Skip to content

MiniMed 640G System User Evaluation With the Question of Reducing the Rate of Hypoglycemia

Prevention of Hypoglycaemia Using the Minimed®640G System

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02325193
Enrollment
24
Registered
2014-12-24
Start date
2015-03-31
Completion date
2016-03-31
Last updated
2016-03-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Type 1 Diabetes

Brief summary

The Minimed®640G system (MM640G) consists of a combination of insulin and glucose sensor for continuous glucose monitoring (CGM). Here, the glucose sensor transmits not only the continuous glucose data on the display of insulin pump but, in the case of hypoglycemia also interrupt their insulin delivery of pump. In the currently available system Paradigm®VEO, the interruption takes place at a settled threshold level. In difference in the new system MM640G the shutdown algorithm can already be proactive and help avoid hypoglycemia completely. The so called PLGM algorithm (predictive low glucose management) should be tested in the user evaluation. The main objective is to answer the question of reducing the rate of hypoglycemia by application of the new PLGM algorithm. Included are a total of 24 patients, aged 1-21 years, in three pediatric diabetes centers.

Detailed description

In the first phase of two weeks, the sensor-augmented pump therapy (SaP) is carried out without these interruption PLGM algorithm. In a second phase for 6 weeks, the PLGM function is set. Both phases are compared in terms of the rate of hypoglycemia, the time spent and the area under the curve (AUC) glucose range (values \<70 mg / dl (3.9 mmol / l)).

Interventions

DEVICEMinimed®640G system

Sensor augmented insulin therapy with and without use of Predictive low glucose management (PLGM)

Sponsors

Medtronic International Trading Sarl
CollaboratorINDUSTRY
Kinderkrankenhaus auf der Bult
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
1 Years to 21 Years
Healthy volunteers
No

Inclusion criteria

* type 1 diabetes, diagnosed since 12 month at least * continuous subcutaneous insulin infusion (CSII) since 3 month at least * stable outcome since 3 month at least * willingness of patients/ parents to wear a glucose sensor for 2 month * willingness of patients/ parents to use the Minimed®640G system * willingness of patients/ parents to complete a diary * willingness of patients/ parents to comply the requirements of the study protocol

Exclusion criteria

* longer absence of the patients (not able to attend the study visits) * subject with allergy of sensor or specific sensor components * communication problems * significant history of eating disorder, anorexia, bulimia * pregnancy * significant history of drug abuse or/ and alcoholism * patient do not want to attend the trial * missing informed consent

Design outcomes

Primary

MeasureTime frame
average AUC/day in hypoglycaemic range < 70mg/dl (3,9mmo/l)6 weeks

Secondary

MeasureTime frame
Number of PLGM activities6 weeks

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026