Skip to content

A Randomized Controlled Open Label Trial to Assess the Safety and Efficacy of the OptiVein IV Catheter in an Oncologic Population

A Randomized Controlled Open Label Trial to Assess the Safety and Efficacy of the OptiVein IV Catheter in an Oncologic Population

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02420028
Enrollment
109
Registered
2015-04-17
Start date
2015-04-02
Completion date
2016-08-05
Last updated
2018-09-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intravenous Injections

Brief summary

A prospective, single-center, open-label, randomized controlled trial to assess the safety and efficacy of the OptiVein IV Catheter in an oncology population. The study hypothesis is that OptiVein IV Catheter use will be superior to the control in successful venous access after first attempt.

Detailed description

The OptiVein IV Catheter is a sterile single use disposable intravascular cannulation device that is modified from CE certified Vasofix Certo Catheter from B.Braun with the additional features of an optical fiber and modified flashplug. The OptiVein System also includes an electronic unit. The study control and predicate device is the Vasofix Certo IV Catheter from B. Braun Medical Inc. This device is the base device for the OptiVein IV Catheter to which is added the optical fiber and electronic unit. The OptiVein Catheter shares a similar intended use and the same catheter components as the Vasofix Certo IV Catheter. Clinical data will be obtained to assess if there is a change to the safety and efficacy profile due to the laser component of the OptiVein IV Catheter. Subject population consists of Oncologic patients who have either difficult to access veins or who have experienced an unsuccessful IV start during their previous visit to the hospital, requiring short-term use of an IV catheter to administer chemotherapy medications intravenously. Subjects may be enrolled multiple times, with each patient-visit being the unit of analysis. Primary efficacy endpoint is successful IV insertion on the first attempt, defined as placement of the catheter inside the vein allowing for fluid or drug delivery or blood withdrawal. 167 and 167 patient-visits will be included in OptiVein or Vasofix Certo respectively (1:1 randomization), resulting in a total sample size of 334 visits. This sample size will provide 80% power to demonstrate the superiority of the OptiVein Catheter to the Vasifix Certo Catheter. Secondary endpoints include: 1. Total number of attempts required for successful IV insertion. 2. Time to successful IV insertion, defined as time from the first skin puncture to placement of the catheter inside the vein allowing for fluid or drug delivery or blood withdrawal 3. Incidence of blood extravasation resulting in a hematoma 4. Incidence of fluid extravasation delivered through catheter 5. Incidence of infection (phlebitis, dermatitis and induration) at insertion site through 72 hours or at the time of catheter removal, whichever occurs first. 6. Unplanned withdrawal of IV catheter 7. Overall complication rate composed from #3-6 above

Interventions

DEVICEInsertion of OptiVein IV catheter

Placement of OptiVein IV catheter inside the vein allowing for fluid or drug delivery or blood withdrawal.

DEVICEInsertion of Vasofix Certo IV catheter

Placement of Vasofix Certo IV catheter inside the vein allowing for fluid or drug delivery or blood withdrawal.

Sponsors

CardioMed Device Consultants, LLC
CollaboratorINDUSTRY
Optomeditech Oy
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SUPPORTIVE_CARE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patients on an ongoing chemotherapy program thru peripheral veins delivery 2. Has difficult to access veins (class II or III) OR has experienced an unsuccessful IV start during his/her previous visit to the hospital 3. Requires peripheral IV therapy (catheter) 4. Has an insertion site in the forearm or hand free of deformities, phlebitis, infiltration, dermatitis, burns, lesions or tattoos 5. Demonstrates cooperation with a catheter insertion and the study protocol 6. Patients 18 years of age or greater

Exclusion criteria

1. Patients receiving pre-warming of the insertion site 2. Is anesthetized 3. Has a life expectancy of less than one month 4. Transferred from the operating room less than 8 hours post-anasthesia 5. Any patient the research staff deem unobservable 6. The study IV site needs to be immobilized with a splint or other devices 7. Will require a power injection for a radiologic procedure during participation in this study

Design outcomes

Primary

MeasureTime frameDescription
Successful IV insertion on the first attemptImmediateSuccessful placement of the catheter inside the vein allowing for fluid or drug delivery or blood withdrawal.

Secondary

MeasureTime frameDescription
Time to successful IV insertionImmediateDefined as time from the first skin puncture to placement of the catheter inside the vein allowing for fluid or drug delivery or blood withdrawal
Incidence of blood extravasation resulting in a hematomaImmediate
Total number of attempts required for successful IV insertionImmediate
Incidence of infectionAfter 72 hours or release from hospital, whichever occurs first.phlebitis, dermatitis and induration at insertion site through 72 hours or at the time of catheter removal, whichever occurs first.
Unplanned withdrawal of IV catheterImmediate
Incidence of fluid extravasation delivered through catheterImmediate

Countries

Finland

Outcome results

None listed