Noninvasive Subharmonic Aided Pressure Estimation of Portal Hypertension

Noninvasive Subharmonic Aided Pressure Estimation of Portal Hypertension

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02489045
Enrollment
178
Registered
2015-07-02
Start date
2015-04-06
Completion date
2019-03-31
Last updated
2021-08-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Liver Diseases, Portal Hypertension

Brief summary

This is an open-label, non-randomized trial that will be conducted at two clinical sites, Thomas Jefferson University (TJU) and the Hospital of the University of Pennsylvania (HUP). Enrolled patients undergoing trans-jugular liver biopsy with hepatic vein pressure gradient (HVPG) measurements will receive a continuous infusion of Sonazoid® (GE Healthcare, Oslo, Norway) co-infused with 0.9% NaCl solution over a 5-10 minute time period. Ultrasound imaging will be performed using a Logiq 9 scanner with a 4C transducer (GE Healthcare, Milwaukee, WI) and the novel SHAPE (subharmonic aided pressure estimation) algorithm will be used to measure pressure values in the hepatic and portal veins. Data will be stored on a PC and compared to pressure-catheter measurements, Subjects identified in the initial examination as having portal hypertension (by HVPG results) will be monitored by SHAPE for up to 18 months. These subjects typically have surveillance Computed tomography (CT) or magnetic resonance imaging (MRI) scans every 6 months to screen for liver cancer, and at those times a repeat SHAPE examination will be performed (ideally within 1 month of their clinically indicated imaging follow up appointment). In patients who undergo more frequent screening (generally 3 month intervals), SHAPE exams will be performed at 6 month intervals. Any repeat trans-jugular liver biopsies performed in this population will also trigger a repeat SHAPE study. Results of blood test evaluations (performed every 3 months in this population), medication, concomitant imaging study or procedure (including endoscopies) will be noted (all blood tests and imaging are clinically indicated only and are not required by this protocol). The end point for this part of the study will be any one new complication (e.g., liver cancer) or a marked worsening in any complication, liver transplantation, death, or the end of this clinical trial (after 3 years). The investigators expect these patients will be monitored three times during the course of this clinical trial. The time to reach the end point will be noted if a new complication or a marked worsening in any complication occurs.

Interventions

Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.

Sponsors

University of Pennsylvania
CollaboratorOTHER
National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)
CollaboratorNIH
Thomas Jefferson University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Be scheduled for trans-jugular liver biopsy the day of the ultrasound procedure. * Be at least 21 years of age. * Be medically stable. * If a female of child-bearing potential, must have a negative pregnancy test. * Be conscious and able to comply with study procedures. * Have read and signed the IRB-approved Informed Consent form for participating in the study.

Exclusion criteria

* Females who are pregnant or nursing. * Patients not scheduled for trans-jugular liver biopsy * Patients who have received an investigational drug in the 30 days before study drug administration, or will receive one within 72 h afterwards,. * Patients with known or suspected right-to-left, bi-directional, or transient right-to-left cardiac shunts * Patients with pulmonary hypertension or unstable cardiopulmonary conditions * Patients currently on chemotherapy or with other primary cancers requiring systemic or hepatic loco-regional treatment. * Patients who are medically unstable, patients who are seriously or terminally ill, and patients whose clinical course is unpredictable. For example: * Patients on life support or in a critical care unit. * Patients with unstable occlusive disease (e.g., crescendo angina) * Patients with clinically unstable cardiac arrhythmias, such as recurrent ventricular tachycardia. * Patients with uncontrolled congestive heart failure (NYHA Class IV) * Patients with recent cerebral hemorrhage. * Patients who have undergone surgery within 24 hours prior to the study sonographic examination. * Patients with a history of anaphylactic allergy to eggs or egg products, manifested by one or more of the following symptoms: generalized urticaria, difficulty in breathing, swelling of the mouth and throat, hypotension, or shock. (Subjects with nonanaphylactic allergies to eggs or egg products may be enrolled in the study, but must be watched carefully for 1 h following the administration of SONAZOID). * Patients with congenital heart defects. * Patients with severe emphysema, pulmonary vasculitis, or a history of pulmonary emboli. * Patients with respiratory distress syndrome * Patients with thrombosis within the hepatic, portal, or mesenteric veins.

Design outcomes

Primary

MeasureTime frameDescription
Diagnostic Accuracy of SHAPE Liver Pressure Estimates (in dB) for Diagnosing Portal Hypertension With Catheter Pressure Measurements (in mmHg) as the Reference Standardup to 1 dayEvaluate the use of in vivo subharmonic aided pressure estimation (SHAPE as the difference between the optimized subharmonic signal in a hepatic vein and in the portal vein) as a first quantitative screening modality for determining the presence of clinically significant portal hypertension in patients undergoing a transjugular liver biopsy compared to catheter based hepatic-venous pressure gradient measurements (HVPG in mmHg as the reference standard).
SHAPE Liver Pressure Estimates (in dB) Correlation With Catheter Pressure Measurements (in mmHg)up to 1 dayEvaluate the correlation between in vivo subharmonic aided pressure estimation (SHAPE as the difference between the optimized subharmonic signal in a hepatic vein and catheter based hepatic-venous pressure gradient measurements (HVPG in mmHg) in patients undergoing a transjugular liver biopsy.
Comparing SHAPE Results With Blood Work and Concomitant Imaging in Portal Hypertension Patientsup to 2 hoursDetermine if SHAPE measurements (in dB) can provide a quantitative, noninvasive measurement of hepatic venous pressure gradient (HVPG) to monitor disease progression or treatment response in patients identified with portal hypertension by comparing the results to repeat biopsies and/or clinical outcomes.

Countries

United States

Participant flow

Participants by arm

ArmCount
SHAPE Measurement
48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min. SHAPE measurement (Sonazoid ultrasoud contrast agent): Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
125
Total125

Withdrawals & dropouts

PeriodReasonFG000
Follow-upLost to Follow-up10
Overall Studyunable to collect usable data53

Baseline characteristics

CharacteristicSHAPE Measurement
Age, Continuous58 years
STANDARD_DEVIATION 12
Ethnicity (NIH/OMB)
Hispanic or Latino
4 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
121 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
5 Participants
Race (NIH/OMB)
Black or African American
41 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
79 Participants
Region of Enrollment
United States
125 participants
Sex: Female, Male
Female
45 Participants
Sex: Female, Male
Male
80 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 125
other
Total, other adverse events
0 / 125
serious
Total, serious adverse events
0 / 125

Outcome results

Primary

Comparing SHAPE Results With Blood Work and Concomitant Imaging in Portal Hypertension Patients

Determine if SHAPE measurements (in dB) can provide a quantitative, noninvasive measurement of hepatic venous pressure gradient (HVPG) to monitor disease progression or treatment response in patients identified with portal hypertension by comparing the results to repeat biopsies and/or clinical outcomes.

Time frame: up to 2 hours

Population: Only subjects with clinically significant portal hypertension were included in the follow-up study

ArmMeasureGroupValue (MEAN)Dispersion
SHAPE MeasurementComparing SHAPE Results With Blood Work and Concomitant Imaging in Portal Hypertension PatientsSHAPE values in responders-4.01 dBStandard Deviation 3.61
SHAPE MeasurementComparing SHAPE Results With Blood Work and Concomitant Imaging in Portal Hypertension PatientsSHAPE value in non-responders2.33 dBStandard Deviation 0
Primary

Diagnostic Accuracy of SHAPE Liver Pressure Estimates (in dB) for Diagnosing Portal Hypertension With Catheter Pressure Measurements (in mmHg) as the Reference Standard

Evaluate the use of in vivo subharmonic aided pressure estimation (SHAPE as the difference between the optimized subharmonic signal in a hepatic vein and in the portal vein) as a first quantitative screening modality for determining the presence of clinically significant portal hypertension in patients undergoing a transjugular liver biopsy compared to catheter based hepatic-venous pressure gradient measurements (HVPG in mmHg as the reference standard).

Time frame: up to 1 day

ArmMeasureValue (NUMBER)
SHAPE MeasurementDiagnostic Accuracy of SHAPE Liver Pressure Estimates (in dB) for Diagnosing Portal Hypertension With Catheter Pressure Measurements (in mmHg) as the Reference Standard95 diagnostic accuracy in percent
Primary

SHAPE Liver Pressure Estimates (in dB) Correlation With Catheter Pressure Measurements (in mmHg)

Evaluate the correlation between in vivo subharmonic aided pressure estimation (SHAPE as the difference between the optimized subharmonic signal in a hepatic vein and catheter based hepatic-venous pressure gradient measurements (HVPG in mmHg) in patients undergoing a transjugular liver biopsy.

Time frame: up to 1 day

ArmMeasureValue (NUMBER)
SHAPE MeasurementSHAPE Liver Pressure Estimates (in dB) Correlation With Catheter Pressure Measurements (in mmHg)0.68 correlation coefficient

Source: ClinicalTrials.gov · Data processed: Feb 17, 2026