Vertebral Body Fracture
Conditions
Keywords
cement leakage, cement augmentation, vertebral body fracture, vertebral cavity, vertebroplasty
Brief summary
Leakage of polymethylmethacrylate (PMMA) is the most common complication during vertebral body augmentation and can lead to serious patient morbidity. Any measure to reduce the rate of cement leakage is of value and makes the procedure safer.The aim of this study was to investigate the effect of the creation of a cavity on cement leakage during vertebroplasty. Investigators tested the hypothesis that the creation of a merely small and irregular cavity in vertebral body prior to cement injection would reduce cement leakage.
Interventions
Fractured Osteoporotic Vertebral Body is Augmented with Injection of Bone Cement
Small Cavity is Created in Fractured Osteoporotic Vertebral Body Prior to Cement Injection
Sponsors
Study design
Eligibility
Inclusion criteria
* Osteoporotic vertebral body fractures of the thoracolumbar spine (T9 to L4) that were classified as A1 fractures according to Arbeitsgemeinschaft Osteosynthesis (AO) Classification
Exclusion criteria
* More Than 2 Vertebral Body Fractures * Fractures of Vertebral Body Based on Malignancy * Previous Spinal Operation * Spinal Infection * Spinal Deformity (scoliosis)
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| CT-Scan evaluation | One week | Number of Cement Extravasation in each Vertebral Body |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Visual Analogue Scale | 3 Months | Scores range from 0 (no pain) to 10 (worst possible pain) |