Degenerative Disc Disease, Spinal Stenosis, Spondylolisthesis, Spondylosis
Conditions
Keywords
Robotic Spinal Fusion Surgery
Brief summary
The main objectives of the study are to evaluate the acceptance into operating flow, performance and safety of the AQrate Robotic Assisted System during the spinal fusion surgery
Detailed description
Based on the literature review of similar devices and on the pre-clinical tests performed with the AQrate System on bench and cadavers, the study is build around the following hypothesis: 1. The design and principle of operation of the AQrate System permits a correct integration in the surgical procedure flow thus enabling the surgeon to benefit from its advantages while not generating any additional operational difficulties 2. The stability and ease of use of the device will permit the surgeon to achieve any planned spinal fusion without requiring additional assistance from the medical staff compared to a conventional spinal fusion surgery. 3. A spinal fusion surgery procedure that is performed with the use of the AQrate System is similar to conventional spinal fusion surgery. If correctly used, no additional adverse event should be observed. 4. The exposure to x-ray should decrease as the need of intraoperative recheck of pedicle screws placed should be reduced 5. The precision of placement of pedicle screw should not be adversely affected by the use of the system compared to conventional spinal surgery.
Interventions
Robotic guidance during spinal fusion surgery
Sponsors
Study design
Eligibility
Inclusion criteria
* Adult patients (age from 18 years to 85 years) scheduled for spinal fusion surgery, * Primary spinal surgery (It is the first surgery on this patient's spine) * Patient is capable of complying with study requirements, and * Patient is willing to provide a signed informed consent.
Exclusion criteria
* Pregnancy and lactation * Simultaneous participation in other clinical studies * Infection or malignancy * Previous spondylodesis * Previous spinal surgical procedures * Neurologic diseases (e.g. Charcot-Marie Tooth, Guillain-Barre syndrome, cerebral palsy, neurofibroma) * Spinal cord abnormalities with any neurologic symptoms or signs * Paraplegia * Any other significant disease or disorder which, in the opinion of the Investigator, may either put the participants at risk because of participation in the study, or may influence the result of the study. * Patient cannot follow study protocol, for any reason * Patient cannot or will not sign informed consent * Patients in emergency situation, are not legally competent, cannot understand the situation, * Pediatric patients
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| clinical acceptance of the performance of the AQrate Robotic Assistance System. | Day of surgery | The acceptance of the performance of the AQrate System will be measured by scale given to total of 8 questions. |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Intraoperative exposure to radiation | Day of surgery | Exposure of radiation in seconds from O-arm or other imaging system used during surgery |
| Accuracy of spinal screws placed | Within one month of surgery | The assessment of the accuracy of pedicle screw will be evaluated post operatively on the CT scan, at discharge with the Gertzbein grading scale and copared to a freehand technique |
Countries
Switzerland