Skip to content

Cardiac Output by Nine Different Pulse Contour Algorithms

Estimation of Cardiac Output by Nine Different Pulse Contour Algorithms Compared With Transpulmonary Thermodilution

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02438228
Enrollment
30
Registered
2015-05-08
Start date
2014-11-30
Completion date
2015-11-30
Last updated
2016-02-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Output

Keywords

cardiac output, transpulmonary thermodilution, pulse contour analysis, G09.330.380.124

Brief summary

The aim of the present study is to compare accuracy and precision of Cardiac Output (CO) by nine different pulse contour algorithms with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB).

Detailed description

After induction of anesthesia, a central venous catheter and a transpulmonary thermodilution catheter (Pulsion Medical Systems, Munich, Germany) are introduced in the right internal jugular vein and in the femoral artery, respectively. The thermodilution catheter is connected to a PiCCO2 monitor (Software version 1.3.0.8). Thereafter, placement of an esophageal doppler probe is performed and the probe is connected to a unique Monitoring System (Deltex Medical, Chichester, UK) with nine different pulse contour algorithms. Cardiac Output by esophageal doppler is used to calibrate the nine different pulse contour algorithms. After induction of anesthesia and establishment of all monitoring devices, a passive leg raising maneouvre (PLR) is performed and hemodynamic variables including CO by transpulmonary thermodilution (COTPTD) and CO by nine different pulse contour algorithms (COX1-9) are recorded before, during and after PLR. Subsequently, measurements of COTPTD and COX1-9 are carried out every 10 minutes until the beginning of CPB. Fifteen minutes after weaning from cardiopulmonary bypass calibration of nine different pulse contour algorithms by esophageal doppler are performed again and measurements of CITPTD and CIPFX are restarted up to the end of the surgical Intervention.

Interventions

Measurement of cardiac output by transpulmonary thermodilution, nine different pulse contour algorithms and esophageal doppler before, during and after a PLR-maneouvre and every 10 minutes before and after cardiopulmonary Bypass.

Sponsors

University Hospital Schleswig-Holstein
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients \> 18 years of age with a left ventricular ejection fraction ≥ 0.5. * Patients undergoing coronary artery bypass grafting.

Exclusion criteria

* Patients \<18 years of age and with a left ventricular ejection fraction ≤0.5 are not considered for the study. * Emergency procedures and patients with hemodynamic instability requiring continuous pharmacologic support, intracardiac shunts, severe aortic-, tricuspid- or mitral stenosis or insufficiency and mechanical circulatory support were also excluded.

Design outcomes

Primary

MeasureTime frame
Accuracy of cardiac output in l/min by nine different pulse contour algorithms compared with transpulmonary thermodilutionAfter induction of anesthesia until the end of surgery

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 2, 2026