Mobile Monitoring of Fracture Healing

Mobile Monitoring of Fracture Healing

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02534259
Enrollment
6
Registered
2015-08-27
Start date
2015-08-31
Completion date
2018-03-14
Last updated
2019-02-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Tibial Fractures

Brief summary

The objective of this study is to develop methods for using forces measured on circular external fixators to predict the state of individual patient's healing of severe tibial fractures and defects.

Detailed description

Patients receiving external fixators for tibial fractures and defects will be recruited. Normal struts on the device will be substituted with similar but instrumented struts which enable force measurement. During clinical visits, forces in the fixator, plus foot forces, will be measured during ambulation. Changes in force measurements across treatment and bone healing will be analyzed. Severe fractures in the lower limb are associated with high energy trauma in both civilian and military patients,and are sometimes treated with external fixation devices to stabilize the bone until healing has occurred. The devices are kept on the patient for up to a year or more at significant cost, intrusiveness, and risk of infection. The clinician must decide when to remove the device such that adequate healing has occurred and the bone will not re-fracture, but healing rates are variable and x-rays can be misleading. The clinician must also identify when a patient is starting to progress poorly and an early revision surgery is needed to prevent further complications. The investigators' goal is to develop novel approaches for instrumenting and collecting mechanical data from orthopaedic braces and devices, and identifying new methodologies for interpreting this large volume of functional data for optimizing personalized treatment. The present study is focused on external fixators. Strain gauges will be adhered to the fixators so that fixator forces can be measured during clinical visits. In this pilot study the investigators will develop methods to predict healing based on these measured forces.

Interventions

OTHERForce monitoring of external fixator struts

Sponsors

Milton S. Hershey Medical Center
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1. 18 to 80 years of age 2. Patients scheduled to undergo or currently undergoing treatment at Hershey Medical Center for tibia fracture and/or defect using a circular external fixator including Ilizarov and Taylor Spatial Frame types. 3. Ability to perform study procedures including ambulation (with assistance device if needed)

Exclusion criteria

1. External fixator design that cannot be suitably instrumented for force measurements due to space constraints or other issues 2. Axially stable fracture 3. Inability to understand English 4. Inability to provide informed consent 5. Difficulty maintaining follow-up

Design outcomes

Primary

MeasureTime frame
Forces measured in the external fixator during ambulation during clinical visitsApproximately 5 times across treatment, with treatment lasting months to a year or more

Secondary

MeasureTime frameDescription
Forces measured in instrumented insoles during ambulation during clinical visitsApproximately 5 times across treatment, with treatment lasting months to a year or moreSimultaneously measured during outcome 1 measurements

Other

MeasureTime frameDescription
Radiographic and other clinical assessment of bone healing during clinical visitsApproximately 5 times across treatment, with treatment lasting months to a year or moreSimultaneously measured during outcome 1 measurements

Countries

United States

Outcome results

None listed