Atrial Fibrillation
Conditions
Brief summary
This study is a prospective, multicenter, randomized (2:1) controlled study to evaluate the safety and effectiveness of the LARIAT System to percutaneously isolate and ligate the Left Atrial Appendage from the left atrium as an adjunct to planned pulmonary vein isolation (PVI) catheter ablation in the treatment of subjects with symptomatic persistent or longstanding persistent atrial fibrillation. This study will be conducted in two stages: * Limited Early Stage (Stage 1): up to 250 subjects at up to 65 sites. (COMPLETED, transitioned to Stage 2) * Pivotal Stage/ Phase III (Stage 2): up to 600 subjects at up to 65 sites. (COMPLETED) All subjects from both stages will be included in the primary analysis.
Interventions
Left Atrial Appendage ligation with the LARIAT System initially performed followed by adjunctive pulmonary vein isolation catheter ablation in staged procedures
Perform pulmonary vein isolation (PVI) catheter ablation procedure using a contact force sensing, irrigated radiofrequency catheter approved by FDA for the treatment of atrial fibrillation.
Sponsors
Study design
Eligibility
Inclusion criteria
* Documented diagnosis of symptomatic continuous persistent or longstanding persistent non-valvular atrial fibrillation * Failed at least one Class I or III Antiarrythmic drug (AAD) and therefore, eligible and intended for standard of care catheter ablation; * Life expectancy ≥ 1 year; * Willing and able to return to and comply with scheduled follow-up visits and tests; and * Willing and able to provide written informed consent
Exclusion criteria
* Prior procedure involving opening of the pericardium or entering the pericardial space (e.g., coronary artery bypass graft, heart transplantation, valve surgery) where adhesions are suspected; * Any prior epicardial ablation or any type of left-sided atrial ablation procedure; * LA diameter \> 6 cm as measured by computerized tomography and confirmed by the imaging core laboratory; * Documented embolic stroke, transient ischemic attach or suspected neurologic event within 3 months prior to the planned study intervention; * Currently exhibits New York Heart Association Class IV heart failure symptoms; * Documented history of right heart failure specifically when right ventricle exceeds the left ventricular size; * Documented history of myocardial infarction (MI) within 3 months prior to the planned study intervention; * Documented history of unstable angina within 3 months prior to the planned study intervention; * Documented history of cardiogenic shock, hemodynamic instability or any medical condition in which intra-aortic balloon pump (IABP) therapy is clinically indicated within 3 months prior to the planned study intervention; * Documented symptomatic carotid disease, defined as \> 70% stenosis or \> 50% stenosis with symptoms; * Diagnosed active local or systemic infection, septicemia or fever of unknown origin at tme of baseline screening; * Chronic renal insufficiency defined as eGFR \< 30 mL/min/1.73m2 within 3 months prior to planned study intervention; * End Stage Renal Disease (ESRD) or documented history of renal replacement / dialysis; * Current documented history of clinically significant liver disease which predisposes the subject to significant bleeding risk (clinically defined by the treating physician); * Any history of thoracic radiation with the exception of localized radiation treatment for breast cancer; * Current documented use of long-term treatment with oral corticoid steroids, not including use of inhaled steroids for respiratory diseases; * Active pericarditis; * Active endocarditis; * Any documented history or autoimmune disease associated with pericarditis; * Evidence of Pectus Excavatum (documented and clinically defined by the treating physician); * Untreated severe scoliosis (documented and clinically defined by treating physician); * Documented Left Ventricular Ejection Fraction (LVEF) \< 30% within 30 days prior to planned intervention; * Documented presence of implanted congenital defect closure devices, (e.g., atrial septal defect, patent foramen ovale or ventricular septal defect device); * Previously attempted occlusion of the left atrial appendage (by any surgical or percutaneous method); * Inability, or unwillingness or contraindication to undergo TEE or CTA imaging or 24-hour Holter monitoring; * Body Mass Index (BMI) \> 40; * Evidence of active Graves disease; * Current untreated hypothyroidism; * Any contraindication to suture, endovascular device, or other minimally invasive techniques including percutaneous, transseptal, and/or sub-xiphoid access; * Subject is pregnant or plans / desires to get pregnant within next 12 months; * Current enrollment in an investigation or study of an investigational device or investigational drug that would interfere with this study and the required follow up; * Mental impairment or other psychiatric conditions which may not allow patient to understand the nature, significance and scope of the study; * Any other criteria, medical illness or comorbidity which would make the subject unsuitable to participate in this study as determined by the clinical site Primary Investigator; Additional
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Freedom from episodes of atrial fibrillation > 30 seconds at 12 months post index pulmonary vein isolation | 12 months following Pulmonary Vein Isolation catheter ablation procedure | Measured by 24-hour Holter Monitoring |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Freedom from any atrial fibrillation/atrial tachycardia/atrial flutter recurrence defined as any episode > 30 seconds with or without AAD | Following the 90 day blanking period through 12 months post-index pulmonary vein isolation | Measured by 24-hour Holter Monitoring |
| Composite endpoint of stroke of any cause and systemic embolism as adjudicated by the clinical events committee | 12 months following index pulmonary vein isolation | — |
Other
| Measure | Time frame | Description |
|---|---|---|
| LARIAT Technical Success | Immediately post-LARIAT ligation (acute) and at 12 months following index pulmonary vein isolation | Successful placement of the LARIAT device pre-tied suture around the left atrial appendage to achieve left atrial appendage ligation defined as ≤1 ± 1mm diameter residual communication w/ left atrium, as assessed by transesophageal echocardiography |
Countries
United States