Post Marketing Surveillance of the CentrosFLO™ Tunneled IJ Catheter

Post Marketing Surveillance of the CentrosFLO™ Tunneled IJ Catheter for Dialysis

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02349308
Acronym
MCENPS
Enrollment
10
Registered
2015-01-28
Start date
2013-10-31
Completion date
2015-07-31
Last updated
2015-09-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pain; Dialysis Catheter

Brief summary

The purpose of this study is to demonstrate the stability of blood flow with the CentrosFLO catheter, during intermittent dialysis over a period of 6 months after placement.

Detailed description

The CentrosFLO™ Tunneled Dialysis Catheter is a 15F dual-lumen, double-D shaped catheter similar to other split tip catheters in the market: outflow (arterial) and return (venous) lumens that separate, a subcutaneous Dacron® cuff, extension sets with clamps and caps, and construction from Carbothane® material. The CentrosFLO™ catheter contains two small pressure-relief holes near the tips. The main difference of the CentrosFLO catheter is in the design of the tip. Current split tip catheters have two free ends that diverge, but are each essentially straight segments. In the CentrosFLO catheter the arterial lumen bends in an arc back towards the venous lumen, and the venous lumen bends towards the arterial lumen. As a result, the catheter has two curved surfaces that will rest against the vena cava wall to automatically center the catheter within the vein. The contact points of the catheter against the vena cava wall should be smaller and more disperse than with current straight-tip or split catheters. The following drawing demonstrates the design of the catheter, showing the current recommendation that the arterial port always be to the left. The goal of the study is to demonstrate the stability of blood flow with the CentrosFLO catheter, during intermittent dialysis over a period of 6 months after placement. The investigators plan to enroll 10 patients in the study.

Interventions

DEVICECentrosFLO Long Term Hemodialysis Catheter

Sponsors

Merit Medical Systems, Inc.
Lead SponsorINDUSTRY

Study design

Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Adult patients who are initiating or continuing in-center intermittent hemodialysis who are scheduled to receive a tunneled dialysis catheter in the right or left internal jugular vein * The patients may have had a prior tunneled catheter for dialysis in the right IJ site. * Patients will be expected to need use of the catheter for more than 45 days

Exclusion criteria

* Patients in whom the catheter is planned to be placed into the same site as an existing catheter, by over-the-wire catheter exchange * Patients unable to give informed consent

Design outcomes

Primary

MeasureTime frameDescription
Primary Endpoint: Stability of hydraulic resistance measured as normalized arterial pressure in mmHg/mL/min by dialysis flow meter weekly for up to six months1.5 yearsStability of hydraulic resistance measured as normalized arterial pressure in mmHg/mL/min by dialysis flow meter weekly for up to six months

Secondary

MeasureTime frameDescription
Secondary Endpoint: Incidence of patency failure defined as blood flow rate below 300 mL/min or removal of catheter for failure of flow at any time during the study.1.5 yearsIncidence of patency failure defined as blood flow rate below 300 mL/min or removal of catheter for failure of flow at any time during the study.

Countries

United States

Outcome results

None listed