Skip to content

Study of Platelet Activation by Severe Aortic Stenosis and Its Correction by Transcatheter Aortic Valve Implantation

Study of Platelet Activation by Severe Aortic Stenosis and Its Correction by Transcatheter Aortic Valve Implantation (TAVI) Platelet Activation in TAVI

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02504632
Acronym
TAVI
Enrollment
44
Registered
2015-07-22
Start date
2014-05-31
Completion date
2015-10-31
Last updated
2017-03-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Stenosis

Keywords

platelet activation, transcatheter aortic valve implantation

Brief summary

Study of platelet activation by severe aortic stenosis and its correction by Transcatheter Aortic Valve Implantation (TAVI)

Detailed description

* Background: TAVI has emerged as an alternative to surgical aortic valve replacement for patients with severe, symptomatic aortic stenosis (AS) and is expanding worldwide with more than 50,000 patients treated to date. * Purpose Changes in haemostasis, particularly in platelet activation or reactivity before, during and after TAVI have never been studied. Valve replacement is known to alleviate von Willebrand factor abnormalities associated with AS. A potential improvement of platelet function could also occur after TAVI. Indeed, circulating platelets may be desensitized and under-reactive due to multiple passages through the stenotic valve and could recover normal reactivity after TAVI. Besides, TAVI presents a risk of major ischemic complications. The investigators can hypothesize the involvement of high reactive platelets in peri-procedural thrombotic or ischemic events. This study of the platelet activation kinetics will be performed by comparing several specific markers before and at various times after valve implantation. * Primary outcome To evaluate the kinetics of platelet activation before and at various times after valve implantation, by comparing several specific markers in peripheral venous blood samples before (day 0) and at days 1 and 5±1 after the procedure. * Study design and number of subjects: This is a prospective, monocentric, study. The test group includes up to 15 patients treated by transfemoral TAVI using a MedTronic CoreValve (MCV) prosthesis. Platelet activation will be studied before and after the procedure and compared to a reference established with an age-matched, aspirin-treated, atherosclerotic population (30 patients in the control group). * Eligibility criteria: * inclusion criteria: test group: patients with severe aortic stenosis and transfemoral TAVI with MCV aspirin treatment . Control group: age-matched patients with stable coronary artery disease treated by aspirin but without aortic stenosis. * exclusion criteria: recent (1 month) acute coronary syndrome; treatment by anti platelet agents other than aspirin * Procedures: Specific platelet activation markers, circulating platelet/monocytes aggregates, platelet reactivity and vWF will be assessed in peripheral venous blood before, 1 and 5 days after TAVI and in ascending aorta during the procedure.

Interventions

OTHERtest

Peripheral venous citrated blood will be collected just before and 10-15 min after the implantation of the valve. Samples will be obtained after starting the infusion of contrast media. In peripheral venous blood before 24 h and after the procedure and at hospital discharge, 4-6 days when the usual transient thrombocytopenia after TAVI has recovered. The results will be used to analyse the kinetics of haematological changes in peripheral blood following aortic valve replacement. Platelet activation will be monitored by flow cytometry to assess the expression of specific membrane markers and the phosphorylation of signalling proteins, as well as the formation of platelet/monocyte aggregates.

OTHERcontrol group

In this group, only one sample (2 tubes filled with 4.5 ml, i.e. 9ml) will be obtained in venous peripheral blood to establish reference values in age-matched, aspirin-treated, atherosclerotic population.

Sponsors

Medtronic
CollaboratorINDUSTRY
University Hospital, Toulouse
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
50 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Test group * Severe symptomatic AS (Aortic valve area \< 0,6 cm2/m2 SC), deemed, after multidisciplinary heart team evaluation, contra-indicated or at high risk for surgery and suitable for TF TAVI with a MCV prosthesis. * Aspirin treatment (75-160 mg/d for at least one week) * Control group * Stable coronary artery disease, unscathed of AS * Aspirin treatment (75-160 mg/d for at least one week)

Exclusion criteria

* Test group: * Acute coronary syndrome 1 month before inclusion * Any co-morbidity limiting life-expectancy \< 1 year * Terminal chronic kidney disease requiring hemodialysis thrombocytopenia \<100 G/L, anemia (Hb \< 10 g/dl) * Treatment by another antiplatelet agent within 10 days before the procedure * Control group: * Acute coronary syndrome 1 month before inclusion * Any co-morbidity limiting life-expectancy \< 1 year * Terminal chronic kidney disease requiring hemodialysis * Thrombocytopenia \<100 G/L * Treatment by another antiplatelet agent within 10 days before the procedure

Design outcomes

Primary

MeasureTime frameDescription
the change of kinetics of platelet activation1 min before TAVI and at days 1after TAVIEvaluate the kinetics of platelet activation before and at various times after valve implantation, by comparing several specific markers in peripheral venous blood samples before (day 0) and at day 1 after the procedure using flow cytometry (FACS).

Secondary

MeasureTime frameDescription
Changes of platelet activation1 min before and 10 min after TAVIplatelet activation in aortic blood downstream of the stenotic valve before and 10 min after TAVI,
Changes of platelet activity1 min before and day 1 after TAVIplatelet reactivity to selected agonists in peripheral venous blood samples before and at days 1 and 5±1. Measure of platelet/monocytes aggregates by flow cytometry approaches. Measure of plasma serotonin and soluble GPIV by an by an ELISA technique
changes in von Willebrand factor1 min before and day 1 and 5 after TAVIchanges in von Willebrand factor in peripheral blood samples The activity and level of vWF antigen will be measured by immunotubidimetric methods

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026