Radio Frequency Ablation for Atrial Flutter With Magnetic Resonance Guidance and Tracking

Radio Frequency Ablation for Atrial Flutter With Magnetic Resonance Guidance and Tracking: Pilot Study Using a Combination Imricor and Philips Interventional System

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02380937
Enrollment
8
Registered
2015-03-05
Start date
2015-01-31
Completion date
2015-08-31
Last updated
2018-02-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Flutter

Keywords

real-time MRI, electrophysiology study, atrial flutter, ablation, active tracking

Brief summary

The Radio Frequency Ablation for Atrial Flutter with Magnetic Resonance Guidance and Tracking Pilot Study (hereafter referred to as pilot study) is a prospective, non- randomized, single-center, pilot study. The purpose of this clinical study is to evaluate the safety and performance of the Imricor Medical Systems, Inc. (Imricor) Vision Ablation Catheter when used with related accessories for the treatment of type I atrial flutter. The Vision Ablation Catheter and its accessories have been designed for use under fluoroscopic or magnetic resonance guidance.

Detailed description

An objective of the study is to perform the entire ablation procedure from subject preparation through confirmation of bidirectional conduction block entirely under magnetic resonance guidance. However, at the investigator's discretion, the preparation of the subject may occur in a conventional electrophysiology laboratory followed by transferring the patient to the magnetic resonance suite for the ablation procedure. Additionally, if bidirectional conduction block is not achieved within 90 minutes from the initial catheter placement, the subject may be transferred from the magnetic resonance suite to a conventional electrophysiology lab to complete the procedure. Clinical success is bidirectional conduction block regardless of the environment within which the ablation occurs. The study will be conducted at a single center, Herzzentrum Leipzig University Hospital, in Germany, and a maximum of 30 subjects meeting inclusion/exclusion criteria will participate in the study. This study requires the use of investigational products from two independent manufacturers: Imricor and Philips. Imricor has developed the ablation catheter with related accessories, introducers, and recording system. Philips has developed an image guidance and mapping system that is compatible with the Imricor products. The Vision Ablation Catheter will be used in conjunction with the following investigational products: Vision Ablation Catheter Cable Set (accessory sterile cable), Vision Hemostasis Introducer, Vision Dual-Deflect Sheath, Horizon recording system, and the interventional MRI Suite (iSuite) image guidance and mapping system. With the exception of iSuite, which is manufactured by Philips, Imricor will provide all investigational devices used in the study. Each procedure will utilize the following two single-use products: two Vision Ablation Catheters and an accessory Catheter Cable set. At the discretion of the investigator, Vision Hemostasis Introducers may be used for femoral access and a Vision Dual- Deflect Sheath and may be used in conjunction with the Vision Ablation Catheter Cable Set. Ablation for the treatment of arrhythmia is an inherently complex procedure. Use of the investigational products listed above under magnetic resonance guidance is a new approach to performing the interventional electrophysiology procedure. The study population will consist of adult patients requiring ablation for type I atrial flutter. Study subjects will require a follow-up visit or telephone call at 7 days post procedure. Accordingly, the expected total study duration is approximately six months with study start planned for October 2014.

Interventions

ablation for typical atrial flutter

DEVICEVision Ablation Catheter

Sponsors

Heart Center Leipzig - University Hospital
CollaboratorOTHER
Philips Healthcare
CollaboratorINDUSTRY
Imricor Medical Systems
CollaboratorINDUSTRY
University of Leipzig
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* First time indication for type I atrial flutter ablation * Age 18 or above * Patients willing and able (mentally and physically capable per physician's discretion) to understand the investigational nature, potential risks and benefits of the study and able to provide written informed consent to participate in the study and agree to comply with follow-up visits and evaluation * Patients able to receive anticoagulation therapy to achieve adequate anticoagulation

Exclusion criteria

* Contraindication for MRI diagnostic exam * A cardiac ablation or cardiac surgery within 90 days prior to enrollment * Documented intracardiac thrombus, tumor, bleeding, clotting or other abnormality that precludes catheter introduction and placement * Myocardial infarction within 60 days prior to enrollment * Current unstable angina * History of cerebrovascular event (within 180 days prior to enrollment) * Patients with an ejection fraction less than or equal to 30% within 90 day prior to enrollment * Permanent leads in or through the right atrium * Clinically significant structural heart disease (including tricuspid valve regurgitation, tricuspid valve stenosis or other congenital heart disease) that would preclude catheter introduction and placement, as determined by the Investigator * Uncompensated congestive heart failure (NYHA Class III or IV) * Arrhythmia is secondary to electrolyte imbalance, thyroid disease, or other * reversible or non-cardiovascular cause * Known sensitivity to heparin or warfarin * Active or systemic infection * Any other significant uncontrolled or unstable medical condition (including but not limited to hypertension and diabetes) * Women who are pregnant or plan to become pregnant within the course of their participation in the investigation or who are breastfeeding * Life expectancy of less than 12 months * Patients with prosthetic valves * Contraindicated for transfemoral venous access * Older than 75 years * Current enrollment in any other clinical investigation

Design outcomes

Primary

MeasureTime frameDescription
Number of serious adverse events1 dayTo provide scientific evidence that the Vision Ablation Catheter is safe as measured by the incidence of device and procedure related serious adverse events (SAEs).

Secondary

MeasureTime frame
Number of participants with successful ablation7 days

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026