Skip to content

Rapid Immunoassay Tests for the Detection of Ruptured Membranes

A Comparison of Rapid Immunoassay Tests for the Detection of Ruptured Membranes

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02495441
Enrollment
100
Registered
2015-07-13
Start date
2015-08-31
Completion date
2016-08-31
Last updated
2015-08-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Premature Rupture of Membranes

Brief summary

The aim of the study is to demonstrate substantial equivalence of IGFBP-1/AFP tests with the predicate device Amnisure® in detecting pre labor rupture of membranes. 4 test kits are compared against a common referent standard (gold standard), which is clinical assessment.

Detailed description

Premature rupture of membranes (PROM) is defined as spontaneous rupture of membranes (ROM) before the onset of uterine contractions. Its diagnosis is often obvious with the woman presenting with leakage of amniotic fluid, but it could also turn out to be a difficult diagnostic dilemma. The diagnosis of fetal membrane rupture is conventionally made using a clinical assessment. First, by speculum examination, the clinician looks for amniotic fluid leaking from the cervical os. If clear fluid is visualized leaking from the cervical os, the diagnosis is positive for fetal membrane rupture. More commonly, leaking is absent, and a more extensive workup is required, which includes nitrazine/pH testing, visual inspection of pooling of fluid in the posterior fornix, and a microscopic evaluation of the collected specimen (ferning). Although this approach is considered the standard of care, it is fraught with inaccuracies, requires an intrusive examination and may not provide a rapid diagnosis. Rapid, point of care, qualitative immunochromatographic tests (ie., Amnisure®, ActimProm®, Amnioquick® Complete and ROM Plus®) that detect proteins found in amniotic fluid at high concentrations, have been used to diagnose the rupture of membranes (ROM) for several years. In many hospitals, Amnisure® has replaced the sterile speculum exam as the standard of care for diagnosing ROM. It identifies Placental Alpha Microglobulin-1 (PAMG-1), a 34 kd fetal glycoprotein, in cervicovaginal secretions. ROM Plus® ActimProm®and Amnioquick® Complete+ are newer additions into the market for testing for PROM. Both these tests use a monoclonal/polyclonal antibody approach to detect two different proteins found in amniotic fluid at high concentrations. They detect Placental Protein-12 (also known as Insulin-like Growth Factor Binding Protein-1 - IGFBP-1) as well as Alpha Fetoprotein (AFP). The aim of the study is to demonstrate substantial equivalence of IGFBP-1/AFP tests with the predicate device Amnisure®. Stated in statistical terms, the aim is to demonstrated that IGFBP-1/AFP tests are non-inferior to Amnisure® in terms of sensitivity and specificity when both are compared in a paired-sample fashion to a common referent standard (gold standard), which is clinical assessment.

Interventions

After informed consent , both the ROM Plus®, ActimProm Amnioquick® Complete and AmniSure® bedside tests (without the use of a speculum) will be performed. The patient will then undergo the standard clinical assessment, which includes a sterile speculum exam (SSE). If either 1) amniotic fluid is seen leaking from the cervical os, or 2) if at least two of the following three clinical signs are present: visual pooling of fluid in the posterior fornix, positive nitrazine test, and microscopic evidence of ferning, then the patient will be considered positive for ROM. Women who cannot be confirmed clinically by the SSE will undergo an ultrasound evaluation to determine the amniotic fluid index. The patient will be treated according to the results of the SSE and ultrasound, not the results of IGFBP-1/AFP tests and Amnisure®.

Sponsors

Clinical Innovations, LLC
CollaboratorINDUSTRY
De Soysa Hospital for Women
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Healthy volunteers
No

Inclusion criteria

* Any woman who presents with alleged leakage of amniotic fluid is eligible for recruitment

Exclusion criteria

* Known placental previa * Active vaginal bleeding

Design outcomes

Primary

MeasureTime frameDescription
Number of participants that become positive for pre labor rupture of membranes by the immunological test kits.up to 1 yearThis will be assessed by the performing 4 immunological tests and clinical assessment. These test kits includes ROM Plus, ActimProm®, Amnioquick® and Amnisure. Outcomes of the immune tests will be compared against a gold stranded clinical assessment.

Countries

Sri Lanka

Contacts

Primary ContactHemantha Senanayake, MS, FRCOG
senanayakeh@gmail.com,+94714762176

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026