Skip to content

Pyloric Sphincter Pressure and Geometry Assessment Using EndoFlip

Pyloric Sphincter Pressure and Geometry Assessment Using EndoFlip

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02446119
Acronym
PyloEndoFlip
Enrollment
70
Registered
2015-05-18
Start date
2015-05-31
Completion date
2021-06-30
Last updated
2020-08-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Gastroparesis

Brief summary

Gastroparesis is a disorder characterized by symptoms from gastric retention in the absence of mechanical obstruction. Gastric emptying is a highly regulated process reflecting the integration of the propulsive forces of proximal fundic tone and distal antral contractions with the functional resistance provided by the pyloric sphincter. Pylorospasm has been reported in some patients with gastroparesis. This study protocol will assess pyloric sphincter pressure and geometry in patients with gastroparesis and control subjects without symptoms of gastroparesis. The commercially available FDA approved endoscopic functional luminal imaging probe (EndoFLIP) catheter will be used, which measures diameter, pressure, length, and distensibility of gastrointestinal sphincter muscles along the balloon distance. It is used to measure the pressure characteristics of the lower esophageal sphincter during bariatric surgery for obesity, during Heller myotomy for achalasia, and during Nissen fundoplication for gastroesophageal reflux disease. In this study, during upper endoscopy, which is routinely performed under sedation, patients with gastroparesis and controls without gastroparesis symptoms will have their pyloric sphincter assessed with EndoFLIP. After passage of the endoscope into the stomach, the EndoFLIP catheter will be introduced alongside the endoscope and advanced through the pyloric sphincter as visualized endoscopically. The investigators will measure the pressure and contour of the pyloric sphincter using three successive volume distensions of the EndoFLIP balloon (20 ml, 30 ml, 40 ml). The investigators will compare the results between the gastroparesis patients and the control patients without gastroparesis. Through this study, the investigators will better understand the abnormalities of the pyloric sphincter in patients with gastroparesis.

Detailed description

This study protocol will assess pyloric sphincter pressure and geometry in patients with gastroparesis and control subjects without symptoms of gastroparesis. Aims: To determine if there is a subgroup of patients with gastroparesis who have pressure and/or geometric configuration abnormalities of the pyloric sphincter. We will determine this by assessing the pressure, diameter, length, and distensibility of the pyloric sphincter in patients with gastroparesis and in subjects without gastroparesis undergoing upper endoscopy for their clinical evaluation. Hypothesis:The pylorus of patients with gastroparesis has a higher pressure, smaller diameter, and is less distensible than the pylorus of control patients without gastroparesis Methods: The commercially available FDA approved endoscopic functional luminal imaging probe (EndoFLIP) catheter will be used, which measures diameter, pressure, length, and distensibility of gastrointestinal sphincter muscles along the balloon distance. It is used to measure the pressure characteristics of the lower esophageal sphincter during bariatric surgery for obesity, during Heller myotomy for achalasia, and during Nissen fundoplication for gastroesophageal reflux disease. In this study, during upper endoscopy, which is routinely performed under sedation, patients with gastroparesis and controls without gastroparesis symptoms will have their pyloric sphincter assessed with EndoFLIP. After passage of the endoscope into the stomach, the EndoFLIP catheter will be introduced alongside the endoscope and advanced through the pyloric sphincter as visualized endoscopically. The investigators will measure the pressure and contour of the pyloric sphincter using three successive volume distensions of the EndoFLIP balloon (20 ml, 30 ml, 40 ml). The assessment of the pylorus will be done during the upper endoscopy which will take approximately 60 minutes. We will compare the pyloric pressure measurements in patients with gastroparesis to the control patients. This is an observational study, with no intervention. Analysis: The investigators will compare the results between the gastroparesis patients and the control patients without gastroparesis. Through this study, the investigators will better understand the abnormalities of the pyloric sphincter in patients with gastroparesis.

Interventions

DEVICEEndoFLIP

Measurement of pyloric resistance and compliance

Sponsors

Temple University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
Yes

Inclusion criteria

1. Subjects will be of either sex, 18 to 70 years of age. 2. Two groups will be recruited: * First, patients with an established diagnosis of gastroparesis, either diabetic or idiopathic etiology. * Second, control subjects will be nondiabetic patients without gastroparesis or gastroesophageal reflux symptoms undergoing upper endoscopy.

Exclusion criteria

Prior surgery involving the stomach

Design outcomes

Primary

MeasureTime frameDescription
Pyloric pressure60 minutesMeasurement of pyloric pressure using EndoFLIP in patients with gastroparesis and controls. Our plan is to compare the pyloric pressures in patients with gastroparesis to controls. This is an observational study with no intervention.

Countries

United States

Contacts

Primary ContactHenry P. Parkman, MD
henry.parkman@temple.edu215-707-9900
Backup ContactAmiya Palit
amiya.palit@temple.edu215-707-5477

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026