Skip to content

SD-OCT Angiography

Spectral Domain-Optical Coherence Tomography Angiography of Retinal Diseases

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02510885
Enrollment
39
Registered
2015-07-29
Start date
2015-07-31
Completion date
2019-03-11
Last updated
2022-04-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Age-related Macular Degeneration, Diabetic Macular Edema, Diabetic Retinopathy, Neovascular Age-related Macular Degeneration, Retinal Vein Occlusion

Keywords

neovascular age-related macular degeneration, age-related macular degeneration, diabetic retinopathy, SD-OCT, Angiography, diabetic macular edema

Brief summary

The objective of this study is to image retinal vascular alterations in patients with retinal disease using the AngioVue OCT-A system and understand the information these images provide. The investigators will image study participants who have retinal diseases with the AngioVue unit (Optovue) and will collect relevant clinical data to understand the nature of the information contained in images obtained on AngioVue. This study being conducted under an abbreviated IDE. The investigators will analyze data using descriptive statistics. Risks related to light exposure will be managed by ensuring that the exposure to the AngioVue light source is well below maximum permissible limits for safe exposure.

Detailed description

OCT is an optical ranging and imaging technique first described in 1991 that has since been used successfully to provide high-resolution, micrometer-scale depth imaging in clinical ophthalmology (and other fields). It can be thought of as the optical analogue of ultrasound imaging. For the ocular posterior segment, OCT provides rapid acquisition of high-resolution, cross-sectional images of the retina that approximate tissue histology. In vivo imaging of the retina with OCT has thus dramatically improved clinicians' diagnostic capabilities, allowing earlier and more accurate diagnosis of disease and more precise assessment of response to therapies over time. While OCT provides important information on retinal anatomy, it is currently limited in its ability to provide information on retinal vasculature and blood flow. Angiography is the current gold-standard imaging modality for retinal vascular imaging. Angiography involves intravenous injection of a fluorescent dye (typically either fluorescein or indocyanine green for the retinal or choroidal vessels, respectively) that circulates through the body. A light source emitting light at the specific excitation wavelength of the dye is placed in front of the patient's eye, and a camera equipped with a filter corresponding to the emission wavelength of the dye is then used to image vessel morphology and retinal perfusion, either through still images or through a short movie. Angiography provides physiologic information about the retina that complements the anatomical information provided by OCT. While generally well tolerated by most patients, angiography does have drawbacks: it often requires the use of a separate imaging system, it requires several minutes for image acquisition, and it involves intravenous injection of a dye. Patients occasionally experience side effects of intravenous dye administration, including nausea, discomfort, and rarely, anaphylaxis. Several retinal imaging companies are developing the next generation of OCT technology: OCT angiography (OCT-A). OCT-A allows noninvasive, high-resolution imaging of the microvasculature of the retina and choroid (the vascular plexus subjacent to the retina), without the need for intravenous dye administration. OCT-A platforms currently under development include both spectral domain (SD) and swept-source (SS) based technologies. Whereas SS-based OCT-A utilizes a longer wavelength (\ 1060 nm) light source, SD-based units use the same light source used in commercially available and FDA-cleared OCT units on a modified platform. Optovue, Inc. (Fremont, CA) has developed one such unit, a customized, high-resolution SD-OCT system that implements a novel algorithm, the amplitude-based method of split-spectrum amplitude-decorrelation angiography (SSADA) for OCT-A. This SSADA algorithm allows for detection of motion in the blood vessel lumen by measuring the variation in reflected OCT signal amplitude between consecutive cross-sectional scans. Optovue has integrated the novel SSADA algorithm into their commercially approved RTVue SD-OCT unit for their OCT-A unit, the AngioVue. The AngioVue can generate high-quality angiograms of both the retina and choroid. Additionally, this refined method has produced images of the smallest retinal vessels (capillaries) in normal healthy control participants. In this proposed prospective interactive clinical study, we will use the AngioVue unit to image patients and characterize vascular abnormalities that are present in the setting of retinal diseases.

Interventions

DEVICEAngioVue SD-OCT

OCT-A allows noninvasive, high-resolution imaging of the microvasculature of the retina and choroid, without intravenous dye administration. SD-OCT units use the light source used in commercially available and FDA-cleared OCT units on a modified platform. Optovue, Inc. has developed a customized SD-OCT system that implements a novel algorithm, the amplitude-based method of split-spectrum amplitude-decorrelation angiography (SSADA) for OCT-A. This detects motion in the blood vessel lumen by measuring the variation in reflected OCT signal amplitude between consecutive cross-sectional scans. Optovue has integrated the novel SSADA algorithm into their commercially approved RTVue SD-OCT unit for their OCT-A unit, the AngioVue. This unit is being conducted under an abbreviated IDE.

Sponsors

Optovue
CollaboratorINDUSTRY
Duke University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Capable and willing to provide consent * History of clinically diagnosed retinal diseases, including but not limited to age-related macular degeneration, diabetic retinopathy, retinal vein occlusion, macular telangiectasias, and diabetic macular edema * At least 18 years of age

Exclusion criteria

* Unable or unwilling to give consent * Under 18 years of age

Design outcomes

Primary

MeasureTime frame
Number of Participants With Image Quality Sensitive Enough to Identify Specific New Vessel MorphologyDay 0

Countries

United States

Participant flow

Participants by arm

ArmCount
SD-OCT Angiography
Study participants will undergo imaging of both eyes with the AngioVue unit (approx. 60 seconds/eye), per standard operating protocol. Imaging is noncontact, and pharmacologic dilation will not be used for the purposes of this study. In most instances, study participants will undergo only a single imaging session on a single day. However, potential participants will be asked to consent for additional imaging sessions (up to 12) that may occur over the course of subsequent future visits to the clinic. Additionally, study participants will be asked to consent to prospective collection of clinical and demographic data, to correlate findings of OCT-A imaging to subsequent clinical course. AngioVue SD-OCT: OCT-A allows noninvasive, high-resolution imaging of the microvasculature of the retina and choroid, without intravenous dye administration. SD-OCT units use the light source used in commercially available and FDA-cleared OCT units on a modified platform. Optovue, Inc. has developed a customized SD-OCT system that implements a novel algorithm, the amplitude-based method of split-spectrum amplitude-decorrelation angiography (SSADA) for OCT-A. This detects motion in the blood vessel lumen by measuring the variation in reflected OCT signal amplitude between consecutive cross-sectional scans. Optovue has integrated the novel SSADA algorithm into their commercially approved RTVue SD-OCT unit for their OCT-A unit, the AngioVue. This unit is being conducted under an abbreviated IDE.
39
Total39

Baseline characteristics

CharacteristicSD-OCT Angiography
Age, Continuous64.4 years
STANDARD_DEVIATION 19.5
Ethnicity (NIH/OMB)
Hispanic or Latino
1 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
38 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants
Region of Enrollment
United States
39 Participants
Sex: Female, Male
Female
20 Participants
Sex: Female, Male
Male
19 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 39
other
Total, other adverse events
0 / 39
serious
Total, serious adverse events
0 / 39

Outcome results

Primary

Number of Participants With Image Quality Sensitive Enough to Identify Specific New Vessel Morphology

Time frame: Day 0

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
SD-OCT AngiographyNumber of Participants With Image Quality Sensitive Enough to Identify Specific New Vessel Morphology39 Participants

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026