Skip to content

Post Market Clinical Follow Up of LEGION™ Primary TKS With VERILAST™

A Multicentre, Prospective, Post Market Clinical Follow Up Study of the LEGION™ Primary Total Knee System With VERILAST™ Bearing Surface

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02380092
Enrollment
163
Registered
2015-03-05
Start date
2015-09-30
Completion date
2029-05-31
Last updated
2025-12-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Degenerative Joint Disease

Keywords

Knee, Post-Market Surveillance, Legion, Verilast, Degenerative Joint Disease

Brief summary

LEGION™ Primary Total Knee System is CE-marked and marketed in all study regions. This study serves as post-market surveillance for LEGION™ Primary Total Knee System with the VERILAST™ bearing surface (OXINIUM™ femoral component with highly cross-linked polyethylene tibial insert). All study subjects will receive a LEGION™ Primary Total Knee System with VERILAST™ bearing surface and the results will be analysed against historical data from patients who received a Genesis II knee replacement.

Detailed description

The LEGION™ Primary Total Knee System (TKS) is a comprehensive, state-of-the-art system that empowers surgeons to address diverse surgical challenges and provide personalized joint care. The LEGION™ Primary TKS implant designs were built on the legacy of the GENESIS™ II TKS. For more than 15 years and in more than 30 countries, the GENESIS™ II TKS has achieved outstanding clinical outcomes. As CE-mark and 510k approval for the LEGION™ Primary TKS has been obtained, it is being used in clinical practice in several countries including Europe and the US but clinical studies need to be carried out in order to confirm its safety and efficacy and in order to conform to the medical device directives (MEDDEV. 2.7.1 Rev.3). This study is therefore a post-market study to evaluate the short-, mid- and long-term safety and effectiveness of the LEGION™ Primary TKS with VERILAST™ bearing surface (the combination of an OXINIUM™ femoral component with highly cross-linked polyethylene tibial base plate inserts). The clinical outcome from a large cohort of subjects who are treated with the LEGION™ Primary TKS as part of their standard of care will be documented. The study is designed to reflect standard clinical practice as closely as possible because it allows the results of such a study to represent the true clinical outcome that would be achieved in clinical practice, up to a maximum. Only subjects who will be treated with the LEGION™ Primary TKS as part of their normally planned care will screened for participation in this study.

Interventions

DEVICELEGION™ Primary TKS with VERILAST™ Bearing Surface

All study subjects will be treated with LEGION™ Primary TKS with VERILAST™ Bearing Surface as per standard clinical practice.

Sponsors

Smith & Nephew, Inc.
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* Subject requires primary TKA and has elected to use the LEGION™ Primary TKS with VERILAST™. * Subject requires primary TKA due to degenerative joint disease (primary osteoarthritis, post-traumatic arthritis, avascular necrosis, rheumatoid arthritis). * Subject is of legal age to consent, agrees to consent to and to follow the study visit schedule (as defined in the study protocol and informed consent form), by signing the EC approved informed consent form. * Routine radiographic assessment is possible. * Subject plans to be available through ten (10) years postoperative follow-up. * Subject is 18-75 years of age at the time of surgery.

Exclusion criteria

* Age \> 75 years at the time of surgery. * Subjects with immunosuppressive disorders. * Subject has severe pronation of the ipsilateral foot or any other relevant clinical condition contributing to abnormal ambulation (including but not limited to ankle fusion, ankle arthroplasty, previous hip fracture, ipsilateral hip arthritis resulting in flexion contracture). * Subject has undergone a previous major surgery to the study knee (including osteotomy, fracture fix, medial or lateral ligament surgery). * Subject has active infection or sepsis (treated or untreated). * At the time of enrollment, subject has one or more of the following arthroplasties that are not fully healed and well-functioning, as determined by the Investigator: * Ipsilateral or contralateral primary total hip arthroplasty or hip resurfacing arthroplasty. * Contralateral primary total knee or unicondylar knee arthroplasty. * Subject has presence of malignant tumor, metastatic, or neoplastic disease. * Subject has conditions that may interfere with the TKA survival or outcome (i.e., Paget's or Charcot's disease, muscular atrophy, uncontrolled diabetes, moderate to severe renal insufficiency or neuromuscular disease). * Subject has any acute or chronic morbidity of vascular origin that, in the opinion of the Investigator, is likely to compromise successful treatment or compliance to follow-up visits. * Subject has inadequate bone stock to support the device (severe osteopenia, family history of severe osteoporosis or osteopenia). * Subject has an emotional or neurological condition that would pre-empt their ability or willingness to participate in the study. * Subject has a Body Mass Index (BMI) \>40.0. * Subject requires revision TKA. * Subject is expected to require bilateral TKA within 1 year following study knee replacement. * Subject does not understand the language used in the Informed Consent Form. * Subject is enrolled in another clinical study at the same time.

Design outcomes

Primary

MeasureTime frameDescription
Survival10 yearsNon-inferiority of survival of Legion Primary with Verilast compared to a literature reference rate of 92.6% for Genesis II TKS

Secondary

MeasureTime frameDescription
Number of revisionsDischarge, 3 months, 1 year, 3 years, 5 years, 7 years, 10 yearsNumber of revisions (of any component of the device) at all follow up timepoints
Changes in mean 2011 Knee Society ScoreDischarge, 3 months, 1 year, 3 years, 5 years, 10 yearsChanges in mean 2011 Knee Society Score from baseline to each subsequent assessment
Changes in mean Euroqol 5-D scoreDischarge, 3 months, 1 year, 3 years, 5 years, 10 yearsChanges in mean Euroqol 5-D score from baseline to each subsequent assessment
Changes in radiographic evaluationDischarge, 3 months, 1 year, 3 years, 5 years, 10 yearsChanges in radiographic evaluation from baseline to each subsequent assessment
AEsOperative, Discharge, 3 months, 1 year, 3 years, 5 years, 7 years, 10 yearsAdverse Event reporting from surgery to 10 years post surgery

Countries

Austria, Germany, Spain

Outcome results

None listed