Skip to content

Unilateral Sequential Sympathectomy for Palmar Hyperhidrosis

Unilateral Sequential Versus Bilateral Simultaneous Sympathectomy for Palmar Hyperhidrosis: a Study of 407 Cases.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02321332
Acronym
ETS
Enrollment
400
Registered
2014-12-22
Start date
2010-06-30
Completion date
2013-06-30
Last updated
2014-12-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Palmar Hyperhidrosis

Keywords

Palmar hyperhidrosis, Endoscopic thoracic sympathectomy

Brief summary

Comparison between unilateral sequential and bilateral simultaneous endoscopic thoracic sympathectomy for palmar hyperhidrosis on patients outcomes notably compensatory hyperhidrosis.

Interventions

PROCEDUREunilateral sequential endoscopic thoracic symapthectomy.

Patients underwent unilateral T2-T3 ganglionectomy of the dominant side followed by T2-T3 ganglionectomy of the other side after 2 months interval.

PROCEDUREbilateral simultaneous endoscopic thoracic symapthectomy

Patients underwent bilateral simultaneous T2-T3 ganglionectomy using thoracoscopic approach.

Sponsors

Tmaer Youssef Mohamed
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
ALL
Age
8 Years to 50 Years
Healthy volunteers
No

Inclusion criteria

* Patients suffering palmar hyperhidrosis

Exclusion criteria

* Patients with pleural adhesions, bleeding diathesis, local infection or previous operation for hyperhidrosis

Design outcomes

Primary

MeasureTime frameDescription
Number of participants developing compensatory hyperhidrosis (reflex sweating) following sympathectomy.one yearNumber pf patients developing compensatory hyperhidrosis (reflex sweating) following sympathectomy. Compensatory hyperhidrosis was graded as severe when the patient mentioned that sweating interfered with his or her normal activity, moderate when the patient indicated that his or her sweating was not bothersome and mild when the patient did not mention dampness or made only a brief reference.

Secondary

MeasureTime frameDescription
Number of patients who will be satisfied or unsatisfied regarding the procedure.one yearwe measure patient satisfaction regarding the procedure by asking the patients to rate their level of satisfaction as very satisfied, somewhat satisfied, somewhat dissatisfied and very dissatisfied. Patients were considered satisfied if they reported being very satisfied or somewhat satisfied.

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026