Skip to content

Stroke and Traumatic Acute Brain Injury Line Indicator System for Emergent Recognition (STABILISER-I)

Stroke and Traumatic Acute Brain Injury Line Indicator System for Emergent Recognition (STABILISER-I)

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02514902
Acronym
STABILISER-I
Enrollment
48
Registered
2015-08-04
Start date
2015-03-25
Completion date
2016-12-16
Last updated
2017-02-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hemorrhagic Stroke, Ischemic Stroke, Traumatic Brain Injury

Keywords

Lateral Flow Device (LFD), Acute Stroke, Traumatic Brain Injury (TBI), Point of Care (POC), Biomarker

Brief summary

In the search for a novel marker of stroke that could be rapidly assessed in blood, the investigators developed a point-of-care (POC) lateral flow device (LFD) that rapidly (\< 15 min) detects levels of a biomarker that is released into blood following neuronal injury associated with stroke and traumatic brain injury. The protein's expression in human brain should serve as a useful biomarker of neuronal injury in stroke and traumatic brain injury.

Detailed description

The use of a lateral flow device (LFD) to indicate the presence of a blood biomarker is feasible and may provide an important diagnostic tool for stroke and traumatic brain injury (TBI). Primary Objectives: 1. Determine the first-in-humans feasibility using the investigators' biomarker lateral flow device on whole blood samples to diagnose patients with acute stroke (both ischemic and hemorrhagic) and traumatic brain injury being evaluated in the Emergency Department and Inpatient Services at University of Kentucky. Provide initial pilot data for estimating sensitivity and specificity of the assay. 2. Establish a visual ordinal grading scale that is easy to use clinically to judge the severity of injury, from the Lateral Flow Device result. Verify that the visual scale has inter-rater reliability, and evaluate it against a digital detection assay. 3. Examine the correlation between clinical and radiographic parameters of injury severity and blood levels of the biomarker. The investigators will correlate the results of the test with NIH Stroke Scale and with MRI infarct volume for ischemic stroke, with hemorrhage volume on CT for hemorrhagic stroke, and with Glasgow Coma Scale for Traumatic Brain Injury (TBI).

Interventions

A drop of whole blood from a finger stick is placed on the lateral flow device at two different time points to indicate the presence of a neuronal specific biomarker. The results will also be correlated to severity of clinical and radiographic injury. Separate drops are evaluated similarly for serum levels. The objective is to determine feasibility of a diagnostic tool for stroke (ischemic and hemorrhagic and traumatic brain injury (TBI). No diagnostic results or resulting treatments will be applied to any subject.

Sponsors

University of Kentucky
CollaboratorOTHER
Justin Fraser
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to 85 Years
Healthy volunteers
Yes

Inclusion criteria

1. Patients 21-85 years old, male or female. 2. Suspected TBI, acute ischemic stroke, or nontraumatic/nonlesional intracerebral hemorrhage (ICH) based on clinical and radiographic evidence as determined and documented by the appropriate service (Trauma Service or Neurosurgery Service for TBI; Neurology or Neurosurgery Service for Stroke) at University of Kentucky. 3. Patients with impaired capacity may be included; as the pathology to be studied (stroke or TBI) may impair their capacity (please see attached required documentation regarding impaired capacity).

Exclusion criteria

1. Pregnant women as the effect of pregnancy on the biomarker testing result is as yet unknown. 2. While patients may be included with the above listed diagnoses, they may be excluded later if an alternate unlisted diagnosis is found to be the root cause of their presentation. An example would be a patient initially thought to have a stroke, who is discovered to be suffering from a seizure instead.

Design outcomes

Primary

MeasureTime frameDescription
Whole Blood Biomarker Results on the Visual Analog ScaleWithin 8 hours of time of injury/onset of stroke symptoms.Degree of response to a protein specific biomarker in whole blood as indicated by the Lateral Flow Device's analog scale: negative / mild / moderate / severe.

Secondary

MeasureTime frameDescription
Whole Blood Biomarker Results on the Visual Analog ScaleWithin 48 ± 8 hours of time of injury/onset of stroke symptoms.Degree of response to a protein specific biomarker in whole blood as indicated by the Lateral Flow Device's analog scale: negative / mild / moderate / severe.
Serum Biomarker Results on the Visual Analog ScaleWithin 8 hours of time of injury/onset of stroke symptoms.Degree of response to a protein specific biomarker in serum as indicated by the Lateral Flow Device's analog scale: negative / mild / moderate / severe.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026