Skip to content

A Comparison of Optical Coherence Tomography Guidance and Angiography-only Guidance for Percutaneous Coronary Intervention With Bioresorbable Vascular Scaffold

A Randomized Controlled Comparison of Optical Coherence Tomography Guidance and Angiography-only Guidance for Percutaneous Coronary Intervention With Bioresorbable Vascular Scaffold

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02466282
Enrollment
13
Registered
2015-06-09
Start date
2015-06-30
Completion date
2016-06-30
Last updated
2016-07-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Brief summary

It is well-known that non-optimal stent implantation associated with under-expansion or incomplete strut apposition during percutaneous coronary intervention (PCI) leads to a higher incidence of restenosis and stent thrombosis. OCT-guided PCI with metallic stent has previously been shown to be safe and feasible, resulting in better clinical outcomes compared with angiography-only guided PCI. Everolimus-eluting bioabsorbable vascular scaffold (BVS; Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. BVS has a number of proposed advantages over current metallic stent technology. These include elimination of chronic sources of vessel irritation and inflammation, which can reduce the potential risk of late scaffold thrombosis after complete scaffold bioresorption. Although the current generation of the Absorb BVS have larger strut thickness of 150 μm compared with 80 μm of strut of Xience stent, the acute recoil of the polymeric device was similar to that of metallic stent. However, operators tented to use dilating devices less aggressively because of the concerns about limitation in elongation-at-break of polylactide. Previous studies reported 20-30% of under-expansion or malapposition with BVS, which would increase the risk of adverse events including late stent thrombosis. OCT-guidance may improve more optimized scaffold placement and also better outcomes. Therefore, investigators will compare OCT guidance and angiography-only guidance for PCI with BVS regarding incomplete scaffold apposition and neointimal scaffold coverage. Investigators are also going to compare these two strategies regarding clinical outcomes with verification of the cut-off value by OCT-acquired uncovered scaffold rate.

Interventions

DEVICEAngiography-guided PCI with bioresorbable vascular scaffold

Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. PCI will be performed with BVS under conventional coronary angiography without any other intravascular imaging modality.

DEVICEoptical coherence tomography-guided PCI with bioresorbable vascular scaffold

Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. For optimized PCI, both conventional coronary angiography and optical coherence tomography can be used before and after stent implantation. OCT study should be checked at the final post-procedure and stent implantation is optimized.

Sponsors

Yonsei University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
19 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients ≥ 19 years old * Patients with ischemic heart disease who are considered for coronary revascularization with PCI * Significant coronary de novo lesion (stenosis \> 70% by quantitative angiographic analysis) treated by single BVS ≤ 25mm * Reference vessel diameter of 2.5 to 3.5 mm by operator assessment

Exclusion criteria

* Myocardial infarction * Complex lesion morphologies such as aorta-ostial, unprotected left main, chronic total occlusion, graft, thrombosis, and restenosis * Reference vessel diameter \<2.5 mm or \>3.5 mm * Heavy calcified lesions (definite calcified lesions on angiogram) * Lesions requiring 2 or more BVS * Contraindication or hypersensitivity to anti-platelet agents or contrast media * Treated with any metallic stent or BVS within 3 months at other vessel * Creatinine level ≥ 2.0 mg/dL or ESRD * Severe hepatic dysfunction (3 times normal reference values) * Pregnant women or women with potential childbearing * Inability to follow the patient over the period of 1 year after enrollment, as assessed by the investigator * Inability to understand or read the informed content

Design outcomes

Primary

MeasureTime frameDescription
Percentage of uncovered scaffold strutssix monthsPercentage of uncovered scaffold struts between OCT guidance vs. angiography-only guidance PCI on 6 month OCT

Secondary

MeasureTime frameDescription
Major cardiac and cerebrovascular adverse events (MACCEs)until one yearCardiac death, myocardial infarction, target vessel revascularization, stent thrombosis, cerebrovascular accident and major bleeding between OCT guidance vs. angiography-only guidance PCI until 12 months \*Major bleeding ; causing mortality, hypovolemic shock or severe hypotension requiring inotropes or surgery, intrapericardial with tamponade, significant disabling (e.g. intraocular bleeding leading to loss of vision), symptomatic intracranial haemorrhage, intraocular bleeding leading to loss of vision, hemoglobin drop ≥ 3g/dL, or requiring transfusion more than 2 units
Percentage of incomplete scaffold struts appositionsix months after stent implantationScaffold strut malapposition: Malapposition is defined by a clear seperation between the abluminal side of the strut and the vessel wall. As a result, scaffold malapposition is defined as the presence of any malapposed struts. percentage of malapposed struts (% malapposed strut) was the ratio of malapposed struts from total analyzable struts.

Countries

South Korea

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026