Analysis of Deposition With Nebulizers Membrane

ANALYSIS OF DEPOSITION RADIOAEROSOL NEBULIZERS MEMBRANE IN HEALTHY SUBJECTS

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02501655
Enrollment
15
Registered
2015-07-17
Start date
2015-07-31
Completion date
2015-08-31
Last updated
2015-07-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Healthy Volunteers

Brief summary

BACKGROUND: Mesh nebulizers (MN) have lower residual volume and increased inhaled dose compared to jet nebulizers (JN) per in vitro and animal models. The aim of this study was to compare radioaerosol deposition using MN and JN in healthy subjects, using 2-D planar scintigraphy. METHODS: A randomized trial in 6 normal subjects (4 female, 2 male) inhaled 99mTc-DTPA with an activity of 1 mCi with the normal saline to a total dose of 4 mL with JN (Misty Max, Air Life, Yorba Linda, USA) oxygen flow of 8 L / min and 1.5 mL with MN (Aeroneb Solo with Ultra adapter; Aerogen Galway, Ireland). Scintigraphy was used to determine distribution of deposition and mass balance between compartments.

Interventions

DEVICEphase 1 - jet nebulizer

Aerosol generators diethilene penta-acetic triamine technetium (99mTc-DTPA) with radioactivity of 1 millicuries (Noble et al., 2007) mixed with 0.9% saline solution with a total volume of 4 ml using jet nebulizer (NS - mark) and 8l/min of the oxygen

DEVICEPhase 2- mesh nebulizer

Aerosol generators diethilene penta-acetic triamine technetium (99mTc-DTPA) with radioactivity of 1 millicuries (Noble et al., 2007) mixed with 0.9% saline solution with a total volume of 2 ml using vibrating mesh inhaler with valved chamber adapter (Aerogen Solo with Ultra Adapter, Aerogen Ltd).

Sponsors

Daniella Cunha Brandao
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

* The study inclusion critera was healthy adults of both sexes, between 18 to 65 years, without history of lung disease or smoking, with forced vital capacity (FVC) or forced expiratory volume in the first second (FEV1) greater or equal to 80% of predicted values (Pereira et al., 1992), ability to follow and retain verbal commands while able and willing to provide signed consent to participate in this study.

Exclusion criteria

* Participants were excluded if they have been diagnosed with a lung disease, current smoker, unable to understand and follow the procedures and pregnant or unable to tolerate nebulization.

Design outcomes

Primary

MeasureTime frameDescription
radioaerosol deposition index into the lungs1 monthImmediately after inhalation, participants sat in a chair with the back positioned in front to the gamma camera (STARCAM 3200 GE, California, USA) to obtain radioactivity counts from the posterior thorax during a period of 300 seconds on a matrix of 256 X 256. After, participants were positioned sitting in front to the gama camera to obtain images from face. Then, the same procedure was performed to analysis deposition in the nebulizer, circuits, inspiratory filter, expiratory filter and face mask. Counts representing stomach were obtained from posterior thorax and corrections for decay of technetium were used to during extrapulmonary measurements

Countries

Brazil

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026