Mitral Implantation of TRAnscatheter vaLves

The Safety and Feasibility of the SAPIEN XTTM Transcatheter Heart Valve With NovaFlex and Ascendra Delivery Systems and SAPIEN 3 With Commander Delivery System in Patients With Symptomatic Severe Calcific Mitral Valve Disease With Severe Mitral Annular Calcification and Patients With Failing Mitral Surgical Rings or Bioprostheses Who Are Not Candidates for Mitral Valve Surgery.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02370511
Acronym
MITRAL
Enrollment
91
Registered
2015-02-25
Start date
2015-02-25
Completion date
2018-12-31
Last updated
2023-10-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mitral Valve Disease

Brief summary

The purpose of this trial is to establish the safety and feasibility of the Edwards SAPIEN XT™and SAPIEN 3™ device and delivery systems in patients with severe symptomatic calcific mitral valve disease with severe mitral annular calcification who are not candidates for standard mitral valve surgery.

Detailed description

Design: A prospective pilot study enrolling extremely high surgical risk patients with symptomatic severe calcific mitral valve disease undergoing implantation of an Edwards Sapien XT or SAPIEN 3 valve in the mitral position. There are three arms in this study evaluating three separate patient populations described below: * Native Mitral Valve with severe Mitral Annular Calcification (MAC): Patients with symptomatic severe disease of a native mitral valve due to severe mitral annular calcification. * Valve-in-Ring: Patients with symptomatic failing surgical rings resulting in severe mitral regurgitation or stenosis. * Valve-in-Valve: Patients with failing bioprosthetic surgical valves with severe regurgitation or stenosis The delivery approaches include: standard transeptal, modified transeptal approach with a guidewire externalized through a sheath percutaneously placed in the left ventricle, surgical trasnapical and surgical transatrial delivery approach with or without surgical resection of the anterior mitral valve (MV) leaflet (in the native mitral valve arm). The MITRAL Trial site investigative team (heart team) consists of dedicated representatives from cardiac surgery, interventional cardiology, echocardiology, neurology, study coordination and other multi-disciplinary team members consistent with a transcatheter aortic valve replacement (TAVR) model. Endpoints Most endpoints were defined following the Mitral Valve Academic Research Consortium (MVARC) recommendations with minor modifications.73 The primary safety endpoint is: technical success at exit from the cath lab • Technical success (at exit from the cath lab) is defined as: * Successful vascular and/or TA access, delivery and retrieval of the transcatheter valve delivery system * Deployment of a single valve * Correct position of transcatheter valve in the mitral annulus * Adequate performance of the prosthetic heart valve (mean mitral valve gradient (MVG) \<10 mmHg) without residual mitral regurgitation (MR) grade ≥2 (+) * No need for additional surgery or re-intervention (includes drainage of pericardial effusion) * The patient leaves the cath lab alive The primary performance endpoint is: absence of MR grade 2 (+) or greater or mean MVG ≥10 mmHg at 30 days and 1 year. Secondary safety endpoints include: Procedural success and all -cause mortality at 30 days and 1 year. * Procedural Success (30 days) in defined as: * Device success at 30 days * No device/procedure related severe adverse event (SAE's) including: death, stroke, MI or coronary ischemia requiring PCI or CABG, stage 2 or 3 AKI including dialysis, life threatening bleeding, major vascular or access complications (arterial, venous, or TA - any event requiring additional unplanned surgical or transcatheter intervention), pericardial effusion or tamponade requiring drainage, severe hypotension, heart failure or respiratory failure requiring intravenous pressors or invasive or mechanical treatments such as ultrafiltration or hemodynamic assist devices including intra-aortic balloon pump or left ventricular assist device, or prolonged intubation for ≥48 hrs, or any valve-related dysfunction, migration, thrombosis, or other complication requiring surgery or repeat intervention. * Device success is defined as: * Stroke free survival with original valve in place * No need for additional surgery or re-intervention related to the procedure, access or to the replacement valve * Proper placement and intended function of the replacement valve, including * No migration, fracture, thrombosis, hemolysis or endocarditis * No replacement valve stenosis (MV gradient \< 10 mmHg) * Replacement valve regurgitation \< 2 + (including central and paravalvular leak) and without associated hemolysis * No increase in AI from baseline (more than 1 grade) and LVOT gradient \< 20 mmHg increase from baseline Additional secondary safety and effectiveness endpoints will be evaluated at two time points: (1) acute, covering events occurring out to 30 days or hospital discharge, whichever is longer; and (2) longer-term, covering events from 31 days to 1 year, and include the following: Additional Safety Endpoints: Freedom from * all stroke and TIA (MVARC) * myocardial infarction * major vascular complication (MVARC) * life-threatening bleeding (MVARC) * mitral valve reoperation or catheter-based intervention for: valve thrombosis, valve displacement, or other valve placed procedure-related complication * hemolysis * endocarditis * moderate or severe central mitral insufficiency ≥ 2 (+), and/or moderate or severe perivalvular leak causing ≥ 2 (+) mitral insufficiency * significant mitral stenosis (mean MVG \>10 mmHg) * new permanent pacemaker insertion * new aortic valve dysfunction (difference greater than 1(+) severity compared with baseline) * new LVOT gradient ≥ 20 mmHg, or ≥ 20 mmHg increase from baseline LVOT gradient. * acute kidney injury (MVARC) * new onset atrial fibrillation * blood transfusion * access site infection * need for iatrogenic ASD closure after index procedure Additional Effectiveness Endpoints: 1. Rehospitalization at 1 year and Total days alive and out of hospital (from date of index procedure) 2. Clinical improvement per NYHA Class (from baseline) by at least 1 class. 3. Clinical improvement per Quality of Life instruments (\>10 points from baseline): (KCCQ 12) (Appendix N) 4. Clinical improvement per 6 Minute Walk Test (\> 50 meters from baseline) and 5 meter walk test. (Appendix H) 5. Mean ICU and total index procedure hospital length of stay Additional Valve Performance Endpoints: 1. Freedom from major mitral paravalvular leak 2. Improvement in hemodynamic function: mean gradient 3. Freedom from structural valve deterioration 4. Total mitral regurgitation

Interventions

Implantation of a balloon expandable Edwards SAPIEN XT or SAPIEN 3 transcatheter heart valve in the mitral position.

Sponsors

Henry Ford Hospital
CollaboratorOTHER
Mayra Guerrero
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
22 Years to No maximum
Healthy volunteers
No

Inclusion criteria

in Native Mitral Valve arm All Candidates must meet the following criteria: 1. Patient has severe calcific native mitral valve stenosis with mitral annular calcification with echocardiographically derived mitral valve area (MVA) of ≤1.5 cm2, or severe mitral regurgitation with severe mitral annular calcification and at least moderate mitral valve stenosis. Qualifying echo must be within 60 days of the date of the procedure. 2. Patient is symptomatic from mitral valve disease, as demonstrated by reported NYHA Functional Class II or greater, or symptoms during stress test. 3. The patient is at least 22 years old. 4. The heart team agrees (and verified in the case review process) that valve implantation will likely benefit the patient. 5. The heart team agrees that medical factors preclude operation, based on a conclusion that the probability of death or serious, irreversible morbidity exceeds the probability of meaningful improvement. Specifically, the STS score is ≥15% or the probability of death or serious, irreversible morbidity is ≥ 50%. The surgeons' consult notes shall specify the medical or anatomic factors leading to that conclusion and include a printout of the calculation of the STS score to additionally identify the risks in the patient (some medical factors and definitions are provided below). At least one of the cardiac surgeon assessors must have physically evaluated the patient. All patients must be approved by the Patient Selection and Procedure Management Steering Committee (at least 2 member votes, one must be a cardiac surgeon). 6. The study patient has been informed of the nature of the study, agrees to its provisions and has provided written informed consent as approved by the Institutional Review Board (IRB) of the respective clinical site. 7. The study patient agrees to comply with all required post-procedure follow-up visits including annual visits through 5 years and analysis close date visits, which will be conducted as a phone follow-up. Inclusion Criteria in Valve-in-Ring arm All Candidates must meet the following criteria: 1. Patient has a failing surgical ring in the mitral position with severe mitral regurgitation or stenosis (echocardiographically derived mitral valve area \[MVA\] of ≤1.5 cm2. Qualifying echo must be within 60 days of the date of the procedure. 2. Patient is symptomatic from mitral valve disease, as demonstrated by reported NYHA Functional Class II or greater, or symptoms during stress test, or severe hemolytic anemia requiring blood transfusions and no other cause of hemolytic anemia is found after extensive work up. Inclusion Criteria items #3 to 7 will be the same as in Native MV arm described above Inclusion Criteria in Valve-in-Valve arm All Candidates must meet the following criteria: 1. Patient has a failing surgical bioprosthesis in the mitral position with severe mitral regurgitation or stenosis with echocardiographically derived mitral valve area (MVA) of ≤1.5 cm2. Qualifying echo must be within 60 days of the date of the procedure. 2. Patient is symptomatic from mitral valve disease, as demonstrated by reported NYHA Functional Class II or greater, or symptoms during stress test. Inclusion Criteria items #3 to 7 will be the same as in Native MV arm described above

Exclusion criteria

Candidates will be excluded from the study if any of the following conditions are present: 1. Heart Team assessment of operability (the heart team considers the patient is a surgical candidate). 2. Evidence of an acute myocardial infarction ≤ 1 month (30 days) before the intended treatment \[defined as: Q wave MI, or non-Q wave MI with total CK elevation of CK-MB ≥ twice normal in the presence of MB elevation and/or troponin level elevation (WHO definition)\]. 3. Mitral annulus is not calcified (only applies to patients included in Native MV arm). 4. Complex untreated coronary artery disease: 1. Unprotected left main coronary artery 2. Syntax score \> 32 (in the absence of prior revascularization) 5. Any therapeutic invasive cardiac procedure resulting in a permanent implant that is performed within 30 days of the index procedure (unless part of planned strategy for treatment of concomitant coronary artery disease). Implantation of a permanent pacemaker is not excluded. 6. Any patient with a balloon valvuloplasty (BMV) within 30 days of the procedure (unless BMV is a bridge to procedure after a qualifying ECHO). 7. Patients with planned concomitant surgical or transcatheter ablation for Atrial Fibrillation. 8. Leukopenia (WBC \< 3000 cell/mL), acute anemia (Hgb \< 9 g/dL), Thrombocytopenia (Plt \< 50,000 cell/mL). 9. Hypertrophic obstructive cardiomyopathy (HOCM). 10. Hemodynamic or respiratory instability requiring inotropic support, mechanical ventilation or mechanical heart assistance within 30 days of screening evaluation. 11. Need for emergency surgery for any reason. 12. Severe ventricular dysfunction with LVEF \< 20%. 13. Echocardiographic evidence of intracardiac mass, thrombus or vegetation. 14. Active upper GI bleeding within 3 months (90 days) prior to procedure. 15. A known contraindication or hypersensitivity to all anticoagulation regimens, or inability to be anticoagulated for the study procedure. 16. For patients enrolled in the Native MV arm: Native mitral annulus size \< 275 mm2 or \> 740 mm2 as measured by CT scan. For patients in Valve-in-Ring arm: surgical ring with a true mean internal diameter ≤18 mm or ≥ 29 mm or an area \< 275 mm2 or \> 740 mm2 as measured by CT scan. Caution recommended in: * Incomplete bands due to risk of paravalvular leak and risk of LVOT obstruction. Careful measurements by CT and CT-guided procedural planning is recommended. * Non-circular rigid or semi-flexible rings (e.g., D-shaped, saddle shaped, etc) due to risk of para-valvular leak and/or out of round or incomplete valve expansion. For patients in Valve-in-Valve arm: surgical bioprosthesis with a true internal diameter ≤18 mm or ≥ 29 mm 17. Clinically (by neurologist) or neuroimaging confirmed stroke or transient ischemic attack (TIA) within 6 months (180 days) of the procedure. 18. Estimated life expectancy \< 24 months (730 days) due to carcinomas, chronic liver disease, chronic renal disease or chronic end stage pulmonary disease. 19. Expectation that patient will not improve despite treatment of mitral stenosis 20. Active bacterial endocarditis within 6 months (180 days) of procedure.

Design outcomes

Primary

MeasureTime frameDescription
Technical Success at Exit From the Cath Lab.30 daysNumber of subject to achieve technical success (at exit from cath lab) is defined as: * Successful vascular delivery and retrieval of transcatheter valve delivery system * Deployment of single valve * Correct position of transcatheter valve * Adequate performance of prosthesis (MVA \> 1.5 cm2) without residual MR grade ≥2 (+) * No need for additional surgery or re-intervention * Patient leaves cath lab alive
Absence of MR Grade 2 (+) or Greater30 days and 1 yearNumber of subjects to have absence of MR grade 2 (+) or greater assessed with echocardiography. MR severity grading system ranging from Grade 1=mild; Grade 4=severe.
Mitral Valve Gradient (MVG)30 days and 1 yearMVG assessed by echocardiography measured in mmHg

Secondary

MeasureTime frameDescription
Procedural Success30 daysNumber of subject to have procedural success as defined as no device/procedure related SAE's including: death, stroke, MI or coronary ischemia requiring PCI or CABG, stage 2 or 3 AKI including dialysis, life threatening bleeding, major vascular or access complications (arterial, venous, or TA - any event requiring additional unplanned surgical or transcatheter intervention), pericardial effusion or tamponade requiring drainage, severe hypotension, heart failure or respiratory failure requiring intravenous pressors or invasive or mechanical treatments such as ultrafiltration or hemodynamic assist devices including intra-aortic balloon pump or left ventricular assist device, or prolonged intubation for ≥48 hrs, or any valve-related dysfunction, migration, thrombosis, or other complication requiring surgery or repeat intervention.

Countries

United States

Participant flow

Participants by arm

ArmCount
Native Mitral Valve With Severe MAC
Patients with symptomatic severe calcific native mitral valve disease with severe mitral annular calcification who have extremely high surgical risk for standard surgical mitral valve replacement, will undergo transcatheter mitral valve replacement. Transcatheter Mitral Valve Replacement: Implantation of a balloon expandable Edwards SAPIEN XT or SAPIEN 3 transcatheter heart valve in the mitral position.
31
Valve-in-Ring
Patients with symptomatic failing surgical rings resulting in severe mitral regurgitation or stenosis will undergo transcatheter mitral valve replacement (valve-in-ring). Transcatheter Mitral Valve Replacement: Implantation of a balloon expandable Edwards SAPIEN XT or SAPIEN 3 transcatheter heart valve in the mitral position.
30
Valve-in-Valve
Patients with symptomatic failing surgical bioprostheses resulting in severe mitral regurgitation or stenosis will undergo transcatheter mitral valve replacement (Valve-in-valve). Transcatheter Mitral Valve Replacement: Implantation of a balloon expandable Edwards SAPIEN XT or SAPIEN 3 transcatheter heart valve in the mitral position.
30
Total91

Withdrawals & dropouts

PeriodReasonFG000FG001FG002
Overall StudyDeath1071
Overall StudyLost to Follow-up040
Overall StudyWithdrawal by Subject200

Baseline characteristics

CharacteristicNative Mitral Valve With Severe MACTotalValve-in-ValveValve-in-Ring
Age, Continuous74.5 years75.5 years77.5 years71.5 years
Ethnicity (NIH/OMB)
Hispanic or Latino
1 Participants3 Participants0 Participants2 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
30 Participants88 Participants30 Participants28 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants0 Participants0 Participants0 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
0 Participants2 Participants1 Participants1 Participants
Race (NIH/OMB)
Black or African American
0 Participants6 Participants4 Participants2 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants0 Participants0 Participants0 Participants
Race (NIH/OMB)
White
31 Participants83 Participants25 Participants27 Participants
Region of Enrollment
United States
31 participants91 participants30 participants30 participants
Sex: Female, Male
Female
22 Participants52 Participants19 Participants11 Participants
Sex: Female, Male
Male
9 Participants39 Participants11 Participants19 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
EG002
affected / at risk
deaths
Total, all-cause mortality
10 / 317 / 301 / 30
other
Total, other adverse events
17 / 3112 / 306 / 30
serious
Total, serious adverse events
18 / 3113 / 308 / 30

Outcome results

Primary

Absence of MR Grade 2 (+) or Greater

Number of subjects to have absence of MR grade 2 (+) or greater assessed with echocardiography. MR severity grading system ranging from Grade 1=mild; Grade 4=severe.

Time frame: 30 days and 1 year

Population: For MAC arm at 30 days 5 patients died and one withdrew consent and at 1 yr 5 additional patients died, 1 additional withdrew consent and 1 additional did not complete 1 yr follow up. For Valve-in-Ring arm at 30 days 2 patients died and at 1 yr 5 additional patients died, 1 patient lost to follow up and 3 did not complete 1 yr follow up. For Valve-in-Valve arm 1 patient died. Data was not collected or analyzed for these patients.

ArmMeasureGroupValue (COUNT_OF_PARTICIPANTS)
Native Mitral Valve With Severe MACAbsence of MR Grade 2 (+) or Greater30 days23 Participants
Native Mitral Valve With Severe MACAbsence of MR Grade 2 (+) or Greater1 year18 Participants
Valve-in-RingAbsence of MR Grade 2 (+) or Greater30 days28 Participants
Valve-in-RingAbsence of MR Grade 2 (+) or Greater1 year19 Participants
Valve-in-ValveAbsence of MR Grade 2 (+) or Greater30 days29 Participants
Valve-in-ValveAbsence of MR Grade 2 (+) or Greater1 year29 Participants
Primary

Mitral Valve Gradient (MVG)

MVG assessed by echocardiography measured in mmHg

Time frame: 30 days and 1 year

Population: For MAC arm at 30 days 5 patients died and one withdrew consent and at 1 yr 5 additional patients died, 1 additional withdrew consent and 1 additional did not complete 1 yr follow up. For Valve-in-Ring arm at 30 days 2 patients died and at 1 yr 5 additional patients died, 1 patient lost to follow up and 3 did not complete 1 yr follow up. For Valve-in-Valve arm 1 patient died. Data was not collected or analyzed for these patients.

ArmMeasureGroupValue (MEDIAN)
Native Mitral Valve With Severe MACMitral Valve Gradient (MVG)30 days6.0 mmHg
Native Mitral Valve With Severe MACMitral Valve Gradient (MVG)1 year6.1 mmHg
Valve-in-RingMitral Valve Gradient (MVG)30 days7.6 mmHg
Valve-in-RingMitral Valve Gradient (MVG)1 year6.0 mmHg
Valve-in-ValveMitral Valve Gradient (MVG)30 days6.0 mmHg
Valve-in-ValveMitral Valve Gradient (MVG)1 year6.6 mmHg
Primary

Technical Success at Exit From the Cath Lab.

Number of subject to achieve technical success (at exit from cath lab) is defined as: * Successful vascular delivery and retrieval of transcatheter valve delivery system * Deployment of single valve * Correct position of transcatheter valve * Adequate performance of prosthesis (MVA \> 1.5 cm2) without residual MR grade ≥2 (+) * No need for additional surgery or re-intervention * Patient leaves cath lab alive

Time frame: 30 days

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
Native Mitral Valve With Severe MACTechnical Success at Exit From the Cath Lab.23 Participants
Valve-in-RingTechnical Success at Exit From the Cath Lab.20 Participants
Valve-in-ValveTechnical Success at Exit From the Cath Lab.30 Participants
Secondary

Procedural Success

Number of subject to have procedural success as defined as no device/procedure related SAE's including: death, stroke, MI or coronary ischemia requiring PCI or CABG, stage 2 or 3 AKI including dialysis, life threatening bleeding, major vascular or access complications (arterial, venous, or TA - any event requiring additional unplanned surgical or transcatheter intervention), pericardial effusion or tamponade requiring drainage, severe hypotension, heart failure or respiratory failure requiring intravenous pressors or invasive or mechanical treatments such as ultrafiltration or hemodynamic assist devices including intra-aortic balloon pump or left ventricular assist device, or prolonged intubation for ≥48 hrs, or any valve-related dysfunction, migration, thrombosis, or other complication requiring surgery or repeat intervention.

Time frame: 30 days

Population: For MAC arm 1 withdrew consent data was not collected or analyzed.

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
Native Mitral Valve With Severe MACProcedural Success16 Participants
Valve-in-RingProcedural Success22 Participants
Valve-in-ValveProcedural Success28 Participants