Skip to content

Utility of Thenar Near Infrared Spectroscopy (NIRS) in Pediatric Patients With Heart Failure

Utility of Thenar Near Infrared Spectroscopy (NIRS) in Pediatric Patients With Heart Failure

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02368041
Enrollment
130
Registered
2015-02-20
Start date
2015-05-01
Completion date
2027-05-10
Last updated
2026-03-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure

Brief summary

This is a single-center, non-randomized study.The study staff will use the InSpectraTM tissue oxygen saturation (StO2) monitor manufactured by Hutchinson Technology to measure baseline StO2 levels after applying the noninvasive probe to the thenar eminence. After a stable reading is obtained, a blood pressure cuff will be inflated 40 mmHg above the obtained systolic pressure and the rate of desaturation (Rdes; % × sec-1) will be recorded. After 3 minutes or once the StO2 level comes to zero (whichever is earlier), the cuff pressure will be released and the rate of reperfusion (Rres; % × sec-1) will be measured. The investigators hypothesize that heart failure in children causes a baseline lower thenar tissue oxygen saturation (StO2), a faster rate of desaturation (Rdes) and a prolonged rate of reperfusion (Rres). The investigators also hypothesize that these changes will correlate with the severity of heart failure. The results of this study will provide groundwork for studies looking at correlation of therapy modification based on the combination thenar StO2 and clinical presentation.

Detailed description

Heart failure patients seen in the Pediatric Cardiology Congenital Heart Center will be enrolled into the study after obtaining informed consent on the day of their evaluation. The primary pediatric cardiologist following the patient will evaluate the need for regular investigations like blood work, electrocardiogram and echocardiogram. The study staff will use the InSpectraTM tissue oxygen saturation (StO2) monitor manufactured by Hutchinson Technology to measure the baseline StO2 level after applying the noninvasive probe to the thenar eminence. After a stable reading is obtained a blood pressure cuff will be inflated 40 mmHg above the obtained systolic pressure and the rate of desaturation (Rdes; % × sec-1) will be recorded. After 3 minutes or once the StO2 level comes to zero (whichever is earlier), the cuff pressure will be released and the rate of reperfusion (Rres; % × sec-1) will be measured. Similar measurements will be obtained from an otherwise healthy cohort of children who present to the Pediatric Cardiology Congenital Heart Center for evaluation of a heart murmur or chest pain. The patient's treating physician and care providers will be blinded to the study test results. All clinical care will be at the discretion of the patient's treating physicians. Only StO2 levels will be obtained using the non-invasive probe placed on the thenar eminence for the purpose of the study.

Interventions

DEVICEInSpectraTM StO2 monitor

InSpectraTM StO2 monitor manufactured by Hutchinson Technology Inc. to measure the baseline StO2 level after applying the noninvasive probe to the thenar eminence. After a stable reading is obtained a blood pressure cuff will be inflated 40 mmHg above the obtained systolic pressure and the rate of desaturation (Rdes; % × sec-1) will be recorded. After 3 minutes or once the StO2 level comes to zero, whichever is earlier the cuff pressure will be released instantaneously and the rate of reperfusion (Rres; % × sec-1) will be measured. The measurement will be continued until the StO2 returns to the baseline value.

Sponsors

University of Florida
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
No minimum to 25 Years
Healthy volunteers
Yes

Inclusion criteria

* Heart failure patients under 25 years of age with a diagnosis of cardiomyopathy, myocarditis or univentricular palliation for congenital heart disease who are stable on their medical management will be enrolled.

Exclusion criteria

1. Patients presenting with acute deterioration in clinical status 2. Patients with active infection 3. Patients with autoimmune vasculitis disorder 4. Patients with limb deformities and painful disorders of extremities 5. Patients with underlying bone disorders, (e.g. osteogenesis imperfecta) 6. Patients with severe anemia (Hb \<7g/dL) 7. Patients with peripheral vascular disease which can alter the microcirculation

Design outcomes

Primary

MeasureTime frameDescription
Baseline StO2 percentageDay 1The study staff will use the InSpectraTM StO2 monitor manufactured by Hutchinson Technology to measure the baseline StO2 level after applying the noninvasive probe to the thenar eminence

Secondary

MeasureTime frameDescription
Occlusion- rate of desaturation (Rdes) of StO2 levelsDay 1After a stable baseline reading is obtained a blood pressure cuff will be inflated 40 mmHg above the obtained systolic pressure and the rate of desaturation (Rdes; % × sec-1) will be recorded for 3 min or until the StO2 level comes to zero (whichever is earlier).
Recovery- rate of reperfusion (Rres) of StO2 levelsDay 1After 3 minutes from occlusion or once the StO2 level comes to zero (whichever is earlier), the cuff pressure will be released and the rate of reperfusion (Rres; % × sec-1) will be measured for approximately 3 min.

Countries

United States

Contacts

CONTACTDipankar Gupta, MD
dgupta@ufl.edu352-273-7770
PRINCIPAL_INVESTIGATORDipankar Gupta, MD

University of Florida