Skip to content

Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve

A Prospective, Multi-center,Randomized Controled Trial of Sizing-strategy of Bicuspid Aortic Valve Stenosis With Transcatheter Self-expandable Valve

Status
UNKNOWN
Phases
Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02541877
Acronym
START
Enrollment
159
Registered
2015-09-04
Start date
2015-09-30
Completion date
2023-09-30
Last updated
2015-09-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Valve Stenosis

Brief summary

To observe the clinical outcomes of the different valve sizing strategies treating type-0 Bicuspid Aortic Stenosis (BAS) with self-expandable transcatheter aortic valve implantation (TAVI) valve, compared with those of a standard sizing strategy of normal Tricuspid Aortic Stenosis(TAS).

Detailed description

BACKGROUND: From our current clinical experience, investigators mostly choose the smaller self-expandable transcatheter valve for type-0 BAS than that for TAS, combined with balloon sizing strategy. But no prospective and randomized studies show the rationality and clinical outcomes of different sizing strategies of type-0 BAS with self-expandable transcatheter valve. AIM: To observe the clinical outcomes of the different valve sizing strategies treating type-0 BAS with self-expandable transcatheter aortic valve implantation (TAVI) valve, compared with those of a standard sizing strategy of normal TAS. POPULATION: All patients with severe degenerative aortic valve stenosis referred for aortic valve intervention will be screened for study eligibility. To be included subjects must be 65 years or older, anatomical and technical eligible for both interventions, expected to survive more than 1 year after the intervention, and able to provide written informed consent. Study exclusion criteria include isolated aortic valve regurgitation or other significant valve disease, unstable preoperative condition. DESIGN: The project is a multicenter randomized clinical trial. Patients of type-0 BAS fulfilling all inclusion and no exclusion criteria will be randomized into either Down sizing group or Standard sizing group. Randomization will be 1:1 with 53 subjects in each group. Meanwhile patients of TAS fulfilling all inclusion and no exclusion criteria will be included as a Standard group in this study. Screening and inclusion will commence in September 2015. Inclusion is expected to last 3 years, and subjects will be followed for 5 years.

Interventions

DEVICEDown sizing valve in type-0 BAS

Subjects will undergo percutaneous retrograde trans-peripheral arterial aortic valve implantation with the self-expandable bio-prosthesis. Before implantation a balloon dilatation of the aortic annulus and a simultaneous aortic root angiography will be performed. Down sizing valve implantation will be used in type-0 BAS.

DEVICEStandard sizing valve in type-0 BAS

Subjects will undergo percutaneous retrograde trans-peripheral arterial aortic valve implantation with the self-expandable bio-prosthesis. Before implantation a balloon dilatation of the aortic annulus and a simultaneous aortic root angiography will be performed. Standard sizing valve implantation will be used in type-0 BAS.

DEVICEStandard sizing valve in TAS

Subjects will undergo percutaneous retrograde trans-peripheral arterial aortic valve implantation with the self-expandable bio-prosthesis. Before implantation a balloon dilatation of the aortic annulus and a simultaneous aortic root angiography will be performed. Standard sizing valve implantation will be used in TAS.

Sponsors

Jian'an Wang,MD,PhD
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
65 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patients with symptomatic severe aortic stenosis (echocardiographic criteria: AV effective orifice area (EOA) of \< 1 cm2, mean AV gradient of \> 40 mmHg, or AV peak systolic velocity of \> 4.0 m/s; NYHA-class II or greater, angina pectoris, or syncope) 2. Subject has been informed of the nature of the study, agrees to its provisions and has provided written informed consent. 3. The subject agrees to comply with specified follow-up evaluations and to return to the investigational site where the procedure was performed. 4. Patients are technical and anatomical eligible for interventions

Exclusion criteria

1. A known hypersensitivity or contraindication to any of the following which cannot be adequately pre-medicated: * Aspirin * Heparin (HIT/HITTS) and bivalirudin * Nitinol (titanium or nickel) * Ticlopidine and clopidogrel * Contrast media 2. Subject refuses a blood transfusion. 3. Other medical, social, or psychological conditions that in the opinion of an Investigator precludes the subject from appropriate consent. 4. Native aortic annulus size \< 20 mm or \> 29 mm per the baseline diagnostic imaging. 5. Life expectancy is less than one year

Design outcomes

Primary

MeasureTime frameDescription
Number of participants with Device successAt 24 hours after procedure1. Absence of procedural mortality 2. Correct positioning of a single prosthetic heart valve into the proper anatomical location 3. Intended performance of the prosthetic heart valve (no prosthesis-patient mismatch and mean aortic valve gradient \<20 mmHg or peak velocity \<3 m/s, AND no moderate or severe prosthetic valve regurgitation)
Changes of prosthetic valve functionsFrom 24 hours after procedure to 5 years1. Valve hemodynamics 2. Peri-valvular regurgitation 3. Valve malpositioning 4. Valve morphology

Secondary

MeasureTime frame
Changes of ascending aortic diameterChanges of baseline ascending aortic diameter at 5 years
All-cause mortality and all stroke (disabling and non-disabling)5 years
Quality of Life (SF-12)5 years
Functional status (NYHA-classification)5 years
Number of patients with procedural complicationsWithin first 30 days

Countries

China

Contacts

Primary ContactXianbao Liu, MD
liuxb2009@hotmail.com+86-13857173887
Backup ContactJian-an Wang, MD,PhD
Wang_jian_an@tom.com+86-13805786328

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026