Skip to content

Prosthetic Fit Assessment in Transtibial Amputees Secondary to Trauma

Prosthetic Fit Assessment in Transtibial Amputees Secondary to Trauma (ProFit)

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02540681
Acronym
ProFit
Enrollment
33
Registered
2015-09-04
Start date
2015-01-31
Completion date
2021-01-31
Last updated
2021-03-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Traumatic Amputation of Lower Extremity

Keywords

Transtibial amputation, Prosthetic fit, Prosthetic alignment

Brief summary

The aims of this study address an exploratory endpoint in the Major Extremity Trauma Research Consortium (METRC) Transtibial Amputation Outcomes Study (TAOS; NCT01821976) that is investigating prosthesis fit, alignment and condition of the residual limb. As there are no validated measures of fit and alignment (factors known to impact comfort, function and performance among amputees) the TAOS study includes a provision in the protocol for acquisition of photographs, video and radiographs in order to help develop uniform assessments of the residual limb. The goal of the ProFit study is to validate and refine the prosthetic assessment tool (ProFit) that was developed by an expert panel of certified orthotist prosthetistis (CPOs) in collaboration with orthopaedic trauma investigators, a measurement scientist and a biomedical engineer from the BADER consortium.

Detailed description

Specific Aim 1: To test the reliability of the ProFit. Patients enrolled in the TAOS trial returning for their eighteen month final visit will undergo radiographic, video, and photographic assessment. A blinded prosthetist panel (PP) will view these remotely and complete a 42 item assessment based on x-ray, photo and video. We will examine two aspects of reliability for the ProFit, inter-rater reliability and internal consistency. Specific Aim 2: To examine the validity and responsiveness of the ProFit. This study aims to examine the validity of the ProFit by specifically evaluating factor validity, construct validity and discriminant validity. This will be accomplished by correlating ProFit scores with measures of self-reported pain (Brief Pain Inventory), function (Short Musculoskeletal Functional Assessment), and satisfaction (Orthotics and Prosthetics User's Survey). Moreover, a subset of subjects will undergo quantitative measurement of fit and alignment using a novel prosthesis-mounted socket reaction moment sensor. Responsiveness of the ProFit will be based on repeated measurements at 6 and 18 months. Specific Aim 3: To develop a shorter version of the ProFit. Based on findings from Aim 1 and 2 at the individual item level, we will remove items that: 1) have poor inter-rater agreement; 2) demonstrate weak relationships with clinician and patient report of overall fit; or 3) exhibit strong ceiling or floor effects. Study design: The ProFit study is a prospective validation study of an assessment of prosthetic fit and alignment among patients with a transtibial amputation. Study duration: 3 years Sample size: 120 TAOS patients will provide adequate power to detect important differences in fit and alignment 18 months following amputation. A subset of 60 patients is necessary to detect significant differences in alignment using the Smart Pyramid. Number of study sites: Up to 35 centers including 24 Core METRC sites, 4 MTFs, and 7 METRC satellite sites. Study population: Patients enrolled in the METRC TAOS study. Outcome measure: This ancillary project to the TAOS trial is designed to study the validity reliability and validity of the ProFit, a 42-item tool for assessing prosthetic fit and alignment among patients with a transtibial amputation. Statistical analysis: Inter-rater reliability and internal consistency will be examined to test the reliability of the ProFit. The validity of this assessment will be evaluated using a variety of construct validity tests. Based on findings from the reliability and validity analysis, a shorter version of the ProFit will be developed. The performance of the shorter version will be determined based on correlation with the original assessment. Randomization: Not applicable Safety monitoring: Not applicable

Interventions

None listed

Sponsors

University of California, San Francisco
CollaboratorOTHER
Major Extremity Trauma Research Consortium
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
No

Inclusion criteria

* Must be enrolled in the TAOS study

Exclusion criteria

* Patients weighing \<300 lbs. * Patient requires an LAR * Women who are breastfeeding or pregnant

Design outcomes

Primary

MeasureTime frameDescription
Prosthetic Fit and Alignment18 monthsA panel of CPOs will evaluate prosthetic fit and alignment using a 42 item assessment tool.

Secondary

MeasureTime frame
Reliability of ProFit assessment tool18 months
Validity of ProFit Assessment tool18 months
Responsiveness of ProFit Assessment tool18 months

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026