Skip to content

Investigation of Diagnostic Improvement Gained Through Optimization of MR Methods for Breast Cancer Detection

Investigation of Diagnostic Improvement Gained Through Optimization of MR Methods for Breast Cancer Detection

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02411760
Acronym
BCD
Enrollment
60
Registered
2015-04-08
Start date
2014-05-31
Completion date
2017-05-31
Last updated
2017-10-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Breast Neoplasms

Keywords

MRI

Brief summary

In a single MRI exam on a research scanner, each lesion will be categorized using the BI-RADS MRI score, which utilizes the DCE data alone, and then again using a modified BI-RADS score, which utilizes both DWI and DCE data. The sensitivity and specificity of each approach will be determined using pathology as the gold standard.

Detailed description

MR examinations will be performed on a 3.0 Tesla GE whole-body scanner using an elliptically driven body coil for transmit and a multi-channel bilateral breast coil for receive. The multi-channel coil will consist of 8, 16 or 31 channels. DCE-MRI: DCE-MRI will be carried out using a three-dimensional (3D) turbo fast lowangle gradient echo sequence (TFE) combined with parallel acquisition Sensitivity Encoding (SENSE) technique. The imaging plane will be set in axial plane so that both breasts are included in the images. One image will be acquired before and four images will be acquired after intravenous administration of a standard dose of 0.1 mmol per kg of body weight of Gadavist (Schering AG, Germany) at a rate of 3ml/sec. with subjects in the prone position, breathing normally during the scan. The total scan time for the DCEMRI will be about 8 minutes. Pharmacokinetic parameters, including the volume transfer constant Ktrans, the fractional volume of extravascular extracellular space of the target tissue ve, and the rate constant kep, will be estimated by fitting a pharmacokinetic model to the time-intensity curves obtained from the DCE-MRI. In this study, the concentration of tracer Ct(t) after bolus injection is assumed to obey the model proposed by Tofts and Kermode (20). DWI-MRI examinations: The DWI acquisition will occur before and/or after contrast enhancement used in DCE imaging. Immediately after the completion of imaging with the 16 (or 31) channel breast coil, the patient will be repositioned replacing the breast coil with an 8 channel breast coil and additional DWI acquisitions will be made. Data for apparent diffusion coefficient assessment on diffusion-weighted imaging will be acquired using a single-shot Echo Planar Imaging sequence in the transverse plane. The DWI protocol will acquire images with up to 16 different b values. Slice dependent shimming will be performed to provide the maximum B0 homogeneity for each slice. The total scan time for the DWI-MRI will be about 5 minutes. All of the DWI image data from the MRI examinations will be stored on a dedicated HIPPA compliant computer workstation (located in room NE6.114) for analysis. The relevant parameters will be mean ADC and the histogram of ADC in the lesions. Conductivity imaging: A B1 map and a spin echo image will be acquired for measuring tissue conductivity (21). The images used for conductivity measurement will be anonymized and sent to the manufacturer for further development of post-processing techniques.

Interventions

Assessment of the performance of DWI/ADC measurements alone, and as an adjunct to dynamic contrast enhanced (DCE) MRI in diagnosing/characterizing breast cancer.

Sponsors

University of Texas Southwestern Medical Center
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Women with Breast Imaging-Reporting and Data System (BI-RADS) 4 or 5 Age ≥ 18 years Ability to understand and the willingness to sign a written informed consent.

Exclusion criteria

Subjects who have had a needle biopsy of the suspicious area within the last 6 weeks Subjects who have contraindication to contrast enhanced MRI examination. Contraindications to MRI examinations include: Medically unstable * Heart failure * Unstable angina * Child bearing * Lactating Any contraindication per MRI Screening Form (Appendix A attached). * Implants contraindicated at 3T, pacemakers * Poorly controlled diabetes * Body weight greater than 300 pounds * Claustrophobic Since each patient is receiving a gadolinium based contrast agent intravenously: * eGFR \< 60 mL/min/1.73m2 * Sickle cell disease * Hemolytic anemia Subjects must not be pregnant or nursing due to the potential for gadolinium contrast agents to harm fetuses or nursing infants.

Design outcomes

Primary

MeasureTime frameDescription
Diagnostic Improvement Gained using an optimized MR Method for Breast Cancer Detection.Each of 60 patients will have 1 60 minute scan prior to biopsyThe sensitivity and specificity of breast cancer detection using ADC maps acquired with a 31 channel breast coil and improved B0 shimming will be compared to the sensitivity and specificity of cancer detection using DCE MRI.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026