The Clinical Application of MCCES in Examination of Human Colon

The Clinical Application of Magnetic-controlled Capsule Endoscopy System in Examination of Human Colon

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02536144
Enrollment
80
Registered
2015-08-31
Start date
2015-08-31
Completion date
2015-09-30
Last updated
2015-08-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Abdominal Pain, Diarrhea, Hematochezia

Keywords

colon capsule, magnetic, maneuverability, colonoscopy

Brief summary

This study is to determine the feasibility and safety of magnetic-controlled capsule endoscopy system in examination of human colon under the real time monitoring by colonoscopy in the clinical application.

Detailed description

Colorectal cancer (CRC) is the second leading cause of cancer-related deaths in the Western world. The screening tests include flexible sigmoidoscopy, optical colonoscopy (OC), double-contrast barium enema , or CT colonography . Such screening can reduce CRC incidence and mortality but its effectiveness depends on its quality, ease of use, and patient adherence .Colon capsule endoscopy(CCE) is being actively evaluated as an emerging complementary or alternative procedure for evaluation of the colon. magnetic -controlled capsule endoscopy system is a new ingestible colon capsule robot provided by Chongqing Jinshan Science & Technology. While Screening the colon, the capsule is drove by magnetic-manipulator outside the body, which means it can move from the cecum to anus step by step under the control of the doctor. However, there's little data report on this colon capsule robot system in clinical application. The investigators plan to conduct this prospective study to determine the feasibility and safety of magnetic-controlled capsule endoscopy system in examination of human colon under the real time monitoring by colonoscopy.

Interventions

PROCEDUREmagnetic-controlled capsule endoscopy system

1. A magnetic-controlled capsule endoscopy(MCCE) included camera,magnet,batter and high polymer material shell. 2. The MCCE would be turned to sleeping mode capturing picture at a rate of 0.5 frame per second after being swallowed. 3. While reaching cecum, the MCCE would be turned to a working mode capturing picture at a rate of 2 frame per second. 4. The MCCE would be controlled by the Magnetic-manipulator out of body to finish the motion of e rotation, somersault, Bird's-eye view, worm's eye view from cecum to anus.

PROCEDUREColonoscopy

1. Bowel preparation should be well done before the examination. 2. A tube with illumination and camera system would insert into colon from anus. 3. From the pictures captured by the camera ,the doctor would see the mucous of the colon.

Sponsors

Nanfang Hospital, Southern Medical University
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
Yes

Inclusion criteria

* Patients who repeatedly have the symptom such as abdominal pain, diarrhea, hematochezia and so on, or * Patients who volunteer to the colonoscopy screening.

Exclusion criteria

* Dysphagia or swallowing disorder, * Congestive heart failure, * Renal insufficiency, * Prior major abdominal surgery of the gastrointestinal tract, * Known or suspected bowel obstruction, * Presence of a cardiac pacemaker or other implanted electromedical devices, * Allergy or contraindication to the medications used in the study.

Design outcomes

Primary

MeasureTime frameDescription
ManeuverabilityFrom the MCCES examination began until the capsule excreted, an expected average of 24hThe Maneuverability was defined as the rotation, somersault, Bird's-eye view, worm's eye view of the capsule, and completing any motion would gain 1 point, eventually ,4 point was good,2-3 point moderate,0-1point poor.

Secondary

MeasureTime frameDescription
Migration length of anus directionFrom the MCCES examination began until the capsule excreted, an expected average of 24hMigration length of anus direction was defined as how long was the distance the capsule controlled by the Magnetic-manipulator moved from cecum to anus in 25 minutes.
The movement of mouth directionFrom the MCCES examination began until the capsule excreted, an expected average of 24hThe movement of mouth direction was defined as if the capsule controlled by the Magnetic-manipulator could move from any point of the colon towards mouth direction.
Nidus of colonDuring the procedureFrom date of the examination until the date of pathological diagnosis, an expected average of 7 days
The level of cleanlinessFrom the MCCES examination began until the capsule excreted, an expected average of 24hThe cleanliness of the colon was graded as excellent (No more than small bits of adherent feces),good(Small amount of feces or dark fluid,but not enough to interfere with the examination ),fair(Enough feces or dark fluid present to preclude a completely reliable examination),poor(large amount of fecal residue).
Procedure related complicationFrom the day of the examination until the follow up ended ,access up to 7 days.Perforation, capsule retention, abdominal pain and so .etc.

Countries

China

Contacts

Primary ContactHongxiang Gu, doctor
Redkind@126.com+86 15975625636
Backup ContactHuiling Zheng, master
bywxling@163.com+86 15013113215

Outcome results

None listed