Skip to content

Auto Bilevel Adherence Following a Poor Initial Encounter With Continuous Positive Airway Pressure (CPAP)

Phase IV Study of Bi-Level Positive Positive Airway Pressure (BiPAP)Compared to Nasal Continuous Positive Airway Pressure (CPAP) Therapy

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02522442
Acronym
BiPAPRescue
Enrollment
51
Registered
2015-08-13
Start date
2007-08-31
Completion date
2009-01-31
Last updated
2019-04-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Obstructive Sleep Apnea

Brief summary

The primary objective outcome is the proportion of participants compliant (at least four hours of use per night for all nights) in the Auto Bilevel group compared to the continuous positive airway pressure (CPAP) group after 90 days of treatment during the investigation. Proportion will be calculated using the cumulative number of hours on therapy divided by the total number of days of the investigation for each participant. The mean and standard deviation of these mean therapy hours will then be calculated for each arm of the investigation. Participants with compliance of at least four hours will be classified as compliant and those with less than four hours will be classified as non-compliant. The null hypothesis will be rejected if the mean of the primary objective outcome for all participants in the BiPAP® Auto with Bi-Flex® therapy (auto Bilevel) arm is significantly greater than that for all participants in the CPAP therapy arm

Detailed description

Initial Screening It is preferred that participant's are recruited the morning after their failed clinical CPAP titration in the lab. Participants are able to be enrolled within ninety days following this failure if circumstances preclude approach and consent the morning after titration failure. Participants will be asked to wear the Actiwatch for approximately seven days prior to the clinical titration polysomnogram (PSG; and again for seven days prior to their final visit .) Actiwatch is worn on the participant's wrist to assess sleep continuity. Participants will be asked to press the Marker button on the Actiwatch when they get in bed each night to have a documented time mark when the device is downloaded. Participants will also be asked to fill in the sleep diary (provided by sleep clinic) during the seven days (14 days total; 7 at the beginning of the study and 7 days prior to the 90 Day visit) they use the Actiwatch. Randomization/Therapy Initiated (Visit #1) Participants will be randomized and scheduled for a BiPAP® Auto with Bi-Flex® titration or CPAP titration night in the lab. General therapy titration guidelines are documented in Appendix I & II (see Appendix I & II at end of document). Heart Rate Variability (HRV) will be assessed at both the diagnostic portion and titration portion of the research PSG. During the diagnostic portion of the research PSG, HRV needs to be assessed for ten minutes while the participant is awake. At the end of the titration portion of the research PSG, the HRV needs to be assessed for ten consecutive minutes while the participant is awake. Enrolled participants will then complete a questionnaire to assess functional outcomes of sleep quality (FOSQ), Epworth Sleepiness Scale (ESS), Visual Analog Scale (VAS) for mask comfort and satisfaction with therapy, Psychomotor Vigilance Task (PVT), attitudes toward use measurement, and Fatigue Severity Scale (FSS; see Appendix III for description of measurements). Participants will be set up with their respective machines after titration or within ten days (10 +/- 2) days of titration and will take these devices home for the next three months. Thus, total participation in the trial will be on average 3-4 months. All positive airway pressure machines will include a programmed SmartCard to monitor objectively compliance. Participants randomized to standard CPAP therapy will receive a SmartCard programmed to provide CPAP at their prescribed pressure. Both the participant and the sleep health staff administering the questionnaires and psychomotor vigilance task, will be blinded to the therapy the SmartCard is programmed to provide. Participants randomized to novel therapy will receive a SmartCard programmed to provide BiPAP® Auto with Bi-Flex®. The SmartCard programming will be done by an unblinded study staff member. The settings for the novel therapy will be: * Min Expiratory Positive Airway Pressure (EPAP) = 4 cmH2O for prescribed CPAP ≤ 10 cmH2O (use 6 cmH2O for prescribed CPAP \> 10 cmH2O) * Max Inspiratory Positive Airway Pressure (IPAP) = 25 cm H2O * Min Pressure Support (PS) = 2 cm H2O (cannot be adjusted) * MaxPS = 8 cm H2O * Bi-Flex setting of 3 The SmartCard is inserted into the device to provide the programmed therapy. Both the participant and CPAP therapist will be blinded to the therapy the SmartCard is programmed to provide. The other supplies necessary to use the therapy at home will also be provided to the participant (i.e. mask, tubing, humidifier, etc.). The CPAP therapist will also provide the training necessary to use the device at home and provide a number to call in case the participant encounters any difficulty using the device at home. Standardized Counseling to Optimize Adherence to Therapy Counseling to optimize adherence to CPAP therapy will consist of: 1. The clinician will discuss complaints regarding CPAP therapy to identify potential contributors to poor adherence to therapy. The standardized counseling to optimize adherence includes the following measures to address patient complaints and concerns: Interface * Assure current mask is properly applied and headgear is properly adjusted. * Persistent mask leaks or mask discomfort, skin trauma, or skin irritation will be addressed first by verifying mask and headgear adjustment and mask sizing. An alternate mask can be used if the problems cannot be addressed by fit or adjustment interventions. * If mouth leaks are the primary concern and a nasal mask is being used, then a nasal/oral mask will be considered or a chin strap will be offered in combination with nasal mask use. Therapy Side Effects * All patients will have initially been placed on a CPAP device with heated humidification. For continued oro-pharyngeal dryness, nasal dryness, nasal congestion, or rhinitis, humidification will be increased. Saline nasal sprays, steroids, or decongestants can be prescribed, if needed. * Dyspnea on CPAP or claustrophobia will be addressed with counseling as needed. * Note: Reducing the prescribed pressure to improve adherence will not be considered at this time. 2. A standardized description of obstructive sleep apnea (OSA) and its risks will be reviewed with the participant, as well as the American Academy of Sleep Medicine Fact Sheet Drowsy Driving (see Appendix III). 3. A standardized description of the evidence regarding the benefits of positive pressure therapy to treat OSA will be reviewed with the participant. Participants will be instructed to use the device as much as possible while they are sleeping and to also make sure they allow an adequate opportunity to sleep each night.

Interventions

DEVICECPAP

Continuous positive airway pressure

DEVICEAuto BiLevel

Auto Bilevel positive airway pressure with Flex

Sponsors

Mayo Clinic
CollaboratorOTHER
Brigham and Women's Hospital
CollaboratorOTHER
Philips Respironics
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
DOUBLE (Subject, Investigator)

Eligibility

Sex/Gender
ALL
Age
21 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

Participants who meet the inclusion/exclusion criterion below and are willing to participate in the protocol when contacted will be enrolled into the study. Participants need to meet all of the following inclusion criterion below: Inclusion Criterion: 1. Age 21-75 2. New Diagnosis of OSA with a baseline respiratory disturbance index (RDI) ≥ 15 events/hr of sleep determined by either full night or split night PSG 3. Able and willing to provide written informed consent 4. Able to follow study procedures 5. Sub-optimal PSG titration with at least 3 hours of attempted PAP titration (defined below): and deemed by their physician as a titration failure Sub-optimal PSG titration: at least one of the following: 1. Poor sleep efficiency during titration period (sleep efficiency ≤ 70%) (participants may be on sleep medications as per standard lab CPAP protocol ) or; 2. Frequent arousals based on three seconds of alpha frequency on EEG (non periodic limb movement (PLM)-related) of 20 or greater per hour during the titration portion of the study or; 3. CPAP titration aborted due to participant's request (due to intolerance), or 4. Persistent sleep disruption despite therapeutic CPAP therapy and in the judgment of the reviewing physician, suggesting a low probability to CPAP adherence

Exclusion criteria

1. Participation in another interventional research study within the last 30 days 2. Major uncontrolled medical or psychiatric condition such as congestive heart failure, neuromuscular disease, renal failure etc. 3. Prior CPAP or Bi-Level PAP use (within last 2 years) 4. Chronic respiratory failure or insufficiency, moderate Chronic Obstructive Pulmonary Disease (COPD) (FEV1 \< 60%), or any known condition of an elevation of arterial carbon dioxide levels while awake 5. Surgery of the upper airway, nose, sinus, or middle ear within the previous 90 days 6. Presence of an untreated, diagnosable, non-OSA related sleep disorder (e.g. restless legs syndrome, insomnia, etc.) 7. Periodic Limb movement arousal index of 10 or greater. 8. Refusal to consider further interventions to standard CPAP to optimize positive pressure therapy (e.g. different mask than what was used in lab) 9. PAP therapy otherwise medically complicated or contraindicated such as those with a difficult to size or adjust interface (mask) resulting in facial pain, skin irritation or trauma, or excessive air leaks 10. Shift workers or people experiencing jet lag 11. Known history of alcohol and or drug abuse 12. Diagnosis of Complex Sleep Apnea, (appears to be classic obstructive or mixed sleep apnea, but exhibits disruptive central apneas and periodic breathing on CPAP) 11, 12 or persistent central apnea during diagnostic PSG. 13. Diagnosis of Attention Deficit Hyperactivity Disorder 14. Chronic Hypnotic use (nightly use for three months or less)

Design outcomes

Primary

MeasureTime frameDescription
Group Compliance of the Auto Bilevel Group Compared to the CPAP Group Measured by Average Nightly Use.90 daysCompliance was compared between the AutoBiLevel Group and the CPAP group by measuring the average use per night over the study period.
Percentage of Group Compliance of the Auto Bilevel Group Compared to the CPAP Group90 daysPercentage of Group Compliance was compared between AutoBiLevel Group and the CPAP group by measuring proportion of adherent users over the treatment period. Patients with compliance of at least four hours will be classified as compliant and those with less than four hours will be classified as non-compliant. The % of compliant patients will be calculated using the cumulative number of hours on therapy divided by the total number of days of the investigation for each subject.

Secondary

MeasureTime frameDescription
Epworth Sleepiness ScaleAssessed at Baseline, Day 30 and Day 90The Epworth Sleepiness Scale is an 8 item questionnaire that measures the general level of daytime sleepiness. Participants were asked what the chance is they would doze off or fall asleep during different routine daytime situations. The survey answers questions on a scale of 0 to 3- 0 being no chance and 3 being a high chance of dozing. The lowest score possible is a 0 and the highest score possible is a 24.
Fatigue Severity ScaleAssessed at Baseline, Day 30 and Day 90The Fatigue Severity Scale is a 9-item scale which measures the severity of fatigue and its effect on a person's activities and lifestyle in patients with a variety of disorders. Participants answer questions on a scale of 1-7, 1 being Strongly Disagree and 7 being Strongly Agree. The scores can range from 9-63. The higher the score the higher the fatigue.
Functional Outcomes of Sleep QualityAssessed at Baseline, Day 30 and Day 90Functional Outcomes of Sleep Quality consists of 30 questions related to the effects of fatigue on daily activities, the instrument was designed to evaluate the respondent's quality of life as it relates to disorders of excessive sleepiness. Five domains of day-to-day life are examined: activity levels, vigilance, intimacy and sexual relationships, productivity, and social outcomes. The participants answer on a scale of 0-4: 0 -I don't do this activity for other reasons,1-Yes, extreme, 2-Yes, moderate, 3-Yes, a little, 4-No. Scores can range 0-120, the lower the score the more tired or sleepy the participant is.

Countries

United States

Participant flow

Recruitment details

A total of 51 patients completing clinical polysomnography (PSG) with CPAP was assessed for study eligibility and consented to study participation across 3 study sites.

Pre-assignment details

3 participants aborted their PSG during titration and were not considered for randomization into this trial. They were not included in the baseline demographic analysis.

Participants by arm

ArmCount
Auto BiLevel Group
Auto Bilevel; auto-titrating bilevel positive airway pressure device with pressure flexing used as experimental treatment for obstructive sleep apnea
26
CPAP Group
CPAP; continuous positive airway pressure used as comparator treatment for obstructive sleep apnea
22
Total48

Baseline characteristics

CharacteristicAuto BiLevel GroupCPAP GroupTotal
Age, Continuous54.1 years
STANDARD_DEVIATION 12.5
56.6 years
STANDARD_DEVIATION 9.8
55.4 years
STANDARD_DEVIATION 11.1
Alcohol Use13 Participants11 Participants24 Participants
ATU-A, Self-Efficacy20.4 units on a scale
STANDARD_DEVIATION 3.2
19 units on a scale
STANDARD_DEVIATION 4.7
19.6 units on a scale
STANDARD_DEVIATION 4
BMI34.9 kilograms per meter squared
STANDARD_DEVIATION 6.5
31 kilograms per meter squared
STANDARD_DEVIATION 4.4
33.0 kilograms per meter squared
STANDARD_DEVIATION 5.9
College Education Level16 Participants12 Participants28 Participants
Nicotine Use5 Participants5 Participants10 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
2 Participants0 Participants2 Participants
Race (NIH/OMB)
Black or African American
0 Participants1 Participants1 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants1 Participants1 Participants
Race (NIH/OMB)
White
24 Participants20 Participants44 Participants
Region of Enrollment
United States
26 participants22 participants48 participants
Sex: Female, Male
Female
6 Participants6 Participants12 Participants
Sex: Female, Male
Male
20 Participants16 Participants36 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
— / —— / —
other
Total, other adverse events
0 / 260 / 22
serious
Total, serious adverse events
0 / 260 / 22

Outcome results

Primary

Group Compliance of the Auto Bilevel Group Compared to the CPAP Group Measured by Average Nightly Use.

Compliance was compared between the AutoBiLevel Group and the CPAP group by measuring the average use per night over the study period.

Time frame: 90 days

Population: One randomized participant discontinued the study early (auto-bilevel Group). One participant in the CPAP group used therapy the first night and failed for the remainder of the study but completed all study visits.

ArmMeasureValue (MEAN)Dispersion
Auto BiLevel GroupGroup Compliance of the Auto Bilevel Group Compared to the CPAP Group Measured by Average Nightly Use.284.7 minutes/nightStandard Deviation 110.9
CPAP GroupGroup Compliance of the Auto Bilevel Group Compared to the CPAP Group Measured by Average Nightly Use.255.1 minutes/nightStandard Deviation 116.9
Comparison: Pilot study, not powered for any endpoint.p-value: 0.377Chi-squared
Primary

Percentage of Group Compliance of the Auto Bilevel Group Compared to the CPAP Group

Percentage of Group Compliance was compared between AutoBiLevel Group and the CPAP group by measuring proportion of adherent users over the treatment period. Patients with compliance of at least four hours will be classified as compliant and those with less than four hours will be classified as non-compliant. The % of compliant patients will be calculated using the cumulative number of hours on therapy divided by the total number of days of the investigation for each subject.

Time frame: 90 days

Population: One randomized participant discontinued the study early (auto-bilevel Group). One participant in the CPAP group used therapy the first night and failed for the remainder of the study but completed all study visits.

ArmMeasureValue (NUMBER)
Auto BiLevel GroupPercentage of Group Compliance of the Auto Bilevel Group Compared to the CPAP Group62 percentage of compliant users
CPAP GroupPercentage of Group Compliance of the Auto Bilevel Group Compared to the CPAP Group55 percentage of compliant users
p-value: 0.624Chi-squared
Secondary

Epworth Sleepiness Scale

The Epworth Sleepiness Scale is an 8 item questionnaire that measures the general level of daytime sleepiness. Participants were asked what the chance is they would doze off or fall asleep during different routine daytime situations. The survey answers questions on a scale of 0 to 3- 0 being no chance and 3 being a high chance of dozing. The lowest score possible is a 0 and the highest score possible is a 24.

Time frame: Assessed at Baseline, Day 30 and Day 90

ArmMeasureGroupValue (MEAN)Dispersion
Auto BiLevel GroupEpworth Sleepiness ScaleDay 308.2 units on a scaleStandard Deviation 3.2
Auto BiLevel GroupEpworth Sleepiness ScaleDay 908.1 units on a scaleStandard Deviation 3.8
Auto BiLevel GroupEpworth Sleepiness ScaleBasline9.7 units on a scaleStandard Deviation 3.9
CPAP GroupEpworth Sleepiness ScaleBasline8.2 units on a scaleStandard Deviation 4.6
CPAP GroupEpworth Sleepiness ScaleDay 306.6 units on a scaleStandard Deviation 4.6
CPAP GroupEpworth Sleepiness ScaleDay 906.9 units on a scaleStandard Deviation 4.4
Secondary

Fatigue Severity Scale

The Fatigue Severity Scale is a 9-item scale which measures the severity of fatigue and its effect on a person's activities and lifestyle in patients with a variety of disorders. Participants answer questions on a scale of 1-7, 1 being Strongly Disagree and 7 being Strongly Agree. The scores can range from 9-63. The higher the score the higher the fatigue.

Time frame: Assessed at Baseline, Day 30 and Day 90

ArmMeasureGroupValue (MEAN)Dispersion
Auto BiLevel GroupFatigue Severity Scale90 day3.9 units on a scaleStandard Deviation 0.9
Auto BiLevel GroupFatigue Severity ScaleBaseline4.6 units on a scaleStandard Deviation 1.4
Auto BiLevel GroupFatigue Severity Scale30 day4.0 units on a scaleStandard Deviation 1.2
CPAP GroupFatigue Severity Scale30 day3.7 units on a scaleStandard Deviation 1.2
CPAP GroupFatigue Severity Scale90 day3.4 units on a scaleStandard Deviation 1.2
CPAP GroupFatigue Severity ScaleBaseline3.9 units on a scaleStandard Deviation 1
Secondary

Functional Outcomes of Sleep Quality

Functional Outcomes of Sleep Quality consists of 30 questions related to the effects of fatigue on daily activities, the instrument was designed to evaluate the respondent's quality of life as it relates to disorders of excessive sleepiness. Five domains of day-to-day life are examined: activity levels, vigilance, intimacy and sexual relationships, productivity, and social outcomes. The participants answer on a scale of 0-4: 0 -I don't do this activity for other reasons,1-Yes, extreme, 2-Yes, moderate, 3-Yes, a little, 4-No. Scores can range 0-120, the lower the score the more tired or sleepy the participant is.

Time frame: Assessed at Baseline, Day 30 and Day 90

ArmMeasureGroupValue (MEAN)Dispersion
Auto BiLevel GroupFunctional Outcomes of Sleep QualityBaseline84.0 units on a scaleStandard Deviation 20.9
Auto BiLevel GroupFunctional Outcomes of Sleep Quality30 day97.5 units on a scaleStandard Deviation 13.8
Auto BiLevel GroupFunctional Outcomes of Sleep Quality90 day100.0 units on a scaleStandard Deviation 11.3
CPAP GroupFunctional Outcomes of Sleep QualityBaseline91.4 units on a scaleStandard Deviation 17.3
CPAP GroupFunctional Outcomes of Sleep Quality30 day96.6 units on a scaleStandard Deviation 16.6
CPAP GroupFunctional Outcomes of Sleep Quality90 day100.1 units on a scaleStandard Deviation 15.4

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026