Skip to content

The Holding Area LINQ (Reveal LINQ Insertable Cardiac Monitor) Trial is a Prospective, Non-randomized, Single Center Post-market Clinical Trial

The Holding Area LINQ Trial is a Prospective, Non-randomized, Single Center Post-market Clinical Trial Designed to Occur in the Holding Area of a Hospital Operating Room or Cardiac Catheterization/Electrophysiology Laboratory

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02493205
Acronym
HALT
Enrollment
20
Registered
2015-07-09
Start date
2015-06-30
Completion date
2016-11-30
Last updated
2022-01-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Keywords

Implantable Cardiac Monitor, Stent

Brief summary

The Holding Area LINQ Trial is a clinical trial designed to compare the benefits in conducting impant procedures in the holding area of a hospital operating room vs cardiac catheterization/electrophysiology laboratory.

Detailed description

The Holding Area LINQ Trial is a prospective, non-randomized, single center post-market clinical trial designed to occur in the holding area of a hospital operating room or cardiac catheterization/electrophysiology laboratory. The primary objective is to characterize the rate of procedure-related complications within 90 days of the implant procedure which require resolution by surgical intervention. Twenty (20) patients with established clinical indications for the LINQ ICM (Reveal LINQ Insertable Cardiac Monitor) will be implanted using standard of care techniques and procedures. Implants will be required to take place in a hospital holding area rather than the traditional facility locations such as the hospital operating room, cardiac catheterization lab, or electrophysiology lab. A physical description of the holding area is a small patient examination room separated from other patient exam bay by walls and a door. There is a sink in the patient exam room, laminate flooring, ceiling A/C vent, wall mounted Hemodynamic monitoring equipment, and wall mounted oxygen/suction lines. Patient sedation will be limited to local anesthetics and/or oral anti-anxiety medications. Intravenous access will be obtained only for emergency resuscitative measures. Due to the low complication rate for this type of implant and practical limitations on the sample size, there are no formal hypotheses tested in this trial. This study will characterize all procedure-related adverse events that occur within 90 days of the implant procedure. Data will be collected at implant, 7-10 day post-op visit, and 90-day post-implant visits.

Interventions

None listed

Sponsors

Medtronic
CollaboratorINDUSTRY
Holy Cross Hospital, Florida
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patient is indicated for continuous arrhythmia monitoring with an Implantable Cardiac Monitor 2. Patient is willing to undergo implant in holding area setting with only local anesthetic and/or oral anti-anxiety medications for sedation (2 mg of Valium or Ativan) at patient request. 3. Patient is 18 years of age or older. 4. Patient is willing to provide informed consent and authorize disclosure of personal health information in accordance with state and national regulations.

Exclusion criteria

1. Patient has reduced immune function or is otherwise at high risk for infection 2. Patient has had a recent (within 30 days) or otherwise unresolved infection. 3. Patient is implanted or indicated for implant with a pacemaker, Implantable Cardiac Device (ICD), Cardiac Resyncronization Therapy (CRT) or hemodynamic monitoring system. 4. Patient is participating in another clinical trial that may have an impact on the trial endpoints. 5. Patient has a super-therapeutic INR \> 3.0. 6. Patient considered by Principal Investigator and/or sub-investigator to be inappropriate for the trial for any reason. 7. Patient's life expectancy is less than 1 year. 8. Patient is pregnant. 9. Patient has an unusual thoracic anatomy or scarring at the implant site which may adversely affect the success of the implant procedure. 10. Inability to comply with planned trial procedures

Design outcomes

Primary

MeasureTime frameDescription
Rate of procedure-related complications within 90 days of implant which require resolution by surgical intervention.90 days post-implant.-For this study there is no formal hypothesis or performance criterion tested for this objective. Instead, the rate of these complications will be characterized by computing a point estimate and one-sided upper 95% confidence interval for the rate of procedure-related complications requiring surgical intervention 90 days post-implant-

Secondary

MeasureTime frameDescription
Cost-effectiveness for LINQ ICM holding area implants.90 days Post ImplantProcedure duration as well as the types of personnel and resources needed for LINQ implant will be collected on the implant case report form. This information will be summarized using summary statistics and/or graphical methods.
Device functionality post-implant through patient trial exit visit.90 Days Post ImplantDevice functionality post-implant will be characterized by collecting R-wave amplitudes on the day of implant and at the 90-day follow-up visit. Following each implant, R-wave amplitude will be collected and recorded on the Implant e-CRF. In addition, R-wave amplitude will be collected and recorded at the 90-day follow-up visit or at an unscheduled visit should the patient exit the study prior to the 90-day follow-up visit. Summary statistics and/or graphical methods will be used to summarize the R-wave amplitude.
Resource utilization for LINQ ICM holding area implants.90 Days Post ImplantProcedure duration as well as the types of personnel and resources needed for LINQ implant will be collected on the implant case report form. This information will be summarized using summary statistics and/or graphical methods.
Procedures utilized during LINQ ICM holding area implants.90 Days Post ImplantProcedure duration as well as the types of personnel and resources needed for LINQ implant will be collected on the implant case report form. This information will be summarized using summary statistics and/or graphical methods.
Techniques utilized during LINQ ICM holding area implants.90 Days Post ImplantProcedure duration as well as the types of personnel and resources needed for LINQ implant will be collected on the implant case report form. This information will be summarized using summary statistics and/or graphical methods.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026