Skip to content

Closed-loop Control of Postprandial Glucose Levels in Adults With Type 1 Diabetes

An Open-label, Randomized, Five-way, Cross-over Study to Compare the Efficacy of Single- and Dual-hormone Closed-loop Operations Combined With Either Conventional Carbohydrate Counting or a Simplified Qualitative Meal-size Estimation, and Sensor-augmented Pump Therapy in Regulating Glucose Levels in Adults With Type 1 Diabetes

Status
Completed
Phases
Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02416765
Enrollment
15
Registered
2015-04-15
Start date
2015-05-31
Completion date
2015-10-31
Last updated
2015-11-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Type 1 Diabetes

Keywords

Closed-loop strategy, Artificial pancreas, Postprandial glucose, Insulin, Glucagon, Hypoglycemia, Type 1 diabetes

Brief summary

Postprandial meal glucose control with closed-loop systems (CLS) still needs some improvements. In the postprandial period, sensor delay in detecting blood glucose rise after a meal together with delays in insulin absorption expose patients to early risk of hyperglycemia and then to late-postprandial hypoglycemia. Glucagon infusion in dual-hormone CLS has the potential to improve post-meal control as compared to single-hormone CLS allowing a better glucose excursion related to a more aggressive insulin infusion while minimizing hypoglycemic risk. Several approaches have been tested for the determination of prandial boluses during closed-loop operation. The objective of this study is to test in outpatient unrestricted settings whether, in the context of closed-loop strategy, conventional meal carbohydrate counting could be reduced to a simplified qualitative meal size estimation without a significant degradation in overall glycemic control in adult patients with type 1 diabetes. The investigators hypothesize that in outpatient free-living conditions: 1) Dual-hormone CLS with partial boluses is equivalent to dual-hormone CLS with full boluses in terms of mean glucose; 2) Single-hormone CLS with partial boluses is equivalent to single-hormone CLS with full boluses in terms of mean glucose. Secondary hypothesis are: 3) Dual-hormone CLS with partial boluses will decrease time in hypoglycemia compared to single-hormone CLS with partial boluses; 4) Dual-hormone CLS with partial boluses is better than sensor-augmented pump therapy in terms of mean glucose; 5) Single-hormone CLS with partial boluses is better than sensor-augmented pump therapy in terms of mean glucose.

Interventions

OTHER15-hour intervention

Interventions will be conducted in outpatient settings. Subject's usual insulin will be used. Meals will not be standardized. Subjects will be allowed to eat whatever and when they want and will be allowed to drink alcohol. Subjects will be allowed to exercise, but they will be asked to do the same amount and intensity of exercise on all intervention visits. Subjects will be accompanied all the time by a member from the research team during closed-loop visits to implement hormonal infusions.

DRUGInsulin (Lispro, Aspart or guilisine)

Patient's usual insulin (Lispro, Aspart or guilisine) will be used in all interventions.

DRUGGlucagon (Eli Lilly)

In the dual-hormone CLS interventions, glucagon (Eli Lilly) will be used.

OTHERClosed-loop strategy

Every 10 minutes, the glucose level as measured by the real time sensor (Dexcom G4 Platinum, Dexcom) will be entered manually into the computer. The pumps' infusion rate will then be changed manually based on the computer generated recommendation infusion rates. The computer generated recommendations are based on a predictive algorithm.

Sponsors

Institut de Recherches Cliniques de Montreal
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Males and females ≥ 18 years old. 2. Clinical diagnosis of type 1 diabetes for at least one year. 3. The subject will have been on insulin pump therapy for at least 3 months and currently using a fast actin insulin analog (Lispro, Aspart or Guilisine). 4. Last (less than 3 months) HbA1c ≤ 10%. 5. Currently using carbohydrate counting as the meal insulin dose strategy.

Exclusion criteria

1. Clinically significant microvascular complications: nephropathy (estimated glomerular filtration rate below 40 ml/min), neuropathy (especially diagnosed gastroparesis) or severe proliferative retinopathy as judged by the investigator. 2. Recent (\< 3 months) acute macrovascular event e.g. acute coronary syndrome or cardiac surgery. 3. Ongoing pregnancy. 4. Severe hypoglycemic episode within 1 month of screening. 5. Agents affecting gastric emptying (Motilium®, Prandase®, Victoza®, Byetta® and Symlin®) as well as oral anti-diabetic agents (Metformin, SGLT-2 inhibitors and DPP-4 inhibitors) if not at a stable dose for 3 months. Otherwise, these medications are acceptable and will be kept stable during the entire protocol. 6. Oral steroids unless patients present a low stable dose (e.g. 10 mg or less of prednisone per day or physiological doses, less than 35 mg/day, of hydrocortisone Cortef®). Inhale steroids at stable dose in the last month are acceptable. 7. Other serious medical illness likely to interfere with study participation or with the ability to complete the trial by the judgment of the investigator (e.g. unstable psychiatric condition). 8. Failure to comply with team's recommendations (e.g. not willing to change pump parameters, follow algorithm's suggestions, etc). 9. Living or planned travel outside Montreal (\> 1h of driving) area during closed-loop procedures.

Design outcomes

Primary

MeasureTime frameDescription
Mean glucose levels as measured by the glucose sensor.15 hoursThe following comparisons will be done: 1) Dual-hormone CLS with partial boluses vs. dual-hormone CLS with full boluses; 2) Single-hormone CLS with partial boluses vs. single-hormone CLS with full boluses.

Secondary

MeasureTime frameDescription
Mean glucose levels as measured by the glucose sensor15 hoursThe following comparisons will be done: 1) Dual-hormone CLS with partial boluses vs. single-hormone CLS with partial boluses; 2) Dual-hormone CLS with partial boluses vs. sensor-augmented pump therapy; 3) Single-hormone CLS with partial boluses vs. sensor-augmented pump therapy.
Percentage of time of sensor glucose concentrations between 4 and 8 mmol/L15 hours
Percentage of time of sensor glucose concentrations between 4 and 10 mmol/L15 hours
Percentage of time of sensor glucose concentrations above 10 mmol/L15 hours
Percentage of time of sensor glucose concentrations above 14 mmol/L15 hours
Percentage of time of glucose levels spent below 4 mmol/L15 hours
Percentage of time of glucose levels spent below 3.1 mmol/L15 hours
Total glucagon delivery15 hours
Area under the curve of glucose values below 3.1 mmol/L15 hours
Number of patients with at least one hypoglycemic event below 3.1 mmol/L with or without symptoms15 hours
Total number of hypoglycemic event below 3.1 mmol/L15 hours
Total insulin delivery15 hours
Standard deviation of glucose levels15 hours
Total carbohydrate intake15 hours
Area under the curve of glucose values below 4 mmol/L15 hours

Countries

Canada

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026