Effect of the Height of the Operating Table During Spinal Anesthesia

Effect of the Height of the Operating Table During Spinal Anesthesia

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02373410
Enrollment
60
Registered
2015-02-27
Start date
2014-09-30
Completion date
2015-08-31
Last updated
2015-02-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anesthesia, Spinal [E03.155.086.331], Operating Tables [E07.325.662]

Brief summary

The purpose of this study is to analyze the accuracy of needle insertion and the discomfort during different ergonomic conditions faced by anesthesiologists during spinal anesthesia. In particular,the investigators intend to compare the angles between the patients' back and the inserted spinal needle in the coronal plane at different operating table heights.

Detailed description

Sixty patients will be recruited undergoing elective surgery under spinal anesthesia. The patients will be randomly allocated to one of four groups: Group U, L, X, and N. These acronyms indicate the heights of the operating table which set at the needle insertion point of anesthetists, namely the level of umbilicus, lowest rib margin, xiphoid process, and nipple in a standing posture. The angle between the patient's skin and the spinal needle will be measured by the protractor in the coronal and sagittal plane. The anesthesiologists will be asked to record the subjective general discomfort graded by Numeric Rating Scale. And the degree of neck, lower back, knee, and elbow flexion of the anesthesiologists will be measured by taking pictures during procedure.

Interventions

PROCEDUREUmbilicus

Depending on the height of the operating table, the insertion angle of the spinal needles would be vary. The investigators intend to find the optimal angle and the height of the table to provide that. The height of the operating table which set at the needle insertion point of anesthetists; the level of umbilicus

PROCEDURELowest rib margin

The height of the operating table which set at the needle insertion point of anesthetists; the level of lowest rib margin

PROCEDUREXiphoid

The height of the operating table which set at the needle insertion point of anesthetists; the level of xiphoid

PROCEDURENipple

The height of the operating table which set at the needle insertion point of anesthetists; the level of nipple

DRUGUmbilicus Bupivacaine

If freely flowing of CSF is detected, appropriate dose of MARCAINE was injected in all interventional groups.

DRUGLowest rib margin Bupivacaine

If freely flowing of CSF is detected, appropriate dose of MARCAINE was injected in all interventional groups.

DRUGXiphoid Bupivacaine

If freely flowing of CSF is detected, appropriate dose of MARCAINE was injected in all interventional groups.

DRUGNipple Bupivacaine

If freely flowing of CSF is detected, appropriate dose of MARCAINE was injected in all interventional groups.

Sponsors

Seoul National University Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Caregiver)

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* undergoing elective surgery under spinal anesthesia

Exclusion criteria

* body mass index (BMI)\>30 * history of spine operation or severe anatomical abnormalities of spine

Design outcomes

Primary

MeasureTime frame
The angle between the patient's skin and the spinal needleduring procedure

Secondary

MeasureTime frame
anesthesiologist's subjective discomfortduring procedure
the degree of anesthesiologist's joint flexionduring procedure

Countries

South Korea

Contacts

Primary ContactJinhee Kim, MD,PhD
shm@snubh.org82-31-787-7505
Backup ContactHyerim Kim, MD
kimhl911@daum.net82-10-7120-9110