Skip to content

Alterations of Conjunctival Microcirculation in Brain Dead Patients

Alterations of Conjunctival Microcirculation in Brain Dead Patients

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02483273
Enrollment
22
Registered
2015-06-26
Start date
2011-05-31
Completion date
2016-03-31
Last updated
2016-03-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Brain Death

Keywords

Conjunctival microcirculation, Sublingual microcirculation, Sidestream Dark Field (SDF) microscopy

Brief summary

Study hypothesize that ocular microcirculation is reflecting cerebral perfusion. The purpose of this study is to evaluate ocular microcirculation in brain dead patients using side dark field (SDF) videomicroscope and compare it with microcirculatory parameters of healthy volunteers.

Detailed description

Microcirculation videomicroscopy techniques are used to evaluate a global organ perfusion in various critical conditions using limited suitable sites available for visualisation. However, ocular microcirculation may become a window to specifically cerebral perfusion due to related blood supply, close anatomical proximity and easy accessibility for videomicroscopy. Cerebral perfusion mainly depends on cerebral flow and intracranial pressure and therefore we aim, for the first time, to demonstrate microcirculatory status of ocular conjunctiva in clinical conditions when cerebral flow is completely absent. In a single center open label observational study investigators analyzed conjunctival and sublingual microcirculation using SDF videomicroscopy in brain dead patients after reaching systemic hemodynamic targets to optimise perfusion of donor organs. All brain death diagnoses were confirmed by cerebral angiography. Microcirculatory images obtained and analyzed using standardized published recommendations by experts in this field. Microcirculation of sublingual and conjunctival areas were recorded in matching number of healthy volunteers using same techniques.

Interventions

None listed

Sponsors

Lithuanian University of Health Sciences
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Diagnosed brain dead

Exclusion criteria

* Conjunctival or sublingual mucosa damage

Design outcomes

Primary

MeasureTime frameDescription
Microvascular flow index (MFI) of ocular conjunctiva.After confirmed diagnosis of brain death of any course using cerebral angiography at any time up to 24 hours.Conjunctival convective oxygen transport presented as MFI of small vessels mostly capillaries with diameter cutoff value of 20µm. Images of microcirculation were taken from at least three different points in each ocular conjunctiva and recorded for at least 20 seconds avoiding pressure artifacts. Microcirculation images were obtained using SDF videomicroscopy (Microscan®, Microvision Medicals, Amsterdam, Netherlands). Data recorded to the hard drive of personal computer using AVA 3.0v software (Microvision Medical, Amsterdam, Netherlands). Video clips were then randomly blinded and later analyzed by 2 independent investigators.
Total vessel density (TVD) of ocular concunctiva.After confirmed diagnosis of brain death of any course using cerebral angiography at any time up to 24 hours.Conjunctival microvascular diffusion distance presented as TVD (mm/mm²) of small vessels mostly capillaries with diameter cutoff value of 20µm. Images of microcirculation were taken from at least three different points in each ocular conjunctiva and recorded for at least 20 seconds avoiding pressure artifacts. Microcirculation images were obtained using SDF videomicroscopy (Microscan®, Microvision Medicals, Amsterdam, Netherlands). Data recorded to the hard drive of personal computer using AVA 3.0v software (Microvision Medical, Amsterdam, Netherlands). Video clips were then randomly blinded and later analyzed by 2 independent investigators.
Perfused vessel density (PVD) of ocular conjunctiva.After confirmed diagnosis of brain death of any course using cerebral angiography at any time up to 24 hours.Conjunctival microvascular diffusion distance presented as PVD (mm/mm²) of small vessels mostly capillaries with diameter cutoff value of 20µm. Images of microcirculation were taken from at least three different points in each ocular conjunctiva and recorded for at least 20 seconds avoiding pressure artifacts. Microcirculation images were obtained using SDF videomicroscopy (Microscan®, Microvision Medicals, Amsterdam, Netherlands). Data recorded to the hard drive of personal computer using AVA 3.0v software (Microvision Medical, Amsterdam, Netherlands). Video clips were then randomly blinded and later analyzed by 2 independent investigators

Secondary

MeasureTime frameDescription
Microvascular flow index (MFI) of sublingual mucosa.After confirmed diagnosis of brain death of any course using cerebral angiography at any time up to 24 hours.Sublingual mucosa convective oxygen transport presented as MFI of small vessels mostly capillaries with diameter cutoff value of 20µm. Images of microcirculation were taken from at least three different points in sublingual mucosa and recorded for at least 20 seconds avoiding pressure artifacts. Microcirculation images were obtained using SDF videomicroscopy (Microscan®, Microvision Medicals, Amsterdam, Netherlands). Data recorded to the hard drive of personal computer using AVA 3.0v software (Microvision Medical, Amsterdam, Netherlands). Video clips were then randomly blinded and later analyzed by 2 independent investigators.
Total vessel density (TVD) of sublingual mucosa.After confirmed diagnosis of brain death of any course using cerebral angiography at any time up to 24 hours.Sublingual mucosa microvascular diffusion distance presented as TVD (mm/mm²) of small vessels mostly capillaries with diameter cutoff value of 20µm. Images of microcirculation were taken from at least three different points in sublingual mucosa and recorded for at least 20 seconds avoiding pressure artifacts. Microcirculation images were obtained using SDF videomicroscopy (Microscan®, Microvision Medicals, Amsterdam, Netherlands). Data recorded to the hard drive of personal computer using AVA 3.0v software (Microvision Medical, Amsterdam, Netherlands). Video clips were then randomly blinded and later analyzed by 2 independent investigators.
Perfused vessel density (PVD) of sublingual mucosa.After confirmed diagnosis of brain death of any course using cerebral angiography at any time up to 24 hours.Sublingual mucosa microvascular diffusion distance presented as PVD (mm/mm²) of small vessels mostly capillaries with diameter cutoff value of 20µm. Images of microcirculation were taken from at least three different points in sublingual mucosa and recorded for at least 20 seconds avoiding pressure artifacts. Microcirculation images were obtained using SDF videomicroscopy (Microscan®, Microvision Medicals, Amsterdam, Netherlands). Data recorded to the hard drive of personal computer using AVA 3.0v software (Microvision Medical, Amsterdam, Netherlands). Video clips were then randomly blinded and later analyzed by 2 independent investigators.

Countries

Lithuania

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 12, 2026