CT of the Abdomen and Pelvis With Contrast Material
Conditions
Brief summary
1. To determine if a formula derived from PCA using specific patient parameters can be used to determine the individual contrast material dose and provide a more consistent level of vascular and parenchymal enhancement during MDCT scanning of the abdomen and pelvis. 2. Up to 500 adult patients referred for a CT of the abdomen and pelvis with contrast material will be recruited to participate in this trial. Single CT axial slices (n=2) will be obtained at the level of the L4 pedicle and the supra-acetabular pelvis using a field-of-view that includes all of the patient. From patient measurements (height, weight, body dimensions), a customized dose of contrast material will be specified according to the derived formula for 400 subjects. One hundred subjects will receive the usual fixed contrast dose. 3. Enhancement data in HU will be measured from the CT scans using manually-placed ROIs on the upper abdominal aorta, main portal vein and liver parenchyma, avoiding visible liver tumors, major blood vessels and artifacts, if present. This enhancement data will be used to determine the patient-to-patient variability.
Detailed description
The next step is a single center, prospective clinical trial intended to test the hypothesis that a formula derived from PCA using specific subject parameters can be used to determine the individual contrast material dose and provide a more consistent level of vascular and parenchymal enhancement during MDCT scanning of the abdomen and pelvis. 500 subjects referred for a CT of the abdomen and pelvis with contrast material will be recruited to participate in this trial. Subjects in the first group of 200 will be randomized to either a fixed dose of contrast material (100 subjects) or a customized dose of contrast material based on the experimental algorithm (100 subjects). The second group of 300 subjects will receive a customized dose of contrast material based on the experimental algorithm. All of the subjects will be studied on a single CT scanner located in the Duke Cancer Center. After obtaining informed consent, the subjects will first undergo measurement of their height and weight on a dedicated pair of scales located in close proximity to the scanner. The subjects will then be placed on the CT scan table in the supine position followed by the acquisition of scout digital radiographs in both the AP and ML projections. These digital scout radiographs are acquired routinely and used by the technologist to plan the scan. From these scout radiographs, single CT slices in the axial plane (n=2) will subsequently be obtained, one through the level of the L4 pedicle and the other through the supra-acetabular pelvis using a field-of-view that includes all of the subject. These slices are not part of the routine protocol but will be acquired using low radiation dose parameters. From these measurements (height, weight and specific body dimensions), a customized dose of contrast material will be specified according to the derived formula. Since the dose will be different in every subject, the rate will need to be adjusted as well. This will be accomplished by adjusting the rate so that the injection duration is the same in every subject. For example, if the specified contrast material dose is 100 mL and the injection duration is 25 seconds, the injection rate will be 4 mL/sec. If the specified contrast material dose is 125 mL and the injection duration is also 25 seconds, the injection rate will be increased to 5 mL/sec. Note that 100 subjects will receive a fixed dose and rate (150 mL of iopamidol with a concentration of 300 mg of iodine/mL at an injection rate of 3 mL/sec for a total dose of 45 grams of iodine) and 400 subjects will be administered a customized dose and rate (X mL of iopamidol with a concentration of 300 mg of iodine/mL at an injection rate of X mL/sec for a total dose of X grams of iodine) and. Also note that for the customized dose group, the maximum and minimum doses of contrast material will be 200 (75 gm iodine) and 75 (22.5 gm iodine) mL, respectively and the maximum and minimum injection rates will be 6 and 2 mL/sec, respectively. Because the injection rate in the customized group is variable, the nurse or technologist establishing intravenous access may choose to use a larger or small caliber angiocatheter than in the fixed group in order to accommodate a higher or lower injection rate, respectively. The caliber of the angiocatheter as well as the venous access site will be recorded along with the dose and rate of contrast material. The rate of administration of contrast material is controlled by a mechanical power injector furnished by Nemoto Kyorindo Co, Ltd. free of charge for use in this study.
Interventions
Iopamidol is the contrast material being used for this study. 100 subjects will receive a fixed dose and rate (150 mL of iopamidol with a concentration of 300 mg of iodine/mL at an injection rate of 3 mL/sec for a total dose of 45 grams of iodine) and 400 subjects will be administered a customized dose and rate (X mL of iopamidol with a concentration of 300 mg of iodine/mL at an injection rate of X mL/sec for a total dose of X grams of iodine).
400 subjects will receive a customized dose of contrast material (iopamidol) based on the experimental algorithm Mydose using a combination of subject parameters.
Sponsors
Study design
Eligibility
Inclusion criteria
* Patients referred for a CT of the Abdomen & Pelvis with Contrast Material
Exclusion criteria
* Younger than 18 * Pregnant * Contraindication of iodinated contrast material * Contraindication to a bolus injection * Indication for biphasic exam (arterial + venous phases) * Diffuse hepatic disease * Subjects weighing more than 300 pounds
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Variability in Enhancement Data, Measured in Hounsfield Units (HU) | During CT scan, approximately 5 minutes |
Countries
United States
Participant flow
Pre-assignment details
A total of 10 enrolled subjects either screen failed or were withdrawn by the PI prior to randomization. Four subjects screen failed due to changes in their clinical orders prior to imaging. Six subjects were withdrawn by the PI due to patient scheduling conflicts.
Participants by arm
| Arm | Count |
|---|---|
| Fixed Dose 100 of the first 200 subjects will be randomized to a fixed dose of contrast material.
Iopamidol: Iopamidol is the contrast material being used for this study. 100 subjects will receive a fixed dose and rate (150 mL of iopamidol with a concentration of 300 mg of iodine/mL at an injection rate of 3 mL/sec for a total dose of 45 grams of iodine) and 400 subjects will be administered a customized dose and rate (X mL of iopamidol with a concentration of 300 mg of iodine/mL at an injection rate of X mL/sec for a total dose of X grams of iodine). | 77 |
| Customized Dose 100 of the first 200 subjects will be randomized to a customized dose of contrast material based on the experimental algorithm. The second group of 300 subjects will receive a customized dose of contrast material based on the experimental algorithm.
Iopamidol: Iopamidol is the contrast material being used for this study. 100 subjects will receive a fixed dose and rate (150 mL of iopamidol with a concentration of 300 mg of iodine/mL at an injection rate of 3 mL/sec for a total dose of 45 grams of iodine) and 400 subjects will be administered a customized dose and rate (X mL of iopamidol with a concentration of 300 mg of iodine/mL at an injection rate of X mL/sec for a total dose of X grams of iodine).
Mydose: 400 subjects will receive a customized dose of contrast material (iopamidol) based on the experimental algorithm Mydose using a combination of subject parameters. | 79 |
| Total | 156 |
Baseline characteristics
| Characteristic | Customized Dose | Total | Fixed Dose |
|---|---|---|---|
| Age, Continuous | 61.7 years STANDARD_DEVIATION 12 | 62.4 years STANDARD_DEVIATION 12.8 | 63.2 years STANDARD_DEVIATION 13.6 |
| Ethnicity (NIH/OMB) Hispanic or Latino | 0 Participants | 1 Participants | 1 Participants |
| Ethnicity (NIH/OMB) Not Hispanic or Latino | 79 Participants | 154 Participants | 75 Participants |
| Ethnicity (NIH/OMB) Unknown or Not Reported | 0 Participants | 1 Participants | 1 Participants |
| Race (NIH/OMB) American Indian or Alaska Native | 1 Participants | 1 Participants | 0 Participants |
| Race (NIH/OMB) Asian | 0 Participants | 1 Participants | 1 Participants |
| Race (NIH/OMB) Black or African American | 13 Participants | 23 Participants | 10 Participants |
| Race (NIH/OMB) More than one race | 0 Participants | 0 Participants | 0 Participants |
| Race (NIH/OMB) Native Hawaiian or Other Pacific Islander | 0 Participants | 0 Participants | 0 Participants |
| Race (NIH/OMB) Unknown or Not Reported | 0 Participants | 1 Participants | 1 Participants |
| Race (NIH/OMB) White | 65 Participants | 130 Participants | 65 Participants |
| Sex: Female, Male Female | 30 Participants | 62 Participants | 32 Participants |
| Sex: Female, Male Male | 49 Participants | 94 Participants | 45 Participants |
Adverse events
| Event type | EG000 affected / at risk | EG001 affected / at risk |
|---|---|---|
| deaths Total, all-cause mortality | 0 / 77 | 0 / 79 |
| other Total, other adverse events | 0 / 77 | 0 / 79 |
| serious Total, serious adverse events | 0 / 77 | 0 / 79 |
Outcome results
Variability in Enhancement Data, Measured in Hounsfield Units (HU)
Time frame: During CT scan, approximately 5 minutes
| Arm | Measure | Value (MEAN) | Dispersion |
|---|---|---|---|
| Fixed Dose | Variability in Enhancement Data, Measured in Hounsfield Units (HU) | 199 Hounsfield Units (HU) | Standard Deviation 45 |
| Customized Dose | Variability in Enhancement Data, Measured in Hounsfield Units (HU) | 205 Hounsfield Units (HU) | Standard Deviation 50 |