Skip to content

An Assessment of the Glider Balloon in Complex Lesions

An Assessment of the Glider Balloon in Complex Lesions

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02396186
Acronym
ANTELOPE
Enrollment
100
Registered
2015-03-24
Start date
2015-03-31
Completion date
2017-06-30
Last updated
2018-09-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Brief summary

The purpose of this study is to collect data from real-world use with the Glider Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Catheter to support the effectiveness of the Glider PTCA Balloon for crossing into complex coronary lesions.

Detailed description

Observational Study collecting data on commercial cases in which the Glider PTCA Balloon Catheter is used in accordance with the instructions for use. This study includes up 500 patients at up to 50 study sites.

Interventions

DEVICEPTCA Balloon Angioplasty

Sponsors

TriReme Medical, LLC
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Lesion must be successfully crossed with a guidewire without complication (including Chronic Total Occlusions (CTOs)) 2. The Glider balloon may only be used at one lesion during the procedure 3. The lesion in which the Glider balloon is used must be completed first 4. The primary lesion treated during the procedure must be treated with the Glider balloon 5. Intended treatment of a protocol-defined complex lesion that has at least one of the following factors: * Significant vessel tortuosity * Failed balloon crossing with another balloon * Tight stenosis * Heavy calcification * Side branch present

Exclusion criteria

1. Patient \< 18 years of age 2. Lesion longer than 40mm 3. Device use not consistent with Instructions for Use 4. Patient has not given consent for their data to be submitted to this registry

Design outcomes

Primary

MeasureTime frameDescription
Technical Success Rate1 hourPercentage of lesions successfully crossed among those attempted with the Glider PTCA catheter.

Secondary

MeasureTime frameDescription
Freedom from Balloon Slippage1 hourPercentage of inflations with the Glider balloon in which the physician user reports no slippage.
Lesion Success Rate48 hoursPercentage of lesions with \<50% diameter stenosis, or Thrombolysis In Myocardial Infarction (TIMI) 3 flow if side branch is present, without development of MACE during hospital stay.

Countries

United States

Outcome results

None listed