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026