Skip to content

KYMA Device: External Measure of Thoracic Fluid and Vital Signs

KYMA Device: External Measure of Thoracic Fluid and Vital Signs

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02369042
Acronym
Ease
Enrollment
17
Registered
2015-02-23
Start date
2014-10-31
Completion date
2017-04-19
Last updated
2017-07-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Congestive Heart Failure(CHF)

Brief summary

External measure of thoracic fluid content (TFC) combined with vital signs (HR,respiratory rate(RR), posture and movements) using the technology developed by Kyma Medical Technologies while tracking clinical changes in acute in-hospital and chronic outpatient heart failure patients.

Detailed description

This is a prospective, single center, non-randomized study designed to correlate Kyma measurements and in-hospital parameters as well as the changes in TFC and vital signs with clinical changes in the outpatient setting for 60 days post-discharge. The patient and hospital study personnel will be blinded to the Kyma data captured by the device. No intervention will be performed on the patient based on the Kyma device data, this is an observational study. The goals of the study are: 1. Follow thoracic fluid and vital signs in acute, hospitalized heart failure(HF) patients with evidence of volume overload to evaluate this combined parameter in relation to decongestion (time to clear lung auscultation or clearing of congestion on chest x-ray or decrease in BNP by 50%), clinical symptoms, physical exam, and biomarker results. 2. Evaluate the relationship between lung decongestion as externally measured and hemodynamic parameters as measured by pulmonary artery catheter in a subset of patients 3. Correlate changes in thoracic fluid content and vital signs with clinical changes in the outpatient setting for 60 days post-discharge. 4. Evaluate the feasibility of implementing a physician-directed, patient- managed model of diuretic and vasodilator adjustment. Patients will be approached for enrollment within 24 hours of presentation to the hospital. The Kyma device will be applied to the patient. Data will be automatically collected by the device: TFC will be measured every 30 minutes and vital signs will be measured several times an hour. Information collected at baseline by the study coordinators will include medications, lab work (CBC, Chemistry, BNP), ejection fraction(EF), weight, vital signs, and lung auscultation for both Cohorts. Cohorts I and II may be enrolled concurrently. For patients enrolled in Cohort I, PA readings will be recorded at baseline and 3 times daily until the pulmonary artery(PA) catheter is removed. While hospitalized, all patients will have daily weights, intake/output, Physical Exams(edema, jugular venous distention(JVP), lung exam) and vital signs will be recorded twice daily. Lab results will be recorded as well as any changes in medication. After hospital discharge, the patients will wear the Kyma device for an additional 60 days. Patients will be contacted by telephone at 10 days, 30 days, and 60 days post-discharge for weight measurements, medication changes, and assessment of any Office Visits, or ER/Hospitalizations for SOB. The Minnesota Living with Heart Failure Questionnaire will be administered at hospital discharge and 30 and 60 days post-discharge.

Interventions

DEVICEKyma Device u-Cor System

The Kyma uCor system externally measures thoracic fluid content, heart rate, respiratory rate, posture and movement. The system includes a flat antenna that is attached to the patient's torso with a bandage-like sticker. The antenna transmits radio waves and receives their reflections from the body for several seconds every few hours throughout the day.The data is recorded and collected then compared to traditional clinical parameters.

Sponsors

The Christ Hospital
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
TRIPLE (Subject, Caregiver, Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Cohort I 1. Men or women over 18 years of age 2. Admitted for primary diagnosis of HF 3. Already assigned for indwelling PA catheter monitoring 4. BNP \> 400 5. Two of the following: edema, JVP\>7cm, rales 6. Currently being assessed with clinically indicated hemodynamic monitoring Cohort II 1. Men or women over 18 years of age 2. Admitted with the primary diagnosis of HF 3. BNP \> 400 4. Two of the following: edema, JVP\> 7cm, rales 5. Patients with or without hemodynamic monitoring in use

Exclusion criteria

Cohort I and II 1. Patients with allergies or skin sensitivities to electrode hydrogel and/or acrylic based adhesive 2. Pregnant women

Design outcomes

Primary

MeasureTime frameDescription
Validate the ability of externally monitored thoracic fluid content as a measure of HF.60 daysAccomplished by comparing the data measured by the Kyma Device(HR, RR, thoracic fluid content) with the same clinical data collected while in the hospital.

Secondary

MeasureTime frameDescription
Assess the effectiveness of remote monitoring in detecting outpatient decompensation.60 daysCompare the data collected by the Kyma Device (HR, RR, movement, thoracic fluid content) to any clinical changes related to HF in the outpatient setting.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026