Skip to content

Uniformity of Oral Contrast Material in the Bowel

Uniformity of Oral Contrast Material in the Bowel

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02542046
Enrollment
900
Registered
2015-09-04
Start date
2015-09-30
Completion date
2018-01-31
Last updated
2019-12-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Known or Suspected Abdominal Disease

Brief summary

Although positive oral contrast agents are used for the majority of abdominopelvic CT scans in the United States, the quality of bowel opacification has not been compared between the three major classes of positive oral contrast material (barium sulfate, ionic iodinated contrast material, and non-ionic iodinate contrast material). This is a retrospective single institution study of clinical records to show whether the uniformity of bowel opacification is different between the three main types of positive CT oral contrast material used in the United States (Barium sulfate, Diatrizoate, and Iohexol). The investigators will retrospectively identify 250 patients each who received oral barium sulfate, diatrizoate, and iohexol for CT scanning of the abdomen and pelvis (total 750 patients) and assess the quality of bowel lumen opacification by the positive oral contrast agents.

Detailed description

Although positive oral contrast agents are used for the majority of abdominopelvic CT scans in the United States, the quality of bowel opacification has not been compared between the three major classes of positive oral contrast material (barium sulfate, ionic iodinated contrast material, and non-ionic iodinate contrast material). The investigators will retrospectively identify 250 patients each who received oral barium sulfate, diatrizoate, and iohexol for CT scanning of the abdomen and pelvis (total 750 patients) and assess the quality of bowel lumen opacification by the positive oral contrast agents. Primary objective: * To show the uniformity of bowel opacification is different between the three main types of CT oral contrast material used in the United States (Barium sulfate, Diatrizoate, and Iohexol). Secondary objectives: * To show whether or not one of the oral contrast agents provides more uniform opacification than the others in the proximal or distal bowel * To assess the relative opacification of the distal small bowel (ileum) by the three contrast agents.

Interventions

DRUGBarium

Administration of barium oral contrast agent prior to CT scan

DRUGDiatrizoate

Administration of diatrizoate oral contrast agent prior to CT scan

DRUGIohexol

Administration of iohexol oral contrast agent prior to CT scan

Sponsors

General Electric
CollaboratorINDUSTRY
University of California, San Francisco
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* CT scans in which oral contrast material was given

Exclusion criteria

* CT scans in which an obvious paucity of oral contrast material is seen, * CT scans of patients who had studies within 1 week prior where enteric contrast may have been given, including fluoroscopic, endoscopic, or interventional studies

Design outcomes

Primary

MeasureTime frameDescription
Number of Participants With Non-uniform Bowel Lumen Opacification at CT Imagingwithin 1 day from administration of oral contrast. The CT scan generally occurs within 3 hours after oral contrast administration, and the CT scan images will be evaluated for the imaging appearance of oral contrast uniformity for this outcome.Nonuniform contrast enhancement of the bowel lumen is a potential diagnostic pitfall at CT imaging since non-uniform enhancement may be distracting to the reader and interfere with accurate diagnosis. Conversely, homogeneously enhancing bowel lumen makes it easier to assess the bowel for potential disease. For each patient's CT scan, the bowel that is seen to be visibly opacified by oral contrast at CT imaging will be assessed as a whole as showing the presence or absence of nonuniform contrast enhancement of the lumen.
Severity of CT Imaging Artifacts Caused by the Oral Contrast Agentwithin 1 day from administration of oral contrast. The CT scan generally occurs within 3 hours after oral contrast administration, and the CT scan images will be evaluated for the imaging appearance of oral contrast uniformity for this outcome.For the segments of bowel visibly opacified by oral contrast, the severity of CT imaging artifacts caused by the oral contrast agent was recorded on the following 3 point scale: 0 = no artifact; 1 = mild artifact without impairment of anatomic delineation; 2 = severe artifact with impairment of anatomic delineation. Lower scores are preferred

Secondary

MeasureTime frameDescription
Extent of Bowel Opacification of Bowel at CT Imagingwithin 1 day from administration of oral contrast. The CT scan generally occurs within 3 hours after oral contrast administration, and the CT scan images will be evaluated for imaging appearance of oral contrast seen in bowel for this outcome.The most distal segment of bowel (stomach, jejunum, ileum, and /or colon) that was opacified by contrast material at the time of CT imaging was recorded

Countries

United States

Participant flow

Participants by arm

ArmCount
Barium
Patients who received barium sulfate oral contrast for abdominopelvic CT Barium: Administration of barium oral contrast agent prior to CT scan
300
Diatrizoate
Patients who received diatrizoate oral contrast for abdominopelvic CT Diatrizoate: Administration of diatrizoate oral contrast agent prior to CT scan
300
Iohexol
Patients who received iohexol oral contrast for abdominopelvic CT Iohexol: Administration of iohexol oral contrast agent prior to CT scan
300
Total900

Baseline characteristics

CharacteristicBariumDiatrizoateIohexolTotal
Age, Continuous57.8 years58.9 years58.9 years58.5 years
Race and Ethnicity Not Collected0 Participants
Sex: Female, Male
Female
198 Participants166 Participants186 Participants550 Participants
Sex: Female, Male
Male
102 Participants134 Participants114 Participants350 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
EG002
affected / at risk
deaths
Total, all-cause mortality
0 / 3000 / 3000 / 300
other
Total, other adverse events
0 / 3000 / 3000 / 300
serious
Total, serious adverse events
0 / 3000 / 3000 / 300

Outcome results

Primary

Number of Participants With Non-uniform Bowel Lumen Opacification at CT Imaging

Nonuniform contrast enhancement of the bowel lumen is a potential diagnostic pitfall at CT imaging since non-uniform enhancement may be distracting to the reader and interfere with accurate diagnosis. Conversely, homogeneously enhancing bowel lumen makes it easier to assess the bowel for potential disease. For each patient's CT scan, the bowel that is seen to be visibly opacified by oral contrast at CT imaging will be assessed as a whole as showing the presence or absence of nonuniform contrast enhancement of the lumen.

Time frame: within 1 day from administration of oral contrast. The CT scan generally occurs within 3 hours after oral contrast administration, and the CT scan images will be evaluated for the imaging appearance of oral contrast uniformity for this outcome.

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
BariumNumber of Participants With Non-uniform Bowel Lumen Opacification at CT Imaging140 Participants
DiatrizoateNumber of Participants With Non-uniform Bowel Lumen Opacification at CT Imaging73 Participants
IohexolNumber of Participants With Non-uniform Bowel Lumen Opacification at CT Imaging68 Participants
Primary

Severity of CT Imaging Artifacts Caused by the Oral Contrast Agent

For the segments of bowel visibly opacified by oral contrast, the severity of CT imaging artifacts caused by the oral contrast agent was recorded on the following 3 point scale: 0 = no artifact; 1 = mild artifact without impairment of anatomic delineation; 2 = severe artifact with impairment of anatomic delineation. Lower scores are preferred

Time frame: within 1 day from administration of oral contrast. The CT scan generally occurs within 3 hours after oral contrast administration, and the CT scan images will be evaluated for the imaging appearance of oral contrast uniformity for this outcome.

ArmMeasureCategoryValue (COUNT_OF_PARTICIPANTS)
BariumSeverity of CT Imaging Artifacts Caused by the Oral Contrast AgentMild artifact4 Participants
BariumSeverity of CT Imaging Artifacts Caused by the Oral Contrast AgentNo artifact296 Participants
BariumSeverity of CT Imaging Artifacts Caused by the Oral Contrast AgentSevere artifact0 Participants
DiatrizoateSeverity of CT Imaging Artifacts Caused by the Oral Contrast AgentMild artifact6 Participants
DiatrizoateSeverity of CT Imaging Artifacts Caused by the Oral Contrast AgentNo artifact294 Participants
DiatrizoateSeverity of CT Imaging Artifacts Caused by the Oral Contrast AgentSevere artifact0 Participants
IohexolSeverity of CT Imaging Artifacts Caused by the Oral Contrast AgentNo artifact296 Participants
IohexolSeverity of CT Imaging Artifacts Caused by the Oral Contrast AgentSevere artifact0 Participants
IohexolSeverity of CT Imaging Artifacts Caused by the Oral Contrast AgentMild artifact4 Participants
Secondary

Extent of Bowel Opacification of Bowel at CT Imaging

The most distal segment of bowel (stomach, jejunum, ileum, and /or colon) that was opacified by contrast material at the time of CT imaging was recorded

Time frame: within 1 day from administration of oral contrast. The CT scan generally occurs within 3 hours after oral contrast administration, and the CT scan images will be evaluated for imaging appearance of oral contrast seen in bowel for this outcome.

ArmMeasureGroupValue (COUNT_OF_PARTICIPANTS)
BariumExtent of Bowel Opacification of Bowel at CT ImagingColon105 Participants
BariumExtent of Bowel Opacification of Bowel at CT ImagingStomach0 Participants
BariumExtent of Bowel Opacification of Bowel at CT ImagingJejunum24 Participants
BariumExtent of Bowel Opacification of Bowel at CT ImagingDuodenum2 Participants
BariumExtent of Bowel Opacification of Bowel at CT ImagingIleum169 Participants
DiatrizoateExtent of Bowel Opacification of Bowel at CT ImagingDuodenum0 Participants
DiatrizoateExtent of Bowel Opacification of Bowel at CT ImagingColon99 Participants
DiatrizoateExtent of Bowel Opacification of Bowel at CT ImagingIleum174 Participants
DiatrizoateExtent of Bowel Opacification of Bowel at CT ImagingStomach0 Participants
DiatrizoateExtent of Bowel Opacification of Bowel at CT ImagingJejunum27 Participants
IohexolExtent of Bowel Opacification of Bowel at CT ImagingColon34 Participants
IohexolExtent of Bowel Opacification of Bowel at CT ImagingStomach0 Participants
IohexolExtent of Bowel Opacification of Bowel at CT ImagingDuodenum0 Participants
IohexolExtent of Bowel Opacification of Bowel at CT ImagingIleum226 Participants
IohexolExtent of Bowel Opacification of Bowel at CT ImagingJejunum40 Participants

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026