Skip to content

Safety Study of the PulseRider® in Patients Undergoing Treatment for Bifurcation Intracranial Aneurysms

Adjunctive Wide-neck Aneurysm Reconstruction Device Post Market Clinical Study Europe

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02435823
Acronym
AWARD
Enrollment
35
Registered
2015-05-06
Start date
2015-03-31
Completion date
2018-12-31
Last updated
2019-02-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Brain Aneurysm

Brief summary

This is a prospective multi-center, single arm, non-randomized study. It is designed to evaluate the safety of the PulseRider® in patients undergoing treatment for bifurcation intracranial aneurysms.

Detailed description

Primary Endpoints: Safety: Death or stroke in downstream territory to 180-days post-procedure Technical Success: Device placement success and ability to retain coils within the aneurysm (as judged by the treating physician at the time of the procedure. Core lab will review images at a later time) Rate of aneurysm occlusion at Day zero (0) and 180-days Additional Evaluations to 180-days and at 365-day follow up Rate of aneurysm occlusion at 365 days Device movement or migration defined as any relative change in the position of the device with respect to the parent and/or daughter vessels that is greater than 2mm by conventional catheter angiography, CTA or MRA (180 days) and (365 days) Stenosis defined as \>50% at implant site by conventional catheter angiography, MRA or CTA at 180 days and at 365 days Rate of incidence of new neurological deficits Complication rate (neurological and non-neurological)

Interventions

Adjunctive device for endovascular embolization of intracranial aneurysms

Sponsors

Pulsar Vascular
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patient who presents with an MRA, CTA or angiographically confirmed, wide neck (\> 4 mm or dome to neck ratio \< 2) intracranial aneurysms located at a bifurcation 2. The target aneurysm is in a vessel with a diameter of 2.7 mm to 4.5mm. 3. The patient is 18 years or older at the time of consent 4. The patient has signed the IRB/EC approved informed consent form 5. In the opinion of the physician, placement of the PulseRider is technically feasible and clinically indicated 6. Subject has mental capacity and is willing and able to comply with protocol requirements and follow-up

Exclusion criteria

1. Unstable neurological deficit (condition worsening within the last 90 days) 2. Subarachnoid Hemorrhage (SAH) within the last 60 days 3. Irreversible bleeding disorder 4. mRS score ≥3 5. Patient has another aneurysm which, in the Investigator's opinion, will require treatment within the follow up period (365 days) 6. Platelet count \< 100 x 103 cells/mm3or known platelet dysfunction 7. Inability to tolerate, adverse reaction or contraindication to taking aspirin or clopidogrel 8. A history of contrast allergy that cannot be medically controlled 9. Known allergy to nickel 10. Relative contraindication to angiography (e.g., serum creatinine \> 2.5 mg/dL) 11. Woman with child-bearing potential who cannot provide a negative pregnancy test 12. Evidence of active infection (fever with temperature \> 38°C and/or WBC \> 15,000) 13. Other conditions of the heart, blood, brain or intracranial vessels that carry a high risk of neurologic events 14. Evidence of disease or condition expected to compromise survival or ability to complete follow-up assessments during the 365-day follow-up period 15. Extracranial stenosis greater than 50% in the parent artery requiring access to the lesion 16. Intracranial stenosis greater than 50% in the treated vessel 17. Extreme vessel tortuosity that prohibits appropriate control of the micro-guide wire and/or the PulseRider delivery wire

Design outcomes

Primary

MeasureTime frameDescription
Safety: Death or stroke in downstream territoryto 180-days post-procedure
Technical Successat the time of the procedureDevice placement success and ability to retain coils within the aneurysm
Rate of aneurysm occlusionDay zero (within 24 hours post procedure) and 180-days

Secondary

MeasureTime frame
Rate of incidence of new neurological deficitsfrom the time of the procedure to the 365-follow up visit
Rate of aneurysm occlusionat 365-days follow-up
Complication rate (neurological and non-neurological)from the time of the procedure to the 365-follow up visit
Device movement or migration defined as any relative change in the position of the device with respect to the parent and/or daughter vessels that is greater than 2mm by conventional catheter angiography, MRA or CTAat 180-days follow-up and 365-days follow-up
Stenosis, defined as >50% at implant site by MR angiography or conventional catheter angiography or CTAat 180-days follow-up and 365-days follow-up

Countries

Austria

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026