A Feasibility Study to Evaluate the Safety and Short-term Effectiveness of Transcatheter Pulmonary Valve (TPV)

A Feasibility Study to Evaluate the Safety and Short-term Effectiveness of Implantation of Transcatheter Pulmonary Valve (TPV) for the Treatment of Congenital Heart Disease With Pulmonary Valve Disease

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02555319
Enrollment
10
Registered
2015-09-21
Start date
2015-08-26
Completion date
2021-10-25
Last updated
2023-02-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiovascular Abnormalities, Congenital Heart Defects, Pulmonary Valve Insufficiency, Pulmonary Valve Stenosis

Keywords

Pulmonary Valve, Transcatheter Pulmonary Valve, Congenital Heart Disease

Brief summary

The purpose of this study is to evaluate the safety and short-term effectiveness of implantation of Transcatheter Pulmonary Valve (TPV) for the treatment of congenital heart disease with pulmonary valve disease.

Detailed description

Diverse congenital heart diseases involving the pulmonary artery, such as Tetralogy of Fallot (TOF) with or without pulmonary atresia, or transposition of the great arteries with pulmonary stenosis, require implantation of an artificial conduit between the right ventricle and the pulmonary artery(PA). Because these conduits finally degenerate and result in pulmonary regurgitation and/or stenosis and progressive right ventricle (RV) dilation and eventual failure, patients need repetitive surgery for conduit revision. Transcatheter pulmonary valve implantation (TPVI) is a less invasive alternative to surgery in patients with dysfunctional right ventricular outflow tract (RVOT). TPV is a large-diameter (up to 28 mm) self-expandable stent with a relatively low profile from a nitinol wire backbone with valve leaflets made from porcine pericardial tissue. The TPV is indicated for use in patients with previous undergone replacement of bioprosthetic valve or conduit due to either pulmonary valve atresia, stenosis, regurgitation or a combination of them and present with dysfunctional RVOT requiring treatment for severe pulmonary regurgitation and/or RVOT conduit obstruction. Consecutive subject data should be collected at discharge, 1, 3, 6 month, and 1-5 years post TPV implantation.

Interventions

DEVICETranscatheter Pulmonary Valve (TPV)

Transcatheter Pulmonary Valve Replacement

Sponsors

Seoul National University Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
10 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age greater than or equal to 10 years of age * Body weight greater than or equal to 30 kilograms * Pulmonary regurgitation ≥moderate pulmonary regurgitation (PR) (≥3+) or RVOT conduit obstruction with mean gradient \>35mmHg by echocardiography * pulmonary artery annulus or in situ conduit size ≥16 and ≤26mm * Patient willing to provide written informed consent and comply with follow-up requirements

Exclusion criteria

* Pre-existing mechanical heart valve in any position * Obstruction of the central veins (pulmonic bioprosthesis delivery system to the heart) * Coronary artery compression * A known hypersensitivity to Aspirin or Heparin * Immunosuppressive disease * Active infectious disease (e.g. endocarditis, meningitis) * Estimated survival less than 6 months * Female of child-bearing potential who are unable to take adequate contraceptive precautions, are known to be pregnant, or are currently breastfeeding an infant.

Design outcomes

Primary

MeasureTime frameDescription
Procedural success5dayProcedural success is defined as the TPV implant within desired position, RV-PA peak systolic pressure gradient \<35mmHg by catheter, less mild pulmonary regurgitation by angiography, and freedom from explantation of the TPV at 24 hours post-implant.
Hemodynamic functional improvement at 6month6 monthHemodynamic functional improvement is defined as mean RVOT gradient ≤30 mmHg by continuous wave doppler, and a pulmonary regurgitant fraction \<20% by cardiac magnetic resonance (MR).
Procedural / Device related serious adverse events at 6month6 month

Secondary

MeasureTime frameDescription
New York Heart Association (NYHA) functional classification5 year
Stent fracture5 year
Catheter reintervention on TPV5 year
Hemodynamic function5 yearHemodynamic function will be measured including peak RVOT pressure gradient, mean RVOT pressure gradient, RV-PA pressure gradient, RV pressure, cardiac output, cardiac index, RV end-diastolic volume by echocardiography, cardiac MR, or catheterization.
Procedural / Device related serious adverse events5 year
Death (all cause / procedural / device-related)5 year
Other adverse events5 year
Reoperation5 year
Severity of pulmonary regurgitation5year
Pulmonary regurgitant fraction5year

Countries

South Korea

Outcome results

None listed