Skip to content

The Efficacy and Safety of Magnesium Alloy Screw as a Novel Bioabsorbable Material in Patients Due to Hand Fractures

A Prospective, Single Center, Single Group, Open-label Study to Evaluate the Efficacy and Safety of Magnesium Alloy Screw as a Novel Bioabsorbable Material in Patients Requiring Internal Fixation Due to Hand Fractures

Status
Completed
Phases
Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02456415
Enrollment
28
Registered
2015-05-28
Start date
2013-07-31
Completion date
2014-12-31
Last updated
2015-09-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hand Fractures

Brief summary

This study evaluates the safety and efficacy of biodegradable magnesium alloy screw, in patients with hand fractures who require internal fixation (to obtain a product license from the Ministry of Food and Drug Safety in Korea (MFDS)).

Detailed description

Rationale: Hand fractures including intra- and extra-articular phalanges and metacarpal are common and account for approximately 40% of upper extremity fractures and lead to functional loss of the hand.Fractures can be treated conservatively with a nonsurgical approach(Closed reduction) by placing the damaged figure in a splint; this may results in displacement, rotation, angulation and/or instability, therefore require surgery. Surgical techniques for treatment of hand fractures include internal fixation with metal plate or screws after Open reduction and external fixation with insertion of percutaneous pins or screws. Percutaneous external fixation is one of the widely used methods, but is difficult to maintained when accompanied by unstable fractures and soft tissue injuries or there are severely comminuted fractures and sometimes results in restricted motion of adjacent joints due to prolonged fixation. In comparison, internal fixation is an operation using internal fixators such as plates, wires, screws etc. solely or concurrently depending on the location and severity of hand fracture. With the recent advancement of implant design and fixation techniques, a variety of screws are widely used for fixation of small-bone fractures. The present study was designed to evaluate the efficacy and safety of magnesium alloy screw as a novel bioabsorbable and biodegradable material. Study Duration: After an approval of clinical protocol from MFDS in Korea, total 20 months were required including 14 months for subject enrollment and 6 months of follow-up. An additional 1 month was required after completion of the study for handling of data, statistical analysis and preparation of study report. Target Subjects: Patients who require internal fixation using screws due to hand fractures Investigational Device: K-MET™ Bioresorbable Bone screw (manufactured by U&I) This device divided into two type,Cortex screw and Headless compression screw. Number of Subjects: A total of 34 cases of bone fractures in 28 subjects.

Interventions

DEVICEK-MET™ Bioresorbable Bone screw

The biodegradable screw inserted into bone with an appropriate driver is slowly degraded and is completely degraded after completion of bone union and absorbed into the body. The screw is indicated for fixing damaged bone.

Sponsors

U&I Corporation
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
20 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Male or female patients aged 20 years or older * Patients who require internal fixation using screws in the hand * The clinical features of hand fractures are oblique and spiral fractures * Patients who voluntarily submitted a written informed consent and are willing to and able to follow the clinical study protocol.

Exclusion criteria

* Infections around the fracture site or soft-tissue injury greater than Grade III * Fracture patterns such as open, transverse or comminuted fracture with greater than type II * Fractures that require the use of wires, pins or plates for fixation * Patients with re-fracture * Patients with critical systemic diseases * Patients with renal failure showing plasma creatinine level exceed 1.4 at the screening * Pregnant, lactating women * Patients who have a history of allergy to magnesium alloy * Patients with presence of past illness or taking a drug that may affect bone union * Patients who have participated in other clinical study and treated with medication or other medical device within past 3 months * Patients who are judged not to be appropriate for study enrollment in the opinion of the investigator

Design outcomes

Primary

MeasureTime frameDescription
Bone unionup to 6 monthsBone union was evaluated at 6-month after surgery according to the following definition.Definition of bone union is when simple X-ray findings reveal that bone trabeculae or cortical bone exceeds the fracture site. Non-union is defined as no union at 3-month post-surgery.

Secondary

MeasureTime frameDescription
PROM(Passive Range of Motion)up to 6 monthsThis Passive Range of Motion(PROM) is measured by goniometer and is compared with the value of the normal hand that did not undergo surgery.
TAM(Total Active Motion)up to 6 monthsTotal Active Motion(TAM) is measured by goniometer and is compared with the value of the normal hand that did not undergo surgery.
Power(grip strength and pick-up power)up to 6 monthsThe Power was measured using a dynamometer and pick-up counter and is compared with the value of the hand that did not undergo surgery.
DASH scale3,6 monthsThis questionnaire evaluates the ability of the hand to perform certain activities before and after surgery. It was directly completed by subjects.
Pain as measured by the NRS (1~10)up to 6 monthsThe NRS (1\ 10) was used to measure the level of pain and was compared before and after surgery.

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026