Skip to content

Endovascular Repair of Descending ThoracoAbdominal Aortic Pathologies Using Physician Modified Endovascular Prosthesis

Proposed Single Center Investigational Device Exemption: Endovascular Repair of Descending ThoracoAbdominal Aortic Pathologies Using Physician Modified Endovascular Prosthesis

Status
Withdrawn
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02524834
Enrollment
0
Registered
2015-08-17
Start date
2015-05-29
Completion date
2025-02-18
Last updated
2025-05-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Disease

Keywords

Thoracoabdominal lesions

Brief summary

This is an early feasibility study that investigates the outcome of selected patients with complex thoracoabdominal aortic lesions who are suitable for endovascular (within the vessel) repair with a physician-modified Medtronic Thoracic Valiant stent graft. The Medtronic Valiant System includes a Valiant Thoracic Stent Graft, a self-expanding, tubular end prosthesis which is modified/customized by the Investigators to fit the patient's anatomy. The device is constructed by making a taper in the larger proximal thoracic device and attaching it to a smaller distal thoracic device. The Viabahn branches for the visceral vessels are sutured to holes made in the tapered section. The modified Valiant stent graft is advanced to the lesion site endoluminally via the iliac/femoral artery. Access for delivery of extensions to the device will be delivered through the left subclavian artery. Upon deployment, the stent graft self-expands at the target location, where it is designed to exclude the lesion by restoring blood flow through the stent graft lumen.

Detailed description

The study will be conducted with non-surgical or very high-risk patients who are considered suitable candidates for endoluminal repair and who are diagnosed with a Type IV complex thoracoabdominal aortic lesion. The total number of enrolled subjects is planned to be 15. It is a prospective evaluation of patients receiving the device to determine the proportion in whom successful implantation is achieved, as indicated by exclusion of the thoracic lesion and graft patency at implant, time of discharge, and 1, 6, and 12 months following implantation, and to determine the proportion of patients who die or experience adverse events during and after the implantation. Furthermore, the percentage of patients in whom technical and clinical success is achieved, will be determined. Patients will be followed for 5 years after the surgery in which the stent graft is implanted.

Interventions

PROCEDUREExclusion of thoracoabdominal lesion

Endovascular repair of thoracoabdominal lesion with a physician modified Medtronic Valiant stent graft

DEVICEEndovascular Device Implant

Endovascular repair of thoracoabdominal lesion with a physician modified Medtronic Valiant stent graft

Sponsors

Long Beach Memorial Medical Center
CollaboratorOTHER
Rodney A. White, MD
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to 90 Years
Healthy volunteers
No

Inclusion criteria

* Patients must have a Type IV complex thoracoabdominal aortic lesion and be considered candidates for endovascular repair; * Patients must have an ileofemoral access compatible with delivery of a 25 Fr MedtronicValiant thoracic endograft; * Patients must have a left subclavian artery anatomy compatible with 8 mm Dacron conduit to provide safe, sequential antegrade deployments of branch extensions * Patients must have a nonaneurysmal proximal aortic segment distal to the left subclavian artery with at least 2 cm length to assure secure proximal fixation with a * Minimum diameter of 28 mm * Maximum diameter of 42mm * Angle less than 60° relative to axis of the aneurysm * Angle less than 60° relative to axis of the thoracic aorta; * Patients must have a distal fixation iliac artery diameter greater than 2 cm in length and 12-28 mm in diameter; * Patients must be high-risk surgical candidates according to the following established criteria: ASA score of IV.

Exclusion criteria

* Pregnant or pediatric patients (younger than 21 years of age); * Patients who have a condition that threatens to infect the stent graft/aortic valve prosthesis; * Patients with allergies to the stent graft material; * Patients who fail to sign informed consent; * Patients with expected survival less than one year.

Design outcomes

Primary

MeasureTime frameDescription
All cause mortality30 days post interventionEarly (at 30-days) death
Additional endovascular procedureAt 30 daysRe-intervention
Conversion to open repairAt 30 daysSurgical conversion
StrokeAt 30 daysStroke

Secondary

MeasureTime frameDescription
Technical observationsUp to 5 years post interventionIncludes loss of patency, endoleaks, twisting, kinking, fracture of stent graft, migration and separation of components
Composite of myocardial infarction, organ failure, sepsisUp tp 5 years post interventionIncludes Myocardial Infarction, organ failure and sepsis
Vessel complicationsUp to 5 years post interventionIncludes dissection, thrombosis, embolization of vessels, malperfusion of branch vessels

Countries

United States

Outcome results

None listed